20
Sensor exhibits
The motion sensor exhibits the most dependable detection
behavior when the detection range is passed through trans-
versally
2
and not frontally
3
to the motion detector. (see
Illustrations)
Elektrischer Anschluss
Strip the insulation from the connecting wires for approx.
6-8 mm
4
and connect as follows:
See wiring diagrams
5
.
•
Phase L (black) on terminal L.
•
Neutral wire N (blue) on terminal 2 x N.
•
Connecting/lamp wire (brown) on terminal L↑.
•
For remote switching (manual override / Manual ON),
connect the external button to terminal T.
•
For Master/Slave function, connect the terminals P of
the motion sensors with each other.
Connection of consumers
High starting currents severely reduce the useful life of relays.
For this, follow the technical instructions of the lamp or light
manufacturer. High inductive loads should be switched by
means of an additional relay or an additional contactor.
2
3
L
N
N
L
T
P
L
L
IC
6-8MM
4
5
GB