Installing the Board 

3-35 

3.5.3.3. Floppy 

Disk 

Interface 

Signal 

Pin Assignation  

Description 

FD:DRVEN 0-1# 

E7, A8 

Drive 0-1 density select 

FD:INDEX# B8 

Index 

FD:MTR 0-1# 

C8, A9 

Motor 0-1 enable 

FD:DS 0-1# 

E8, D8 

Drive 0-1 select 

FD:DIR# B9 

Direction 

FD:STEP# C9 

Step 

pulse 

FD:WDATA# 

D9 

Write disk data 

FD:WGATE# E9 

Write 

gate 

FD:TRK0# A10 

Track 

FD:WRTPRT# B10 

Write 

protected 

FD:RDATA# 

C10 

Read disk data 

FD:HDSEL# D10 

Head 

select 

FD-DSKCHG# E10 

Disk 

change 

 

3.5.3.4. Serial 

Port 

Signal 

Pin Assignation  

Description 

COM2:DCD 

A11 

Data Carrier Detect 

COM2:RXD C11 

Receive 

Data 

COM2:DSR 

D11 

Data Set Ready 

COM2:TXD E11 

Transmit 

Data 

COM2:RTS 

A12 

Ready To Send 

COM2:CTS 

B12 

Clear To Send 

COM2:RI C12 

Ring 

Indicator 

COM2:DTR E12 

Data 

Terminal 

Ready 

 

3.5.3.5. Serial 

Port 

Signal 

Pin Assignation  

Description 

COM1:DCD 

A13 

Data Carrier Detect 

COM1:RXD C13 

Receive 

Data 

COM1:DSR 

D13 

Data Set Ready 

COM1:TXD E13 

Transmit 

Data 

COM1:RTS 

A14 

Ready To Send 

COM1:CTS 

B14 

Clear To Send 

COM1:RI C14 

Ring 

Indicator 

COM1:DTR E14 

Data 

Terminal 

Ready 

 

Содержание cPCI-MXS64

Страница 1: ...4 bit System Processor Technical Reference Manual Version 1 4 February 2003 Note The latest releases of the Technical Reference Manuals are available at ftp ftp kontron ca Support Product_Manuals Ref...

Страница 2: ...with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will...

Страница 3: ...ication of information or the use of products described herein This document may contain information or refer to products protected by the copyrights or patents of others and does not convey any licen...

Страница 4: ...of classification of information Excellent Satisfactory Fair Poor Comments _____________________________________________________________________________ ______________________________________________...

Страница 5: ...ADDITIONAL COMMENTS...

Страница 6: ...s instructions ATTENTION Il y a danger d explosion s il y a remplacement incorrect de la batterie Remplacer uniquement avec une batterie du m me type ou d un type quivalent recommand par le constructe...

Страница 7: ...e board this is the minimum required to see if the board is working If you still are not able to start up your system please refer to the emergency Procedure in the Appendix Section If you still are n...

Страница 8: ...vices Do not handle or store devices near strong electrostatic electromagnetic magnetic or radioactive fields Power Supply Before any installation or setup ensure that the board is unplugged from powe...

Страница 9: ...6 1 5 Compatibility with other KONTRON Products 1 7 1 6 Mezzanine Card Concept 1 8 1 6 1 Kontron s Mezzanine Concept 1 9 1 6 2 PMC Concept 1 9 1 6 3 CompactFlash Feature 1 9 2 ONBOARD FEATURES 2 1 2 1...

Страница 10: ...eset 2 8 2 9 1 2 Front Plate Configuration 2 9 2 9 2 Serial Port 2 2 9 2 9 3 Serial Port 3 2 10 2 9 3 1 Infrared Mode 2 11 2 9 3 2 RS 232 Protocol 2 11 2 9 3 3 RS 422 Protocol 2 11 2 9 3 4 RS 485 Prot...

Страница 11: ...Onboard Interconnectivity 3 8 3 2 1 cPCI MXS64 Block Diagram 3 8 3 2 2 Mobile Pentium II III Processor 3 9 3 2 3 North Bridge Chipset 3 9 3 2 4 21154 PCI to PCI Bridge 3 10 3 2 5 82371AB PCI to ISA B...

