background image

www.kontron.com

CP6940 User Guide

// 49

Firmware versio0n (e.g. PLD) and write protect status

System and IPMI release

To use the MIBs, you must import the MIBs into the MIB browser. The MIBs are provided on demand for current releases.

SNMP can also be used for updating System Software, IPMI  FW and PLD.

4.3

Bootloader

On the CP6940 Ethernet Switch, the bootloader 'u-boot' (universal bootloader) is used. The bootloader initializ-es the
main components of the system like Unit Computer, DDR3 RAM, serial lines etc. for operation and per-forms a power on
self test (POST). After these steps have been finished, the bootloader loads and starts the linux OS stored on eMMC
device.

Two instances of the bootloader stored on the system. One resides on eMMC and is the one used for normal operation. In
case of failure or corruption of the normal operation bootloader, the failsafe bootloader that is stored on write protected
SPI flash will start instead. This redundancy concept allows for recovery actions in case of failure.

Содержание CP6940

Страница 1: ...www kontron com CP6940 Document Revision 0 9 Draft Version Date September 2019 User Guide...

Страница 2: ...ble for the specified use without further testing or modification Kontron expressly informs the user that this manual only contains a general description of processes and instructions which may not be...

Страница 3: ...o ensure that your systems and any Kontron hardware or software components incorporated in your systems meet all applicable requirements Unless otherwise stated in the product documentation the Kontro...

Страница 4: ...oblems as soon as possible and post the revi sed user guide on our website Terms and Conditions Kontron warrants products in accordance with defined regional warranty periods For more information abou...

Страница 5: ...rve the precautions indicated and or prescribed by the law may endanger your life health and or result in damage to your material Please refer also to the High Voltage Safety Instructions portion belo...

Страница 6: ...particularly important to observe standard anti static precautions when changing piggybacks ROM devices jumper settings etc If the product contains batteries for RTC or memory backup ensure that the p...

Страница 7: ...n re pack it in the same manner as it was delivered Special care is necessary when handling or unpacking the product See Special Handling and Unpacking Instruction Environmental Protection Statement T...

Страница 8: ...nics 14 1 2 3 Temperature 14 1 2 4 Humidity 14 1 2 5 Altitude 14 1 2 6 Vibration 14 1 2 7 Shock 15 1 2 8 Bump 15 1 2 9 Safety 15 1 2 10 Electromagnetic Compatibility 15 1 2 11 Reliability 15 1 2 12 WE...

Страница 9: ...Quality of Service 44 4 1 6 FASTPATH Multicast 45 4 2 Supported MIBs 45 4 2 1 Enterprise MIB 45 4 2 2 Base Package MIBs 45 4 2 3 Switching Package MIBs 46 4 2 4 Routing Package MIBs 47 4 2 5 QoS Packa...

Страница 10: ...Table 16 HPM 1 Commands 54 Table 17 Kontron OEM Commands 55 Table 18 Sensor List 59 Table 19 IPMB Link Type C3h Reading 61 Table 21 MMC Reboot Type 24h Reading 62 Table 20 IPMB Link Type C3h Event Mes...

Страница 11: ...tional Block Diagram 25 Figure 3 Front Panel of the CP6940 RA OC P 29 Figure 4 Front Panel of the CP6940 RA OC 29 Figure 5 Font Panel of the CP6940 SA OC V 29 Figure 6 LED description CP6940 RA OC P 3...

Страница 12: ...ront uplinks 2x QSFP for 40G or 4 times 10G 4x 10G SFP 2x 1G SFP Layer 2 3 management Ready for extended Temperature Range 40 to 85 C CP6940 SA OC V Value line optical copper managed layer 2 Switch wi...

Страница 13: ...oard Voltage and current monitoring Board Temperature monitoring via I C enabled sensors 1 1 1 4 Power Supply 5V and 3 3V only board no 12V or 12V required IPMB_PWR used for 3 3V PM generated by LDO H...

