Installation
Instructions
Installation Instructions
Please observe the described hints in the “Safety Instructions”
chapter and the specification listed in the “Technical Data”
chapter.
Instruction for Mounting
Please take into consideration the needed free space on the
interface side, before you install the monitor into an industrial
cabinet, an instrument panel or other cabinets.
For detailed information about the available interfaces refer to the
Important Instructions!
The installation of the KFM19_e may only be carried out by
qualified personnel.
Ensure there is sufficient air circulation around the device when
installing the KFM19_e.
The openings for the device cooling (on upper and bottom side)
must not be obstructed. Blocked air openings, can cause
overheat of the monitor.
When installing KFM19_e into an industrial cabinet, leave at least
5 cm of free space around the unit to prevent the device from
possibly overheating!
The 19” industrial cabinet must stand firmly in place.
If further stabilisation is necessary, then bolt the industrial cabinet
to the floor or anchor it on the wall.
The voltage feeds must not be overloaded. Adjust the cabling and
the external overcharge protection to correspond with the
electrical values indicated on the type label.
The type label is located on the left side of the monitor.