Страница 12: ...O Signals 3 29 3 5 1 J3 Signal Specification 3 29 3 5 1 1 Ethernet LEDs 3 29 3 5 1 2 Ethernet 1 3 29 3 5 1 3 Serial Port 3 3 30 3 5 1 4 Serial Port 4 3 30 3 5 1 5 IDE LED Signals 3 30 3 5 1 6 IR Seria...

Страница 13: ...1 4 1 BIOS Setup Program 4 1 4 1 1 Accessing the BIOS Setup Program 4 1 4 1 2 Main Menu 4 3 4 1 3 Setups 4 4 4 1 4 Standard CMOS Setups 4 5 4 1 5 Saving Exiting Operations 4 5 4 1 6 BIOS Features Set...

Страница 14: ...Devices Surface Mount D 1 D 2 Assembly Bottom Diagram D 2 D 3 Mounting Holes D 3 D 4 Connector Holes D 4 E CONNECTOR PINOUTS E 1 E 1 cPCI MXS64 Connectors and Headers E 1 E 2 J1 CPCI Bus E 2 E 3 J2 CP...

Страница 15: ...tch E 12 E 16 S1 Reset Switch E 12 E 17 BT1 CMOS Battery Backup Connector E 12 F BIOS SETUP ERROR CODES F 1 F 1 POST Beep F 1 F 2 POST Messages F 1 F 3 Error Messages F 2 F 4 POST Codes F 3 G EMERGENC...

Страница 16: ...1 PRODUCT DESCRIPTION 1 PRODUCT OVERVIEW 2 PRODUCT SPECIFICATIONS 3 HOT SWAP CAPABILITY 4 INTERFACING WITH THE ENVIRONMENT 5 COMPATIBILITY WITH KONTRON PRODUCTS 6 MEZZANINE CARD CONCEPTS PART...

Страница 17: ...sparent bridge the feature set of the cPCI MXS64 includes a rich selection of standard peripherals The cPCI MXS64 offers a natural growth path to high performance high availability as well as hot swap...

Страница 18: ...t Four serial ports three RS 232 only Serial Port 1 2 and 4 one RS 232 422 485 Serial Port 3 One Parallel port bi directional with all IEEE 1284 protocols supported with BIOS selectable IRQs and addre...

Страница 19: ...and Green support Hardware monitor voltages temperature and fan speed Power failure circuit Two year warranty The cPCI MXS64 can be purchased either for front plate I O interfacing video serial port...

Страница 20: ...le through the use of different pin lengths and the process ends with the mating of the shortest pin BD_SEL The platform adds hardware to provide more control of each board s Hardware Connection Layer...

Страница 21: ...board This LED indicates that system software has been placed in a state for orderly extraction of the board The hardware connection layer provides protection only for the hardware during insertions a...

Страница 22: ...3 J5 B In Rear I O configuration all I O signals are connected to J3 J5 A backplane dedicated to the cPCI MXS64 is provided by Kontron and is referred to as cBP08R cPCI Passive Backplane 1 4 2 Mezzani...

Страница 23: ...ne card with hard disk and floppy disk drive cMCB Mezzanine card with bridge hard disk and floppy disk cSM DVDHD Storage module with DVD and Hard Disk cSM DVD Storage module with DVD only CxP0816 incl...

Страница 24: ...chnical Reference Manual 1 8 1 6 MEZZANINE CARD CONCEPT The capability of the cPCI MXS64 to connect with other devices is enforced by PCI Mezzanine Cards PMC A fully equipped cPCI MXS64 board may appe...

Страница 25: ...evices The cPCI MXS64 features the PMC concept onboard to provide an extra method to support the 32 bit I O devices available on the market PMC devices connect directly to standard PMC connectors A me...

Страница 26: ...E 2 ENHANCED IDE INTERFACES 3 ETHERNET INTERFACES 4 FLOPPY DISK INTERFACE 5 PS 2 KEYBOARD AND MOUSE INTERFACE 6 PARALLEL PORT 7 POWER MANAGEMENT 8 SCSI INTERFACE 9 SERIAL PORTS 10 THERMAL MANAGEMENT 1...

Страница 27: ...lash Disk connector Related Jumpers cPCI MXS64 W3 to set the CompactFlash disk as master or slave BIOS Settings Section 4 1 2 Main Menu Hard Disk autodetect to set the type of hard disk 2 1 1 Setups T...

