Kontron COMe-bEP7 Скачать руководство пользователя страница 1

 

USER GUIDE

 

 

 

 

 

COMe-bEP7 Module 

Doc.       

Doc. ID: BEP7M102 

 

 

Содержание COMe-bEP7

Страница 1: ...USER GUIDE COMe bEP7 Module Doc Doc ID BEP7M102...

Страница 2: ...COMe bEP7 Module User Guide This page has been intentionally left blank...

Страница 3: ...ll be suitable for the specified use without further testing or modification Kontron expressly informs the user that this user guide only contains a general description of processes and instructions w...

Страница 4: ...uate design and operating safeguards You are solely responsible for compliance with all legal regulatory safety and security related requirements concerning your products You are responsible to ensure...

Страница 5: ...isit http www kontron com terms and conditions For contact information refer to the corporate offices contact information on the last page of this user guide or visit our website CONTACT US Customer S...

Страница 6: ...If you have any difficulties using this user guide discover an error or just want to provide some feedback contact Kontron support Detail any errors you find We will correct the errors or problems as...

Страница 7: ...essage Electric Shock This symbol and title warn of hazards due to electrical shocks 60 V when touching products or parts of them Failure to observe the precautions indicated and or prescribed by the...

Страница 8: ...your new Kontron product you are requested to conform with the following guidelines High Voltage Safety Instructions As a precaution and in case of danger the power connector must be easily accessibl...

Страница 9: ...urposes unless it is otherwise protected Whenever possible unpack or pack this product only at EOS ESD safe work stations Where a safe work station is not guaranteed it is important for the user to be...

Страница 10: ...mental requirements This also applies to the operational temperature range of the specific board version that must not be exceeded If batteries are present their temperature restrictions must be taken...

Страница 11: ...ctured to satisfy environmental protection requirements where possible Many of the components used are capable of being recycled Final disposal of this product after its service life must be accomplis...

Страница 12: ...nvironmental impact of their products especially when the product become waste Encourage separate collection and subsequent treatment reuse recovery recycling and sound environmental disposal of EEE I...

Страница 13: ...s 19 1 Introduction 20 1 1 Product Description 20 1 2 Product Naming Clarification 20 1 3 Understanding COM Express Functionality 22 1 4 COM Express Documentation 22 1 5 COM Express Benefits 22 2 Prod...

Страница 14: ...ation 46 7 2 Operating with Kontron heatspreader plate assembly 46 7 3 Operating without Kontron heatspreader plate assembly 46 7 4 Standards and Certifications 47 8 Mechanical Specification 50 8 1 Di...

Страница 15: ...tor Sub Menu 89 12 4 11 Serial Port Console Redirection Sub Menu 90 12 4 12 CPU Configuration Sub Menu 93 12 4 13 SIO Configuration Sub Menu 93 12 4 14 PCI Subsystem Settings Sub Menu 96 12 4 15 USB C...

Страница 16: ...COMe bEP7 Module User Guide www kontron com 16 13 Technical Support 112 13 1 Warranty 112 13 2 Returning Defective Merchandise 113 Appendix Terminology 114 About Kontron 118...

Страница 17: ...d SPI boot flash types for 8 SOIC package 54 Table 21 Time out Events 57 Table 22 3 pin Fan Connector 60 Table 23 Signal Description 60 Table 24 Designated I O Port Addresses 61 Table 25 I2C Bus Port...

Страница 18: ...Table 48 NVMe Configuration Sub Screens 99 Table 49 SATA Configuration Sub Screens 99 Table 50 Chipset Sub screens and Functions 100 Table 51 Security Setup Menu Functions 101 Table 52 Boot Setup Menu...

Страница 19: ...e bEP7R with D E3351 Processor 49 Figure 7 Module Dimensions 50 Figure 8 Module Height 51 Figure 9 Heatspreader Location and Dimensions 53 Figure 10 Entering USB Key Partition Name 55 Figure 11 3 pin...

