28
Technical data
Connection equipment:
Basic wiring: 3 wires (L, N, connection for consumers) Manual ON by means of button
activation: 4 wires (L, N, connection for consumers, button connection)
Connection type:
screw terminals
Settings:
ON: permanent ON for 2h
OFF: permanent OFF
AUTO: automatic
Switch-off warning:
≤ 15 sec.: 1x brief tone
≤ 10 sec.: 2x brief tones
≤ 5 sec.: 3x brief tones.
Fuse:
safety fuse T 10 A / 250 V. Dimensions (5 x 20) mm
Switching capacity:
max. 1000 W (resistive load)
Incandescent lamp:
max. 2000 W
Halogen lamp:
max. 1200 W
Fluorescent lamp:
max. 900 VA / 100 μF / (series compensated)
Low-voltage halogen lamp load:
1000 VA
Energy-saving lamps:
max. 600 VA
LED lamps:
max. 500 VA
Optional RC component (2915.0004.3): 100 nF / 100 Ω. Parallel connected to the inducted load.
Dimensions:
(50x50x65) mm
Operating temperature:
0 °C --> +45 °C
Degree of protection:
IP 40
GB