Страница 28: ...tor The secondary IDE interface is only available through the cPCI I O connector Related Jumpers None BIOS Settings Section 4 1 11 Integrated Peripherals The IDE interfaces supports PIO mode 4 transfe...

Страница 29: ...ings Section 4 1 11 Integrated Peripherals Enable Disable Ethernet Controller 2 3 1 Front Plate Configuration Ethernet 1 and 2 signals are available on front plate connectors only when the board is or...

Страница 30: ...through the Mezzanine connector see Section 1 4 1 Related Jumpers None BIOS Settings Section 4 1 4 Standard CMOS Select type of floppy Section 4 1 11 Integrated Peripherals Enable Disable onboard FDC...

Страница 31: ...egrated Peripherals Onboard Parallel Port Parallel Port Mode The differences between Standard EPP and ECP modes appear in the signal assignation of the pins on the connector Differences are described...

Страница 32: ...allel port can be used to connect more than one peripheral device using multiplexor or daisy chain configurations A multiplexor is an external device that permits up to eight parallel port devices to...

Страница 33: ...The boards feature SYM53C895 PCI to Ultra2 SCSI I O Processor Supports Ultra2 SCSI synchronous transfer rates up to 80 Mbytes s on a 16 bit LVD SCSI bus Signals are available through J3 J4 cPCI I O co...

Страница 34: ...peration Signals include the complete signal set for handshaking modem control interrupt generation and data transfer When assigned as Serial Port 1 the port is 100 compatible with the IBM AT serial p...

Страница 35: ...is entirely detected by hardware For truly remote operation use the VT 100 mode which allows remote BIOS setup and console redirection 2 9 1 2 Front Plate Configuration The Serial Port 1 signals are a...

Страница 36: ...speed over longer distances or improved reliability over similar RS 232 setups Signal Path In RS 232 RS 422 and RS 485 operation modes Serial Port 3 signals are only available through the J5 cPCI I O...

Страница 37: ...hms termination resistors See Section 3 1 Jumper Settings 2 9 3 4 RS 485 Protocol The RS 485 protocol Half Duplex also uses differential signals during a communication session It differs from the RS 4...

Страница 38: ...d Jumpers None BIOS Settings 11 3 7 Integrated Peripherals Onboard Serial Port 4 IRQ Line for Serial Port 4 2 10 THERMAL MANAGEMENT Two temperature sensors are provided to supervise the thermal enviro...

Страница 39: ...nagement Options 2 11 USB INTERFACES Signals for two USB ports are available through the cPCI I O connector J5 The USB strengths are as follows capability to daisy chain as many as 127 devices per int...

Страница 40: ...4 1 9 PnP PCI Configuration Init Display First Assign IRQ for VGA Front Plate Configuration VGA interface signals are available on J12 standard VGA connector located on the front plate of the board o...

Страница 41: ...nsions to VGA including resolutions up to 800x600x16 8 million colors non interlaced The 16 bit images are displayed at up to 1024x768 resolution 2D Graphics Engine The 2D graphics engine is an advanc...

Страница 42: ...3 INSTALLING THE BOARD 1 SETTING JUMPERS 2 REGISTER S DESCRIPTION 3 ONBOARD INTERCONNECTIVITY 4 CUSTOMIZING THE BOARD 5 BUILDING A cPCI SYSTEM 6 cPCI I O SIGNALS PART...

Страница 43: ...iguration W3 Onboard Battery Connects or Disconnects the battery to from the board circuitry W4 Remote Reset To select Serial Port 1 or Serial Port 2 as a source for the remote hardware reset W5 SCSI...

Страница 44: ...ut W3 Compact Flash Disk W4 Battery RS 422 485 modes only With termination Without termination W8 W9 COM2 Terminations DS1 1 1 4HP Configuration 8HP Configuration in out Connected Disconnected Enable...

Страница 45: ...n The serial port 2 mode can be controlled by setting three bits Here are the possibilities Mode Bit RS485 Bit RS232 Bit ST1 RS232 0 1 X RS422 1 0 0 RS485 1 0 1 X Don t care 3 1 4 History and Monitor...