Страница 20: ...sor System on Chip SoC Support Dual Die SP4 DDR4 memory technology up to 32 GByte ECC Modules 2x SODIMMs 4x SODIMMs optional 64 high speed lanes connectivity 32x PCIE 3 0 to COM Express Type 7 4x PCIE...

Страница 21: ...Guide www kontron com 21 AMD s processor code name EP EPYC Pinout type Type 7 Available temperature variants Commercial Industrial E2 Processor Identifier Chipset identifier if chipset assembled Memor...

Страница 22: ...3 0 4x USB 2 0 4x USB 3 0 4x USB 2 0 4x USB 3 0 4x USB 2 0 Serial Ports 2x 2x 2x LPC 1x 1x 1x External SPI 1x 1x 1x External SMB 1x 1x 1x External I2C 1x 1x 1x GPIO 8x 8x 8x 1 4 COM Express Documenta...

Страница 23: ...is flexibility differentiates products at various price and performance points and provides a built in upgrade path when designing future proof systems The modularity of a COM Express solution also en...

Страница 24: ...R4 non ECC ECC SO DIMM 68010 0000 51 4 COMe bEP7 E3451 COM Express basic pin out type 7 Computer on Module with AMD EPYC 3000 Processor E3351 16 core Quad 10GbE 1x GbE 2x DDR4 non ECC ECC SO DIMM 6801...

Страница 25: ...rade Modules by Design E2 40 C to 85 C Operating Product Number Product Name Description 68011 0000 55 2 COMe bEP7R E2 E3255 COM Express basic pin out type 7 Computer on Module with AMD EPYC 3000 Proc...

Страница 26: ...COMe bEP7 Module User Guide www kontron com 26 2 4 Product Views Figure 1 Top View of COMe bEP7 1 Processor 2 2x DDR4 memory 3 Onboard NVME 4 Fan Connector...

Страница 27: ...COMe bEP7 Module User Guide www kontron com 27 Figure 2 Bottom View of COMe bEP7 5 2x COMe interfaces...

Страница 28: ...on com 28 3 Functional Specification 3 1 Block Diagram COMe bEP7 Figure 3 displays the block diagram applicable to all COMe bEP7 modules Figure 3 Block Diagram COMe bEP7 basic pinout with AMD EPYC 300...

Страница 29: ...caches with DEC TED ECC DRAM DRAM ECC with Chipkill capabilities DRAM Address Command Parity with Replay DRAM Write Data CRC with Replay CRC protection of core CC6 state Parity on all internal data b...

Страница 30: ...80 85 100 35 45 30 55 30 55 Command 64Bit 64Bit 64Bit 64Bit 64Bit 64Bit 64Bit Cache MB 6 32 8 32 2 8 2 16 4 16 4 16 4 16 Memory Type DDR4 2666 DDR4 2666 DDR4 2666 DDR4 2666 DDR4 2666 DDR4 2666 DDR4 2...

Страница 31: ...kontron com 31 Table 5 Memory Features Socket 2x DDR4 SO DIMM default 4x DDR4 SO DIMM Optional with SP4 SKUs Memory Type Dual QUAD Channel DDR4 up to 2666 MT s up to 32 GB per socket Memory Module Siz...

Страница 32: ...15 can be bifurcated in x8 x4 x2 or x1 Only available with SP4 dual Die COMe PCIe 16 to COMe PCIe 31 can be bifurcated in x16 x8 or x4 3 5 1 AMD restrictions associated with the links There are a maxi...

Страница 33: ...imitation to maximum 7 ports Link Width at PCIE8 Disabled x1 2 x4 x8 Number of PCIE lanes for Link starting at COMe PCIE8 Link Width at PCIE9 Disabled x1 Number of PCIE lanes for Link starting at COMe...

Страница 34: ...ernet 10GbE Controller 3 7 1 Supported modes The 10GbE interface can be configured in three different modes in the UEFI menus Setting configuration are detailed in section AMD CBS Sub Menu items relat...