Страница 14: ...ntegrator Storage temperature range is 50 C to 105 C for all variants 1 2 4 Humidity The board is designed to meet the standard IEC 60068 2 78 operating 93 at 40 C non condensing 1 2 5 Altitude The bo...

Страница 15: ...B limit of the following specifications requirements assuming an ade quate system chassis FCC 47 CFR Part 15 Subpart B USA EN55032 Europe EN61000 VCCI Voluntary Japan Electromagnetic Compatibility re...

Страница 16: ...tiation of speeds and operational mode on all external copper GE interfaces as well as on all base fabric interfaces Layer 2 multicast services using GARP GMRP IEEE 802 1p VLAN support including VLAN...

Страница 17: ...r retrieving and installing multiple configurations Support for startup configurations based on the cPCI SGA GA Shelf Geo graphical Address Geographical Address see CP6940 CLI Reference Man ual chapte...

Страница 18: ...CP6940 The SFP cages have sharp edges which might lead to injuries ESD Sensitive Device The CP6940 board contains electrostatically sensitive devices Please observe the necessary precautions to avoid...

Страница 19: ...d to the system before proceeding Carefully insert the board into the slot designated by the application requirements for the board until it makes contact with the backplane connectors Using both ejec...

Страница 20: ...from the backplane by first unlocking the board ejection handles and then by pressing the han dles as required until the board is disengaged 6 After disengaging the board from the backplane pull the...

Страница 21: ...s are 115200 bps serial speed might be different for customized board variants 8 bit no parity 1 stop bit 8N1 no flow control 2 5 1 2 Gigabit Ethernet Serviceport The Gigabit Ethernet serviceport on t...

Страница 22: ...etwork port is described in the following User input is printed in bold letters 1 Connect to serial port on the front plate using the Kontron DB9 adapter cable or RIO module using a RJ45 straight cabl...

Страница 23: ...ia Gigabit Ethernet networkport open a telnet connection to the configured IP address port 23 It might make sense to separate the management network from the data path by setting appropriate VLANs For...

Страница 24: ...RS232 UART_R I2C S I2C M Power Hotswap 5 0 V 3 3 V 5 0 V IPMI JTAG IPMB 1 IPMB 0 HEALTHY BD_SEL GA 4 0 SA 4 0 1 0 V_SW TEMP SENSOR TMP423 FRU EEPROM AT24C512 SPI I2C KCS SPI S KCS SPI M ADC IMON 5V 3...

Страница 25: ...IPMB 1 IPMB 0 HEALTHY BD_SEL GA 4 0 SA 4 0 TEMP SENSOR TMP423 FRU EEPROM AT24C512 SPI I2C KCS SPI S KCS SPI M ADC CP6940 SA OC V Sec Boot Flash 25DF161 RESET TPS3808 GPIO GA 4 0 BRD_REV 2 0 Debug Con...

Страница 26: ...rnet Port Mapping CLI Interface Speed Settings CP6940 RA OC P CP6940 RA OC CP6940 SA OC 0 1 FL 1 FL 1 FL 1 10 100 1000 Mbps 0 2 FL 2 FL 2 FL 2 10 100 1000 Mbps 0 3 FL 3 FL 3 FL 3 10 100 1000 Mbps 0 4...

Страница 27: ...des several I C interfaces for access to sensors and IPMB busses Board voltage current and temperature monitoring are accomplished through internal and external sensors The following section provides...

Страница 28: ...tages can be measured by the Peripheral Manager internal A D converters V_5V_CPCI_CURRENT The measuring range is 5 6A V_3V3_CPCI_CURRENT The measuring range is 10 2A Table 3 CP6940 Voltages and Operat...

Страница 29: ...te are four SFP ports the four front RJ45 ports the front RS232 and the management port accessible Also are there the status LEDs for the 24 GBE ports the hot swap LED the LED1 and the LED2 visible To...

Страница 30: ...fied yet 3 4 1 6 LED1 Alarm red Off all sensor values are within their specified range On one or more sensor values are out of their specified range Blinking not specified yet 3 4 1 7 LED2 Status gree...