Страница 46: ...cess CPLD Address D7 D6 D5 D4 D3 D2 D1 D0 READ n93h NU NU NU NU IDCHIP NU I2C_CLK I2C_DATA WRITE n93 h NU NU NU NU IDCHIP NU I2C_CLK I2C_DATA Power up Default 0 0 0 I2C_DATA I2C data I2C_CLK I2C Clock...

Страница 47: ...D Address D7 D6 D5 D4 D3 D2 D1 D0 READ n95 CND4 CIS4_1 CIS4_0 CBAS4_ 1 CBAS4_0 WRITE n95 CND4 CIS4_1 CIS4_0 CBAS4_ 1 CBAS4_0 NU Power up Default 0 0 0 1 1 CND4 When low decode the base address CIS4_ 1...

Страница 48: ...65536T NMI T 8T 111 262144T NMI T 8T Time out selection with T 1 08ms TBC 3 1 10 NMI Control CPLD Address D7 D6 D5 D4 D3 D2 D1 D0 READ n97 BATFEN BATFLT NU NU NU NU WDNMIEN WDNMI WRITE n97 BATFEN NU N...

Страница 49: ...IS3_1 CIS3_0 CBAS3_1 CBAS3_0 RESERVED READ RESERV n95 WRITE _CND4 CIS4_1 CIS4_0 CBAS4_1 CBAS4_0 NU NU READ n96 WRITE WDEN WDD2 WDD1 WDD0 NU READ BATFLT WDNMI n97 WRITE BATFEN NU NU WDNMIEN NU READ n98...

Страница 50: ...2 Stage Watchdog 5V SMBus Hot Swap Controller Early Power CompactPCI J3 J4 Connectors Arbiter SYM53C895 LVD SCSI Term System Clock Intel Pentium III GTL XTAL XTAL EEPROM EEPROM 82559 100Base T Etherne...

Страница 51: ...CI bus 3 2 2 Mobile Pentium II III Processor The cPCI MXS64 system board supports the Intel s Low Power 500 700MHz Pentium III processor Higher clock speeds will be available when Intel will release t...

Страница 52: ...capability In addition it supports buffering of simultaneous multiple posted writes and delayed transactions in both directions The PCI to PCI bridge allows the Primary and Secondary PCI buses to ope...

Страница 53: ...ctor VGA J12 Supports standard 15 pin DSUB female connector Serial Port 1 J13 Supports standard 9 pin DSUB male connector Kontron s Mezzanine J14 J19 This connector handles PCI bus signals to the mezz...

Страница 54: ...ity on IDE SCSI devices Indicate a board failure ready to swap J13 Com Port 1 Standard 9 pin DSUB male connector J16 J15 Ethernet 1 and 2 RJ 45 connectors with built in activity and link indicators J1...

Страница 55: ...Installing the Board 3 13 3 2 8 Faceplate Options 1 5 6 9 1 15 1 5 6 9 4HP Front Access 4HP Rear Access 8HP Front Access 8HP Rear Access 8HP Front Access with Floppy 8HP Rear Access with Floppy...

Страница 56: ...sk reset USB SMBus and power signals cPCI J4 Connector Supports Ethernet1 secondary IDE channel SCSI VGA and power signals cPCI J3 Connector Supports serial ports 3 and 4 V Port Ethernet1 and power si...

Страница 57: ...nents particular attention should be given while installing a processor on the board Improper installation may damage the board and or the CPU CAUTION Since CPUs are very sensitive components particul...

Страница 58: ...ackup BIOS setup values and the real time lock RTC When replacing the battery must be connected as follows WARNING Danger of explosion if battery is incorrectly replaced Replace only with the same or...

Страница 59: ...modules single sided or double sided Unbuffered 100MHz SDRAM Serial Presence Detect SPD EEPROM Errors Checking and Correction ECC capabilities or parity bit with 72 bit modules Compliant with Intel s...

Страница 60: ...t plate is facing you 2 Hold the module vertically so that the bottom connector key is at right Install the DIMM straight down into the DIMM socket The socket s keys will ensure a correct mating 3 Pre...

Страница 61: ...oard battery When the battery is in a low condition below 2 9V typical the PFO power fail output signal goes low The status of the PFO signal can be read at I O address 4031h bit 1 0 failed 1 good An...

Страница 62: ...aring the lock bit in register 0x92h bit 2 then set th4e bit WDEN bit 7 in register n92h and relock it by setting the lock bit in register 0x92 bit 2 The following is an example in C language define T...