Страница 35: ...ds 68301 0000 04 4 DAC adaptor SFP DAC Direct connection using passive copper modules Needs 68301 0000 04 4 DAC adaptor KR SFP Not available on carrier Needs 68301 0000 3 2 Dual port CS4227 68301 0000...

Страница 36: ...OMe Features SPI Boot from an external SPI LPC Supported UART 2x UART RX TX Sleep Signals Supported SMBus Speed configurable default 100 k SMB 3 9 Kontron Features The following table lists the suppor...

Страница 37: ...Eval Carrier T7 GEN 2 68301 0000 04 4 ADA COMe T7 G2 4x10G DAC DEV TOOL COMe Type 7 Adapter Card 4x 10GbE Direct Attached Connection to SFP adapter to be used in combination with COMe Eval Carrier T7...

Страница 38: ...DDR4 2666 8 GByte E2 ECC DDR4 2666 8GB ECC E2 260P 1333MHz PC4 2666 SODIMM 97031 1627 BEP7 DDR4 2666 16 GByte E2 ECC DDR4 2666 16GB ECC E2 260P 1333MHz PC4 2666 SODIMM 97031 3227 BEP7 DDR4 2666 32 GB...

Страница 39: ...Description 38017 0000 00 5 COMe Mount KIT 5mm 1set Mounting Kit for 1 module including screws for 5mm connectors 38017 0000 00 0 COMe Mount KIT 8mm 1set Mounting Kit for 1 module including screws for...

Страница 40: ...Rise Time The input voltages should rise from 10 of nominal to within the regulation ranges within 0 1 ms to 20 ms There must be a smooth and continuous ramp of each DC input voltage from 10 to 90 of...

Страница 41: ...he Power Button to enable the ATX PSU setting PWR_OK to high level and powering on VCC The ATX PSU is controlled by the PS_ON signal which is generated by SUS_S3 through inversion VCC can be 8 5 V 20...

Страница 42: ...Suspend Standby States are not supported in Single Supply Mode Table 16 Single Supply Mode State PWRBTN PWR_OK V5_StdBy VCC G3 0 0 0 0 G3 S0 high open high OPEN connecting VCC S5 high open high OPEN V...

Страница 43: ...COMe bEP7 Module User Guide www kontron com 43 The minimum OFF time depends on the implemented PSU model and other electrical factors and needs to be measured individually for each case...

Страница 44: ...0 ms t 4 s typical 400 ms at low level Power Button Event Pressing the power button for at least 4 s will turn off power to the module Power Button Override 6 3 Power Good PWR_OK The COMe bEP7 provide...

Страница 45: ...e User Guide www kontron com 45 6 5 SM Bus Alert SMB_ALERT With an external battery manager present and SMB_ALERT Pin B15 connected the module always powers on even if BIOS switch After Power Fail is...

Страница 46: ...erating temperature defines two requirements the maximum ambient temperature with ambient being the air surrounding the module the maximum measurable temperature on any spot on the heatspreader s surf...

Страница 47: ...COM Express basic form factor Computer on Modules are Recognized by Underwriters Laboratories Inc Representative samples of this component have been evaluated by UL and meet applicable UL requirements...

Страница 48: ...tion The COM Express basic form factor Computer on Modules successfully passed shock and vibration tests according to IEC EN 60068 2 6 Non operating Vibration sinusoidal 10 Hz to 2000 Hz 0 15 mm 2 g I...

Страница 49: ...ommunications environment Other environmental stresses such as extreme altitude vibration salt water exposure lower MTBF values System MTBF hours 983529 h 40 C or 62 years Figure 6 MTBF Temperature De...

Страница 50: ...Module User Guide www kontron com 50 8 Mechanical Specification 8 1 Dimensions The dimensions of the module are 95 0 mm x 125 0 mm Figure 7 Module Dimensions CAD drawings are available at EMD Custome...

