COMe-bEP7 Module User Guide
www.kontron.com
// 46
7/
Environmental Specification
7.1.
Temperature Specification
Kontron defines following temperature grades for Computer-on-Modules in
general. Please see chapter 'Product Specification' for available temperature grades
for the COMe-bEP7.
Table 17: General Temperature Specification
Temperature
Specification
Operating
Non-operating
Commercial grade
0°C to +60°C
-30°C to +85°C
Industrial grade by
Design (E2)
-40°C to
+85°C
-40°C to +85°C
7.2.
Operating with Kontron heatspreader plate assembly
The operating temperature defines two requirements:
the maximum ambient temperature with ambient being the air surrounding the
module,
the maximum measurable temperature on any spot on the heatspreader's surface.
Table 18: Test Specification
Temperature Grade
Validation requirements
Commercial grade
at 60°C HSP temperature the CPU @ 100% load needs to
run at nominal frequency
Industrial grade by
Design (E2)
at 85°C HSP temperature the CPU @ 50% load is
allowed to start throttling for thermal protection
7.3.
Operating without Kontron heatspreader plate assembly
The operating temperature is the maximum measurable temperature on any spot
on the module's surface.
Humidity: Relative Humidity at 40°C is 93%, non-condensing (according to IEC 60068-2-78).
Содержание COMe-bEP7
Страница 1: ...USER GUIDE COMe bEP7 Module Doc Doc ID BEP7M102...
Страница 2: ...COMe bEP7 Module User Guide This page has been intentionally left blank...
Страница 27: ...COMe bEP7 Module User Guide www kontron com 27 Figure 2 Bottom View of COMe bEP7 5 2x COMe interfaces...
Страница 52: ...COMe bEP7 Module User Guide www kontron com 52 HOT Surface Do NOT touch Allow to cool before servicing...