Страница 63: ...rom reaching count 0 timeout The following C language procedure can be used to trigger the programmable watchdog define TekReg 0x190 define base address 0x190 0x290 or 0x390 void TrigWatchdog timeout...

Страница 64: ...s 1ms 001 0 065s 0 065s 1ms 010 0 261s 0 261s 1ms 011 1 044s 1 044s 1ms 100 4 174s 4 174s 1ms 101 16 69s 16 69s 1ms 110 66 79s 66 79s 1ms 111 267 1s 267 1s 1ms A reset from the programmable watchdog i...

Страница 65: ...ent consists in a chassis a CompactPCI backplane a storage module a power supply unit and a ventilation system The main AC power is drawn to the chassis components through an IEC power plug with a 2 s...

Страница 66: ...is driven directly by the system processor while the other is managed through a PCI to PCI bridge implemented on the cMCB 2RC mezzanine card Storage PCI to PCI mezzanine All Kontron s CompactPCI backp...

Страница 67: ...ocessor to the rear of the enclosure using a Rear I O Transition module cTM80 STD2S The Rear I O Transition module gathers all the I O signals of the CPU board and makes them easily accessible through...

Страница 68: ...cPCI MXS64 Technical Reference Manual 3 26 The cTM80 STD Transition Module 8HP configuration 1 Rev...

Страница 69: ...ed 3 4 5 Fan Tray The ventilation unit of the enclosure conforms to the global requirement of the system in fully loaded configuration 3 4 6 Installing the Board into a Bay The cPCI MXS64 is mechanica...

Страница 70: ...48V Red 3 4 8 Bus Mastering The cPCI MXS64 provides seven pairs of REQ GNT 0 6 arbitration signals through the Secondary PCI bus This means the board is capable of driving up to seven cPCI slots with...

Страница 71: ...on the handle and gently remove the board 3 5 cPCI I O SIGNALS This section describes integrated feature signals available on rear panel cPCI I O connectors J3 J4 and J5 3 5 1 J3 Signal Specification...

Страница 72: ...Signal Pin Assignation Description COM4 DCD A11 Data Carrier Detect COM4 RXD C11 Receive Data COM4 DSR D11 Data Set Ready COM4 TXD E11 Transmit Data COM4 RTS A12 Ready To Send COM4 CTS B12 Clear To Se...

Страница 73: ...icate the CompactPCI Bus reset signal 3 5 1 8 Miscellaneous Signals Signal Pin Assignation Description PWRBT A19 ACPI Reserved EXT SMI B19 System Management Interrupt Input PX4 NMI C19 Non Maskable In...

Страница 74: ...se it is received SMSG E3 SCSI Message Indicates a Message phase when asserted and Command or Data phase when not asserted RST A4 Reset Signal is interpreted as a hard reset and will clear all command...

Страница 75: ...rectly driven from the IDE device DMARQ signal It is asserted by the IDE device to request a data transfer IDE1 IOW C21 Sec Disk I O Write In normal IDE mode this is the command to the IDE device that...

Страница 76: ...SDD lines PIORDY B5 Prim I O Channel Ready In normal mode this input signal is driven directly by the corresponding IDE device IORDY signal IDE0 DACK D5 Prim DMA Acknowledge This signal directly drive...

Страница 77: ...ad select FD DSKCHG E10 Disk change 3 5 3 4 Serial Port 2 Signal Pin Assignation Description COM2 DCD A11 Data Carrier Detect COM2 RXD C11 Receive Data COM2 DSR D11 Data Set Ready COM2 TXD E11 Transmi...

Страница 78: ...17 Error at printer STB A19 Strobe signal 3 5 3 7 Miscellaneous Signals Signal Pin Assignation Description SMBDATA B20 Onboard SMbus data SMBALERT C20 Onboard SMbus Alert CPU overheating SMBCLK E20 On...

Страница 79: ...4 SOFTWARE SETUPS 1 BIOS SETUP PROGRAM 2 VT100 MODE NOTE UPDATING OR RESTORING THE BIOS IN FLASH see the Kontron FTP site and select the support section 4 PART...

Страница 80: ...rom LAN utility this utility is located on the driver s CDROM 4 1 1 Accessing the BIOS Setup Program The system BIOS Basic Input Output System provides an interface between the operating system and th...