Страница 51: ...It works as a COM Express standard thermal interface to use with a heat sink or external cooling devices External cooling must be provided to maintain the heatspreader plate at proper operating tempe...

Страница 52: ...COMe bEP7 Module User Guide www kontron com 52 HOT Surface Do NOT touch Allow to cool before servicing...

Страница 53: ...User Guide www kontron com 53 8 2 1 Heatspreader Dimensions The following figure shows the heatspreader s dimensions and location on the module Figure 9 Heatspreader Location and Dimensions All dimens...

Страница 54: ...must be customized Table 20 Supported SPI boot flash types for 8 SOIC package Size Manufacturer Part Number Device ID 128 Mbit Micron MT25QU128ABA1E 0x20BA18 128 Mbit Winbond W25Q128JVSIG 0xEF7018 9 2...

Страница 55: ...re 10 Entering USB Key Partition Name a Alternatively there is a Linux version AFU tool available to update the SPI uses the same command line 4 On your terminal enter the following command Afu filena...

Страница 56: ...main program due to some fault condition such as a hang neglects to regularly service the watchdog writing a service pulse to it also referred to as kicking the dog petting the dog feeding the watchd...

Страница 57: ...s the processor entering the system management mode SMM As such specific BIOS code handles the interrupt The current BIOS handler for the watchdog SMI currently does nothing For particular needs conta...

Страница 58: ...When set to Auto the fused maximum cTDP of the SoC is used When set to Manual can set customized cTDP value with option cTDP 2 Advanced AMD CBS NBIO Common Options cTDP Customized cTDP value in Watts...

Страница 59: ...s on the effective use of C states and P states Disabling C states greatly reduces the performance benefit of APM as active cores would not be able to leverage the reduced power of idle cores APM can...

Страница 60: ...Voltage Depending on the Used Ethernet MAC Phy WakeOnLan must be enabled in BIOS setup and driver options 9 9 Fan Connector J7 Figure 11 3 pin Fan Connector Table 22 3 pin Fan Connector Pin Signal De...

Страница 61: ...AT All addresses not mentioned in this table should be available We recommend that you do not use I O addresses below 0100h with additional hardware for compatibility reasons even if available Table 2...

Страница 62: ...0091 DMA Controller No Fixed 0092 Reset Generator No Fixed 0093 009F DMA Controller No Fixed 00A0 00BD Interrupt Controller No Fixed 00C0 00D1 DMA Controller No Fixed 00DE 00DF DMA Controller No Fixe...

Страница 63: ...Other I O addresses are dynamically allocated for PCI devices and not listed here Refer to your OS documentation on how to determine I O addresses usage 10 4 I2C Bus Table 25 I2C Bus Port Addresses 8...

Страница 64: ...ddress for all devices 7 bit SMBus addresses shows the device address without Bit0 Table 26 Designated I O Port Addresses 8 bit Address 7 bit Address Device Comment SMBus 58h 0x2C HWM NCT7802Y non ECC...

Страница 65: ...Me Connector Pinout To protect external power lines of peripheral devices make sure that the wires have the right diameter to withstand the maximum available current the enclosure of the peripheral de...

Страница 66: ..._ALERT1 USB_SSRX2 USB_SSTX2 10 GBE0_MDI1 LPC_CLK ESPI _CK USB_SSRX2 USB_SSTX2 11 GND FIXED GND FIXED GND FIXED GND FIXED 12 GBE0_MDI0 PWRBTN USB_SSRX3 USB_SSTX3 13 GBE0_MDI0 SMB_CK USB_SSRX3 USB_SSTX3...

Страница 67: ...X 3 28 S ATA_ACT None on EPYC 3000 GND FIXED GND GND 29 RSVD RSVD 10G_KR_RX 2 10G_KR_TX 2 30 RSVD RSVD 10G_KR_RX 2 10G_KR_TX 2 31 GND FIXED GND FIXED GND FIXED GND FIXED 32 RSVD SPKR None on EPYC 3000...

