18
Connection to the central heating system
Cylinder must be fitted to the central heating system by pipe unions 1¼″. A cut-off
valves must be installed before the pipe unions. A flow rate of heating water must be
high enough to maximise cylinder efficiency (see ‚Technical data table). It concerns the
forced circulation installation (with a central heating water pump).
Model SWVPC is equipped in double heating coil.
Description of device
Cylinder SWVPC is a device with double tank intended to heating medium system with
heat pump.
The upper tank is enamelled with double heating coil, intened to prepare domestic hot
water. In the lower part, there is a buffer with unenamelled tank, anti-corrosion inhibitor
protected for transport.
Buffer tank is intended for heating water and/or cold storage with co-opeartion with
central heating boilers and heat pumps. Additionally, buffer tanks may also perform the
following function: divider (hydraulic clutch), hydraulic seperator, heating circuit from
the boiler room. Can’t work with domestic hot water.