www.kontron.com
CP6940 User Guide
// 63
MMC FwUp (Type C7h)
Table 22: MMC Reboot (Type 24h) Event Message
Offset
Request data
1
Event Message Rev
04h
2
Sensor Type
24h – Platform Alert
3
Sensor Number
4
[7] – Event Direction
1b = Deassertion
0b = Assertion
[6-0] – Event Type
03h = digital discrete
5
Event Data 1
[7:4] – 0h = no data in Event Data 2 and 3
[3:0] – Offset
00h = MMC out of Reset
01h = MMC in Reset
All other values are reserved.
6
Event Data 2
FFh = not specified
7
Event Data 3
FFh = not specified
Response data
1
Completion Code
SDR Configuration
Value
Description
Assertion Event Mask
02h
Offset 1 can generate an assertion event
Deassertion Event Mask
00h
Sensor cannot generate deassertion events
Table 23: MMC FwUp (Type C7h) Reading
Offset
Request data
1
Sensor Number
Response data
1
Completion Code
2
Sensor Reading
00h = first boot after upgrade
01h = first boot after rollback
All other values are reserved.
3
Standard IPMI Byte. (See “Get Sensor Reading in the IPMI Specification)
4
00h - ignore on read
5
80h – ignore on read