Страница 31: ...f 10Base T On amber 100Base Tx On Green 1000Base T 3 4 1 13 CPLD healthy LED The CPLD healthy LED indicates that all Voltages are in their specified range and the CPLD is out of reset On CPLD is out o...

Страница 32: ...4th 2000 The SFP connectors have the following pin assignment 1 MODDEF2 is used as SFP SDA signal MODDEF1 is used as SFP SCL signal MODDEF0 is used as SFP PRESENT signal PIN9 GND is used as RATE2_SELE...

Страница 33: ...MDI Contact MDI 30 1 BI_DA 31 1 BI_DA 32 1 BI_DA 33 1 BI_DA 30 2 BI_DA 31 2 BI_DA 32 2 BI_DA 33 2 BI_DA 30 3 BI_DB 31 3 BI_DB 32 3 BI_DB 33 3 BI_DB 30 4 BI_DC 31 4 BI_DC 32 4 BI_DC 33 4 BI_DC 30 5 BI...

Страница 34: ...aling voltages V I O of either 3 3 V or 5 V No keying is required on J1 which designates universal V I O The CP6940 is compatible with all standard 6U CompactPCI passive backplanes with rear I O suppo...

Страница 35: ...ND 20 NC GND V_IO_CPCI NC NC GND 19 V_3V3_CPCI NC NC GND NC GND 18 NC GND V_3V3_CPCI NC NC GND 17 V_3V3_CPCI IPMB0_SCL IPMB0_SDA GND NC GND 16 NC GND V_IO_CPCI NC NC GND 15 V_3V3_CPCI NC NC CPCI_BD_SE...

Страница 36: ...C NC NC NC GND 19 NC NC IPMB1_SDA IPMB1_SCL IPMB_ALERT GND 18 NC NC NC NC NC GND 17 NC NC NC NC NC GND 16 NC NC NC NC NC GND 15 NC NC NC NC NC GND 14 NC NC NC NC NC GND 13 NC NC NC NC NC GND 12 NC NC...

Страница 37: ...L_DC8 FL_DC8 GND 15 FL_DB8 FL_DB8 GND FL_DD8 FL_DD8 GND 14 FL_DA7 FL_DA7 GND FL_DC7 FL_DC7 GND 13 FL_DB7 FL_DB7 GND FL_DD7 FL_DD7 GND 12 FL_DA6 FL_DA6 GND FL_DC6 FL_DC6 GND 11 FL_DB6 FL_DB6 GND FL_DD6...

Страница 38: ...D 23 FL21_DA FL21_DA GND FL21_DC FL21_DC GND 22 FL21_DB FL21_DB GND FL21_DD FL21_DD GND 21 FL22_DA FL22_DA GND FL22_DC FL22_DC GND 20 FL22_DB FL22_DB GND FL22_DD FL22_DD GND 19 FL23_DA FL23_DA GND FL2...

Страница 39: ...L_DD18 GND 18 FL_DA17 FL_DA17 GND FL_DC17 FL_DC17 GND 17 FL_DB17 FL_DB17 GND FL_DD17 FL_DD17 GND 16 FL_DA16 FL_DA16 GND FL_DC16 FL_DC16 GND 15 FL_DB16 FL_DB16 GND FL_DD16 FL_DD16 GND 14 FL_DA15 FL_DA1...

Страница 40: ...orms with file upload extensions RFC 1901 Community based SNMP v2 RFC 1908 Coexistence between SNMP v1 and SNMP v2 RFC 2068 HTTP 1 1 protocol as updated by draft ietf http v11 spec rev 03 RFC 2271 SNM...

Страница 41: ...ures IEEE 802 1AB Link level discovery protocol IEEE 802 1D Spanning tree IEEE 802 1p Ethernet priority with user provisioning and mapping IEEE 802 1Q Virtual LANs w port based VLANs IEEE 802 1s Multi...

Страница 42: ...ernet Networks RFC 896 Congestion Control in IP TCP Networks RFC 951 BOOTP RFC 1034 DOMAIN NAMES CONCEPTS AND FACILITIES RFC 1035 DOMAIN NAMES IMPLEMENTATION AND SPECIFICATION RFC 1321 Message digest...

Страница 43: ...Hiding Transit Only networks in OSPF RFC 5880 Bidirectional Forwarding Detection BFD RFC 5881 Bidirectional Forwarding Detection BFD for IPv4 and IPv6 Single Hop 4 1 4 FASTPATH IPv6 Routing Core Feat...

Страница 44: ...ess TCP UDP source port TCP UDP destination port IP protocol number IPv6 flow label Permit deny actions for inbound or outbound layer 2 traffic classification based on Source MAC address Destination M...

Страница 45: ...dards based MIBs 4 2 2 Base Package MIBs RFC 2273 SNMP Notification MIB SNMP Target MIB RFC 2572 SNMP Message Processing and Dispatching MIB RFC 2574 User based Security Model for SNMPv3 MIB RFC 2575...

Страница 46: ...s of managed objects for the Ethernet like interface types RFC 2011 SNMPv2 Management Information Base RFC 2213 Integrated Services MIB RFC 2233 The Interfaces Group MIB using SMI v2 RFC 2674 VLAN and...

Страница 47: ...lticast package MIBs RFC 2932 IPv4 multicast routing MIB RFC 5060 PIM SM and PIM DM MIB for IPv4 and IPv6 RFC 5240 BSR Protocol MIB Draft ietf idmr dvmrp mib 11 txt DVMRP MIB Draft ietf magma mgmd mib...

Страница 48: ...y CPU load Suppress MAC learning Fast Reload Memory Usage L2 port bridge Port blocking mode BPDU forwarding Suppress MAC learning kex_oem Customer specific information OEM serial number OEM hardware p...

Страница 49: ...tloader initializ es the main components of the system like Unit Computer DDR3 RAM serial lines etc for operation and per forms a power on self test POST After these steps have been finished the bootl...

Страница 50: ...tests Test Description Serial Onboard Unit Computer serial controller loopback test I2C Check for presence of onboard I2C devices PCI Express Check for PCI Express switch device presence Serviceport O...

Страница 51: ...e Var Serial line baudrate default 115200 bootargs Var Default kernel arguments quiet postresult 0x postresult vram_kinfo bootcmd Script This variable defines a command string that is automatically ex...

Страница 52: ...d and stored using the env set and env save bootloader CLI com mands Bootloader environment changes are stored in SPI flash sector Meddling with the bootloader environment variables can affect signifi...

Страница 53: ...o ensure continuity of operation of the board s management subsystem The MMC watchdog supervisor does not reset the payload power and the restart of the MMC will not affect the payload The external wa...

Страница 54: ...ommands M Get FRU Inventory Area Info 34 1 Storage 10h M Yes Read FRU Data 34 2 Storage 11h M Yes Write FRU Data 34 3 Storage 12h M Yes SEL Device Commands M Get SEL Info 31 2 Storage 40h O Yes Get SE...

Страница 55: ...Time 3Eh 3 03h OemApFormatStorage 3Eh 3 09h OemApSetSdrLocatorString 3Eh 3 0Ah OemApSetSerialNumber 3Eh 3 0Bh OemApGetSerialNumber 3Eh 3 0Ch OemApSetManufacturingDate 3Eh 3 0Dh OemApGetManufacturingDa...

Страница 56: ...re Revision BCD encoded depends on OEM soft ware minor release number 6 IPMI Version 51h IPMI version 1 5 7 Additional Device Support 7 1b device does implement chassis device support 6 0b device does...

Страница 57: ...causes the MMC to reset OemApSetNvData OemApGetNvData Command These commands provide raw access to the internally held parameter database that is stored inside the I2C EEPROM attached to the IPMI con...

Страница 58: ...s etc that specify the sensor s behavior Some fields of the sensor SDR are configurable through IPMI v1 5 command and are set to a built in initial value Module sensors that have been implemented are...

Страница 59: ...0 Sxx V_3V3 01h Voltage Payload Voltage 12 11 Sxx V_3V3_SUS 01h Voltage Suspend Voltage 13 12 Sxx V_3V3_CPLD 01h Voltage Suspend CPLD Voltage 14 13 Sxx V_3V3_CPCI 01h Voltage CPCI Voltage 15 14 Sxx V_...

Страница 60: ...0 85 000 95 000 6 S02 V_1V0 1 028 Volts ok na na na 75 000 85 000 95 000 7 S02 V_1V2 1 198 Volts ok na na 75 000 85 000 95 000 8 S02 V_1V25 1 277 Volts ok na na na na na na 9 S02 V_1V8 1 880 Volts ok...

Страница 61: ...rol state MMC determines state of the bus 2 0 IPMB L Local State 0h no failure bus enabled 1h unable to drive clock high 2h unable to drive data high 3h unable to drive clock low 4h unable to drive da...

Страница 62: ...ro 7 Event Data 3 7 4 Reserved read as zero 3 IPMB L Override State 0b override state bus isolated 1b local control state MMC determines state of the bus 2 0 IPMB L Local Status 0h no failure bus enab...

Страница 63: ...eserved 6 Event Data 2 FFh not specified 7 Event Data 3 FFh not specified Response data 1 Completion Code SDR Configuration Value Description Assertion Event Mask 02h Offset 1 can generate an assertio...

Страница 64: ...k All other values are reserved 6 Event Data 2 FFh not specified 7 Event Data 3 FFh not specified Response data 1 Completion Code SDR Configuration Value Description Assertion Event Mask 01h Offset 0...

Страница 65: ...stem Firmware Error POST Error All other values are reserved 6 Event Data 2 Post Code see 7 Event Data 3 unspecified Response data 1 Completion Code Table 27 Boot Fail Sensor Type 1Eh Reading Offset R...

Страница 66: ...Assertion 6 0 Event Type 6Fh sensor specific 5 Event Data 1 7 4 80h OEM data in Event Data 2 and no data in Event Data 3 3 0 Offset 00h local boot error while executing from flash 01h network boot err...

Страница 67: ...Sxx V_1V0 0 95V 0 98V 1 0V 1 02V 1 05V Sxx V_1V2 1 16V 1 176V 1 2V 1 224V 1 24V Sxx V_1V25 1 2V 1 225V 1 25V 1 275V 1 3V Sxx V_1V8 1 7V 1 764V 1 8V 1 872V 1 9V Sxx V_2V5 2 4V 2 45V 2 5V 2 55V 2 6V Sxx...

Страница 68: ...Supported are the following FRU data areas and data fields shown values are examples which may differ depending on the used board typ FRU Board Info Area Manufacturing date time Board manufacturer KO...

Страница 69: ...ate will be field save to be able to recover to a stable system in any case Information about update procedures will be provided later with a updated version of the document Table 32 On board SPI NOR...

Страница 70: ...oes not provide any active means of temperature regulation The Switch device and all PHYs have internal temperature diodes Their temperature values are stored in internal regis ters Additional there a...

Страница 71: ...Maximum Tem perature CP6940 SA OC V 24x 1Gbps traffic rear Front 4x 1GbBase T RJ45 2x 10 Gbe SFP 2x 1G SFP Forced Air 2m s 0 to 60 C CP6940 RA OC 24x 1Gbps traffic rear Front 4x 1GBase T RJ45 4x 10G S...

Страница 72: ...ese ratings Power consumption below 55 W 5 0 V VIN 5 3 designed for maximum load 5 50A 27 50W 3 3 V VIN 5 3 designed for maximum load 10 00A 33W 6 1 Backplanes Backplanes to be used with the CP6940 mu...

Страница 73: ...o of secure hardware middleware and services for Internet of Things IoT and Industry 4 0 applications With its standard products and tailor made solutions based on highly reliable state of the art emb...

Отзывы: