www.kontron.com
CP6940 User Guide
// 64
POST Fail (Type 0Fh)
Table 24: MMC FwUp (Type C7h) Event Message
Offset
Request data
1
Event Message Rev
04h
2
Sensor Type
C7h – OEM Firmware Upgrade
3
Sensor Number
4
[7] – Event Direction
1b = Deassertion
0b = Assertion
[6-0] – Event Type
6Fh = sensor specific
5
Event Data 1
[7:4] – 0h = no data in Event Data 2 and 3
[3:0] – Offset
00h = first boot after upgrade
01h = first boot after rollback
All other values are reserved.
6
Event Data 2
FFh = not specified
7
Event Data 3
FFh = not specified
Response data
1
Completion Code
SDR Configuration
Value
Description
Assertion Event Mask
01h
Offset 0 can generate an assertion event
Deassertion Event Mask
00h
Sensor cannot generate deassertion events
Table 25: POST Fail (Type 0Fh) Reading
Offset
Request data
1
Sensor Number
Response data
1
Completion Code
2
Sensor Reading
00h – ignore on read
3
Standard IPMI Byte. (See “Get Sensor Reading in the IPMI Specification)
4
[7:1] – reserved, ignore on read
[0] – 1b = System Firmware Error (POST Error)
5
80h – ignore on read