Страница 81: ...of default values The list of defaults is provided in the event that a value has been changed and one wishes to set this option to its original value Loading the BIOS or SETUP defaults will affect al...

Страница 82: ...rated peripherals controller in your system Load Bios Defaults The BIOS defaults are fail safe settings that consist of the safest set of parameters Use them if the system is behaving erratically They...

Страница 83: ...n you entered the program When in BIOS Features Setup Chipset Features Setup Power Management Setup PNP PCI Setup or Integrated Peripherals Setup Restores the previous setup values for that setup scre...

Страница 84: ...e basic type of display adapter card installed in the system Halt on This option specifies the type of errors that will stop the system during the BIOS booting procedure A message asks that you press...

Страница 85: ...eing displayed contact the Technical Support see appendix G Boot from LAN First Dis Dis En Dis If Enabled the BIOS will first attempt to boot from the LAN The complete procedure for this function is a...

Страница 86: ...te Access For All All All Supervisor When this option is set to Supervisor and the Security option to System all floppy disk accesses read write are limited to the Supervisor supervisor password requi...

Страница 87: ...e SDRAMs and when the chipset samples read data from the SDRAMs Select 3 for 3 DCLKs and 2 for 2 DCLKs If a given row is populated with a registered SDRAM DIMM an extra clock is inserted between the r...

Страница 88: ...AT ATX This option selects the type of power supply AGP Aperture Size MB 64 64 4 to 256 This option selects the size in megabytes of the AGP Aperture Video BIOS Shadow En En En Dis C8000 CBFFF En En...

Страница 89: ...eo buffer Video Off After Standby Standby NA Suspend Standby Doze As the system moves from lesser to greater power saving modes select the mode in which you want the monitor to blank Doze Mode Dis Dis...

Страница 90: ...arm Dis Dis En Dis When Enabled allows setup of a time to re activate the CPU when in Suspend mode with the options Date of Month Alarm and Time hh mm ss Alarm Note The IRQ 8 Break Suspend option in t...

Страница 91: ...pt PCI ISA PnP Devices compliant with the Plug and Play standard whether designed for PCI or ISA bus architecture When Legacy ISA is selected for an IRQ line this resource will not be available for PC...

Страница 92: ...Overheat Alarm C temperature Full speed Normal mode will be resumed when the temperature comes down to the selected Resume Alarm C temperature A minimum of 4 is automatically ensured for the Overheat...

Страница 93: ...nboard SCSI controller Ethernet Controller 1 and 2 En En En Dis Enables disables the onboard Ethernet controller USB Keyboard Support OS OS OS BIOS This option is for DOS and BIOS support only Win 95...

Страница 94: ...ction verifications At power up there is floppy disk led activity which is one sign that the BIOS as detected a corrupted BIOS CRC prior POST and falled back automatically to Emergency Recovery Mode l...

Страница 95: ...power 2 Enter into the CMOS Setup program in the BIOS Feature Setup 3 Select the VT100 mode and the appropriate COM port and save your setup 4 Connect the communications cable as shown in the next pag...

Страница 96: ...l attached If the speed is set to Auto and no terminal is connected the speed is set to 115 200 bauds Furthermore you can run without any console at all by simply not enabling VT100 Mode and by disabl...

Страница 97: ...APPENDICES A BOARD SPECIFICATIONS B MEMORY I O MAPS C INTERRUPT LINES D BOARD DIAGRAMS E CONNECTOR PINOUTS F BIOS SETUP ERROR CODES G EMERGENCY PROCEDURE H GETTING HELP RMA PART...

Страница 98: ...cPCI MXS64 Level 1 16 16KB instruction Data CPU internal Level 1 Level 2 256KB internal 64 bit wide pipelined burst System Memory Three 168 pin Latching DIMM sockets 64 72 bit Up to 768Mb of SDRAM wit...

Страница 99: ...MC FDC37C672 USB Ports Two Serial Ports Four three RS 232 COM1 2 4 Com3 configurable as RS 422 485 Parallel Port One bi directional with all IEEE 1284 protocols supported with BIOS selectable IRQs and...

Страница 100: ...ftware enable disable of onboard Ethernet SCSI hardware enable disable of onboard video Diskless keyboardless and videoless operation extensions System video SCSI LAN and extension BIOS shadowing Prog...

Страница 101: ...densing Altitude 4 572m 15 000 ft 15 240m 50 000ft Shock Designed to meet IEC 68 2 27 Vibration Designed to meet IEC 68 2 6 Reliability MTBF cPCI MXS64 54810 hours 20 C MIL HDBK 217F Board serial numb...

Страница 102: ...o device address may vary E0000 FFFFF System BIOS 100000 Top of DRAM 1 MB Top of DRAM 1MB to top of DRAM System BIOS See detailed map to the right 0 640KB DRAM Optional ROM Free SCSI BIOS 18KB at runt...

Страница 103: ...terrupt Controller 2 0C0 0DF DMA Controller 2 0F0 0F1 0F8 0FF Math Coprocessor 190 197 290 297 390 397 Kontron Control Port 1F0 1F7 3F6 Primary IDE 170 177 376 Secondary IDE 3F0 3F7 370 377 Floppy Dis...

Страница 104: ...E or available 1 All functions marked with an asterisk can be disabled or reconfigured 1 Available lines service on board and external PCI ISA PnP devices or a Legacy ISA device C 2 DMA CHANNELS The c...

Страница 105: ...D 1 D BOARD DIAGRAMS D 1 TOP DEVICES SURFACE MOUNT...

Страница 106: ...cPCI MXS64 Technical Reference Manual D 2 D 2 ASSEMBLY BOTTOM DIAGRAM...

Страница 107: ...Board Diagrams D 3 D 3 MOUNTING HOLES...

Страница 108: ...CTOR HOLES 8 971 8 734 8 459 7 759 6 494 4 636 4 084 3 892 3 659 3 374 0 000 0 216 0 140 0 000 0 103 0 180 0 510 2 935 4 630 5 025 5 420 6 100 6 159 0 000 0 059 1 909 3 309 3 669 5 191 7 159 0 000 0 1...

Страница 109: ...nt panel configuration only J13 Serial Port 1 RS 232 Front panel configuration only J14 Mezzanine PCI Connector J15 Ethernet 1 Connector Front panel configuration only J16 Ethernet 2 Connector Front p...

Страница 110: ...I O AD25 AD24 9 CBE3 RSB AD23 GND AD22 10 AD21 GND VCC3E AD20 AD19 11 AD18 AD17 AD16 GND CBE2 12 13 14 KEY AREA 15 VCC3E FRAME IRDY BD_SEL TRDY 16 DEVSEL GND V I O STOP LOCK 17 VCC3E I2C_SCL I2C_SDA G...

Страница 111: ...60 7 AD59 GND V I O AD58 AD57 8 AD56 AD55 AD54 GND AD53 9 AD52 GND V I O AD51 AD50 10 AD49 AD48 AD47 GND AD46 11 AD45 GND V I O AD44 AD43 12 AD42 AD41 AD40 GND AD39 13 AD38 GND V I O AD37 AD36 14 AD35...

Страница 112: ...1 SPLED 7 LAN1 ACTLED SD7 SD6 SD5 SD4 8 GND VCC VCC SD3 SD2 9 LAN1 ETX LAN1 ETX LAN1 ERX LAN1 ERX GND 10 GND WR_80 SD1 12V 12V 11 COM4 DCD GND COM4 RXD COM4 DSR COM4 TXD 12 COM4 RTS COM4 CTS COM4 RI V...

Страница 113: ...I MSG S5HEALTHY VGA SDATA S5PCIRST 10 VGA SCLK VGA HSYNC VGA VSYNC VGA RED VGA GREEN 11 VGA BLUE SCSI D3 S6BDSEL SCSI D5 SCSI D6 12 13 14 KEY AREA 15 SCSI D0 VCC VCC S6HEALTHY S6PCIRST 16 LAN0 ETX LAN...

Страница 114: ...DATA FD HDSEL FD DSKCHG 11 COM2 DCD GND COM2 RXD COM2 DSR COM2 TXD 12 COM2 RTS COM2 CTS COM2 R VCC COM2 DTR 13 COM1 DCD VCC COM1 RXD COM1 DSR COM1 TXD 14 COM1 RTS COM1 CTS COM1 R GND COM1 DTR 15 LPT S...

Страница 115: ...S3_PCI_RST GND 12V 12V PBRST AD2 GND AD7 AD9 VCC AD13 C BE1 GND PERR VCC3 TRDY GND AD16 VCC3 AD20 AD23 GND C BE3 AD26 VCC AD30 GND MS8_PCI_RST VCC PCLK_MEZ VCC INTA INTB ENUM MS4_BD_SEL AD1 AD4 GND AD...

Страница 116: ...3 4 5 6 E 11 J18 COMPACTFLASH DISK Pin Number Top View Pin Number Signal Signal D11 D12 D13 D14 D15 CS1 DMACK DMARQ PDIAG IRQ15 VCC GND RESET CSEL A1 A0 D0 D1 D2 IOCS16 1 3 5 7 9 11 13 15 17 19 21 23...

Страница 117: ...DEX FD DSKCHG FD MTR0 FD STEP FD GATE FD WRTPTR FD HSEL VCC VCC MOUSE DATA KB CLK GND GND GND GND GND FD DRVEN0 FD MTR1 FD DS0 FD ET FD DIR FD WDATA FD TRK0 FD RDATA 12V VCC VCC D1 D3 D5 D7 D9 D11 D13...

Страница 118: ...GND DEVSEL GND SDONE PAR VCC AD12 AD9 GND AD6 AD4 VCC AD2 AD0 GND 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 3...

Страница 119: ...VCC3 C BE1 AD14 GND AD8 AD7 VCC3 N C N C GND N C GND 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40...

Страница 120: ...Reference Manual E 12 E 15 HOT SWAP SWITCH Signal Top View VCC3E SW_OPEN GND 1 2 3 E 16 S1 RESET SWITCH Signal View RESET GND 1 2 E 17 BT1 CMOS BATTERY BACKUP CONNECTOR Signal Front View Battery Batte...

Страница 121: ...IOS checksum error 22 Error when getting the boot block flash ID code 33 Error when erasing the boot block flash 44 Error when programming the boot block flash 55 Success of the boot block recovery co...

Страница 122: ...ive does not contain proper system boot files Insert a system disk into Floppy Drive A and press Enter If you assumed the system would boot from the hard drive make sure the controller is inserted cor...

Страница 123: ...lt show POST BEh 09 Early Cache Initialization 1 Check for Intel s and or Cyrix CPU 2 Early Cache Initialization when cache is separate from chipset 3 Turn off Gate A20 0A Setup Interrupt Vector Table...

Страница 124: ...ation 14h to find out type of video to use Detect and initialize Video Adapter 12 Init T380 if necessary Boot Block in EMERGENCY Try to init Video Card 0E Test Video Memory 1 If CGA or MONO test video...

Страница 125: ...st test is performed 32 Test EISA Extended Memory If EISA Mode flag is set then test EISA memory found in slots Initialization NOTE 1 This will be skipped in ISA mode NOTE 2 This POST also Detect Repo...

Страница 126: ...BIOS area 54 5F Reserved Reserved 60 Store boot partition of head cylinder 61 Final Init For last s detail before boot 62 Num Lock ON Put Num Lock ON and Daylight Saving 63 Boot Attempt 1 Call POST 82...

Страница 127: ...ific Routine for programming which region are cacheable Boot Block Cache Sizing C7 Reserved Reserved C8 Special Speed Switching OEM Specific Routine to handle speed switching C9 Special Shadow Handlin...

Страница 128: ...PROCEDURE To run an EMERGENCY PROCEDURE proceed as follows 1 Remove battery jumper 2 Disable the Power Fail Detection function 3 Connected a 1 44MB floppy drive drive A to the board and insert the EM...

Страница 129: ...then press Enter key 5 The program may display one of the following messages Emergency Code transferred The emergency diskette has been successfully created Take the appropriate actions and restart f...

Страница 130: ...about Kontron our products or services you may reach us at the above numbers or by writing to Kontron Inc 616 Cur Boivin Boisbriand Qu bec J7G 2A7 Canada LIMITED WARRANTY Kontron Inc The seller warra...

Страница 131: ...tain you receive an RMA number from Kontron s Technical Support and clearly mark this number on the outside of the package you are returning To request a number follow these steps Make a copy of the r...

Страница 132: ...437 8053 Contact Name ______________________________________________ Company Name _______________________________________________ Street Address _______________________________________________ City __...

Отзывы: