Connection to the water system
Please follow water connection instructions below:
-
install the T-connection with 6 bar* safety valve and the drain valve to the fitting of
cold water inlet [ZW]. It’s forbidden to install a cut-off valve (or any flow reducer)
between the tank and the safety valve and on its outlet. The safety valve must be
installed in such a place as to quickly let you notice the outgoing water,
-
install the cylinder equipped with the safety valve to the water system,
-
install the cut-off valve on cold water supply pipe.
Hot water outlet should be led to the connections in the upper part of the cylinder. Every
cylinder is equipped with connection intended for its installation to the DHW circulation.
The buffer tank can be assembled in the heating system:
-
open system according to the current standards,
-
closed system according to the current standards.
*Please note: use the safety valve matched to the heat’s source. Installing a safety valve
with inadequate capacity can result for excessive pressure increase in the cylinder and
as a result a leakage. In this case, warranty does not cover damage caused.