Страница 68: ...USB1 10G_PHY_M DC_SCL1 10G_PHY_M DIO_SDA1 46 USB0 USB1 10G_PHY_M DC_SCL0 10G_PHY_M DIO_SDA0 47 VCC_RTC ESPI_EN 10G_INT0 10G_INT1 48 RSVD USB0_HOST_P RSNT GND GND 49 GBE0_SDP SYS_RESET 10G_KR_RX 0 10G...

Страница 69: ...D WAKE0 PCIE_RX20 PCIE_TX20 67 GPI2 WAKE1 RAPID_SHU TDOWN GND 68 PCIE_TX0 PCIE_RX0 PCIE_RX21 PCIE_TX21 69 PCIE_TX0 PCIE_RX0 PCIE_RX21 PCIE_TX21 70 GND FIXED GND FIXED GND FIXED GND FIXED 71 PCIE_TX8 P...

Страница 70: ...GND FIXED GND FIXED GND FIXED GND FIXED 91 SPI_POWER NCSI_CLK_IN PCIE_RX28 PCIE_TX28 92 SPI_MISO NCSI_RXD1 PCIE_RX28 PCIE_TX28 93 GPO0 NCSI_RXD0 GND GND 94 SPI_CLK NCSI_CRS_DV PCIE_RX29 PCIE_TX29 95...

Страница 71: ...n Row A Row B Row C Row D 105 VCC_12V VCC_12V VCC_12V VCC_12V 106 VCC_12V VCC_12V VCC_12V VCC_12V 107 VCC_12V VCC_12V VCC_12V VCC_12V 108 VCC_12V VCC_12V VCC_12V VCC_12V 109 VCC_12V VCC_12V VCC_12V VC...

Страница 72: ...BIOS comes with a Setup program that provides quick and easy access to the individual function settings for control or modification of the uEFI BIOS configuration The Setup program allows for access t...

Страница 73: ...ETURN RETURN key executes a command or selects a submenu Minus key selects the next lower value within a field Plus key selects the next higher value within a field F1 F1 key invokes the General Help...

Страница 74: ...t Logs The currently active menu and the currently active uEFI BIOS Setup item are highlighted in white Use the left and right arrow keys to select the Setup menus Each Setup menu provides two main fr...

Страница 75: ...ions and describes the content Default settings are in bold Some functions contain additional information Table 29 Main Setup Menu Sub screens Sub Screen Description BIOS Informatio n Read only field...

Страница 76: ...COMe bEP7 Module User Guide www kontron com 76 Sub Screen Description System Date Displays the system date Week Day mm dd yyyy System Time Displays the system time hh mm ss...

Страница 77: ...nced configuration and Kontron specific configurations Setting items on this screen to incorrect values may cause system malfunctions Figure 16 Advanced Setup Menu The following tables provides a desc...

Страница 78: ...Enablement Disagree Agree NB Configuratio n IOMMU Enables or Disables IOMMU Disabled Enabled Auto Concurrent Training Enables or Disables Concurrent Training Disabled Enabled Auto NBIO Internal Poiso...

Страница 79: ...ll not take effect Only available when CLDO_VDDP Control is set to Manual 0 1 HD Audio Enable Enables or disables HD Audio Disabled Enabled Auto Block PCIe Loopback Block PCIe Loopback mode for hot pl...

Страница 80: ...ATA Device Sleep Port 0 Enables or disables Aggressive SATA Device Sleep on port 0 Disabled Enabled Auto DevSleep0 Port Number DEVSLP port 0 0 1 Aggressive SATA Device Sleep Port 1 Enables or disables...

Страница 81: ...Always Off Always On Reserved Previous XGBE Configuratio n Options AMD XGBE Controller X Enable or Disable Ethernet Controller X Enabled Disabled Ethernet PHY This options allows to select external P...

Страница 82: ...D If external PHY connected using MDIO sideband interface MDIO ID of the PHY If MDIO is not used by this port set this to 0 0 Miscellaneo us Options Boot Timer Enable Boot Timer enable Enable force PM...

Страница 83: ...n Further Sub Screens Description NTB active on PCIeCore NTB enable on PCIe Core Auto Core0 Core1 NTB Mode Select NTM Mode Core 0 Port 0 Auto NTB Disabled NTB Primary NTB Secondary NTB Random Link spe...

Страница 84: ...e Gen2 Additional information AMD EPYC Embedded 3000 max PCIe speed is Gen3 12 4 3 Configuration Sub Menu Table 32 Configuration Sub Screens Sub Screen Description iSCSI Initiator Name Enter the world...

Страница 85: ...es Health Status for the controller driver Intel R I210 Gigabit Network Connection 12 4 6 Trusted Computing Sub Menu Table 35 Trusted Computing Sub Screens Sub Screen Further Sub Screens Description S...

Страница 86: ...for Win8 Win10 and TCG_2 supports TCG2 protocol and event format for Win10 or later TCG_1_2 TCG_2 Physical Presence Spec Version Select to tell OS to support either PPI Spec 1 2 or 1 3 Note Some HCK...

Страница 87: ...ntron com 87 Sub Screen Second Level Sub screen Description Enable ACPI Auto Configuration Enables or disables ACPI auto configuration If enabled the system uses generic ACPI settings that may not fit...

Страница 88: ...peed between 1 kHz and 400 kHz For a default system 200KHz is appropriate Onboard I2C Mode Sets the I2C onbaord mode Mulitmaster BusClear Sleep Button Mode Shows or hides Sleep Button inside ACPI OS D...

Страница 89: ...Disable will totally stop the fan a Disable stops fan b Manual manually sets the fan c Auto Hardware monitor controls cooling similar to ACPI based Active Cooling without producing a software load to...

Страница 90: ...perature CPU Temperature Additional information External Fan An external fan can be connected to baseboard The external fan control lines are routed via the COMe connector 5 0 V Standby Read only fiel...

Страница 91: ...A parity bit can be sent with the data bits to detect transmission errors Even parity bit is 0 if the num of 1 s in the data bits is even Odd parity bit is 0 if the num of 1 s in the data bits is odd...

Страница 92: ...sole Redirection Settings Redirection COM Port Selects a COM port to display redirection of legacy OS and legacy OPROM messages COM0 COM1 Resolution On legacy OS the number of rows and columns support...

Страница 93: ...ng or noisy lines may require lower speeds 9600 19200 57600 115200 Flow Control Flow control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signa...

Страница 94: ...ed on the Setup page after system restarts Use Automatic Settings IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 7 9 10 11 12 IO 2F8h IRQ 3 4 5 7 9 10 11 12 IO 3E8h IRQ 3 4 5 7 9 10 11 12 IO 2E8h IRQ 3 4 5 7 9 10 11...

Страница 95: ...reen Description Further Sub Screens Description IO 3F8h IRQ 3 4 5 7 9 10 11 1 IO 2F8h IRQ 3 4 5 7 9 10 11 12 IO 3E8h IRQ 3 4 5 7 9 10 11 12 IO 2E8h IRQ 3 4 5 7 9 10 11 12 Read only field WARNING Disa...

Страница 96: ...Level Sub screen Description Read only fields USB Configuration UBS Module Version USB Controllers and USB devices Legacy USB Support Enables legacy USB support Enable Supports legacy USB Auto disabl...

Страница 97: ...ub screen Description Network Stack Enables or disables the UEFI network stack Enabled Disabled Additionnal information This field needs to be enabled in order for the rest of the fields to be display...

Страница 98: ...g BIOS services ALWAYS Does not allow disabling GA20 This option is useful when any RT code is executed above 1 MB Upon Request Always INT19 Trap response BIOS reaction on INT19 traping by Option ROM...

Страница 99: ...Debug Port Table Enabled Disabled Debug Port Table 2 Enabled Disabled 12 4 19 NVMe Configuration Sub Menu Table 48 NVMe Configuration Sub Screens Sub Screen Read only field Acts as a message showing...

Страница 100: ...ons listed below and describes the content Default settings are in bold Some functions contain additional information Table 50 Chipset Sub screens and Functions Sub Screen Second level Sub Screen Desc...

Страница 101: ...ecurity settings Figure 18 Security Setup Menu The following table shows Security sub screens and functions Default settings are in bold Table 51 Security Setup Menu Functions Function Description Adm...

Страница 102: ...change takes effect after reboot Yes No Enroll Efi Image Allow the image to run in Secure Boot Mode Enroll SHA256 hash of the binary into Authorized Signature Database db Platform Key Enroll Factory...

Страница 103: ...in the user being locked out of the system If the system cannot be booted because the User Password or the Supervisor Password are not known clear the uEFI BIOS settings or contact Kontron Support for...

Страница 104: ...ns UEFI Built in EFI shell Disabled Additionnal information When Enabling UEFI PXE support in BIOS Advanced Network Stack Configuration the Boot menu will only show UEFI AmdXgbe Network Driver x devic...

Страница 105: ...after saving changes Discard Changes and Exit Exits system setup without saving changes Save Changes and Reset Resets system after saving changes Discard Changes and Reset Resets system setup without...

Страница 106: ...o far as User Defaults Restore User Defaults Restores User Defaults to all setup options Boot Override Options UEFI Built in EFI shell Attempts to launch the built in EFI Shell Launch EFI Shell from f...

Страница 107: ...ional information Table 54 Event Logs Setup Menu Functions Function Sub FunctionsDescription Change Smbios Event Log Settings Enabling and disabling options Smbios Event Log Enables or disables all th...

Страница 108: ...t already been converted to legacy Enabled Disabled Convert OEM Codes Enables or disables the converting of EFI status codes to standard Smbios types Note Not all may be translated Enabled Disabled Ad...

Страница 109: ...running mode 1 1 2 Device mapping table Fs0 HardDisk Alias hd33b0b0b fs0 Acpi PNP0A03 0 Pci 1D 7 Usb 1 0 Usb 1 0 HD Part1 Sig17731773 4 Press the ESC key within 5 seconds to skip startup nsh script i...

Страница 110: ...of the attached FAT formatted disk drive 3 If none of the startup scripts are present or the startup script terminates then the default boot order is continued 12 11 2 Create a Startup Script Startup...

Страница 111: ...rst detected disc drive fs0 fs0 bootme nsh 12 13 Firmware Update Firmware updates are typically delivered as a ZIP archive containing only the firmware images The content of the archive with the direc...

Страница 112: ...Addition connected hardware full description of hardware set up The serial number can be found on the Type Label located on the product s rear side Be ready to explain the nature of your problem to th...

Страница 113: ...or Kontron Europe GmbH and fill out the form Take care to include a short detailed description of the observed problem or failure and to include the product identification Information Name of product...

Страница 114: ...nding control over to the operating system Carrier Board An application specific circuit board that accepts a COM Express Module AMD CBS AMD Common BIOS Specification AMD SoC related options Compact M...

Страница 115: ...tutes a legacy device Some definitions include IDE as a legacy device LAN Local Area Network LPC Low Pin Count Interface a low speed interface used for peripheral circuits such as Super I O controller...

Страница 116: ...the PS2 system ROM Read Only Memory a legacy term often the device referred to as a ROM can actually be written to in a special mode Such writable ROMs are sometimes called Flash ROMs BIOS is stored i...

Страница 117: ...andard for hard disks SM Bus System Management Bus Super I O An integrated circuit typically interfaced via the LPC bus that provides legacy PC I O functions including PS2 keyboard and mouse ports ser...

Страница 118: ...ts and tailor made solutions based on highly reliable state of the art embedded technologies Kontron provides secure and innovative applications for a variety of industries As a result customers benef...

Отзывы: