Fig. 4
TO STOP THE ENGINE, PROCEED AS FOLLOWS
TO STOP THE ENGINE, PROCEED AS FOLLOWS
1. Turn off all devices.
2. Allow the generator to run idle for approx. 1-2 minutes.
3. For dual fuel models close LPG supply valve on LPG bottle.
4. For model KS 5500iE
G set the FUEL CHOICE knob to the “OFF” p
osition.
5. For models KS 2100i S, KS 3100i S, KS 2100iG S, KS 3100iG S Turn the multifunctional engine switch to the “OFF” position. For models
KS 5500iES ATSR, KS 5500iEG S press the ELECTRIC START button, then press MAIN POWER button to “OFF” position
6. Unplug the devices.
7. After the generator stops, allow it to cool down and close the air vent on the fuel cap (set to OFF, as shown in Fig. 4, for models
KS 2100i S, KS 2100iG S, KS 3100i S, KS 3100iG S - when switching off gasoline operation).
Fig. 5
CHARGING AN EXTERNAL 12 V BATTERY
CHARGING AN EXTERNAL 12 V BATTERY
1. Start the engine.
2. Connect the red wire to the positive (+) terminal of the battery.
3. Connect the black wire to the negative (-) terminal of the battery.
4. Connect the wire to a 12V/8.3A DC socket on the control panel of the generator.
5. To start charging the battery, set ECON to “OFF”.
6. Turn the 12 V DC fuse to the “ON” position.
If the DC protector turns off again, stop charging the battery because the charging current is too high. Do not charge batteries if their
current consumption is more than 8.3 A (depending on the generator model).
IMPORTANT!
- Make sure the ECON mode is off while the battery is being charged.
- Be sure to connect the charger’s red wire to the plus (+) terminal of the battery and the black wire to
the minus (-) terminal of the battery. Do not swap the terminals.
- Connect the charger to the battery terminals securely so that they are not disconnected due to motor
vibrations or other actions.
- The 12 V socket can only be used as a backup source for recharging batteries and shall not be deemed
as a full-featured battery charger.
- The DC protector turns off automatically if the current is higher than the rated current while the battery
is being charged. To restore battery charging, turn on the DC fuse by pressing the “ON” button.
Never smoke or interrupt battery connections to the generator while
the battery is being charged.
ATTENTION – DANGER!
MAINTENANCE
9
This manual compliance! You can find a list of service center addresses on the website of exclusive importer:
www.ks-power.de/en
Inverter generators from Könner & Söhnen are equipped with lithium
batteries with an operating voltage similar to conventional lead-acid
batteries.
IMPORTANT!
When the generator is running, the battery is charged automatically. If it is necessary to charge the
battery with an external device, we recommend using the KS B1A charger or the charger for charging
lead-acid motorcycle batteries with a nominal voltage of 12V with a charge current of not more than 2A.
www.ks-power.de/en
|
23
Содержание KS 2100i S
Страница 2: ...DEUTSCH 2 13 POLSKI 52 66 FRAN AIS 26 38 ENGLISH 14 25 67 79 ROM N 39 51 www ks power de 1...
Страница 68: ...KS 2100i S KS 2100iG S KS 3100i S KS 3100iG S KS 5500iES ATSR KS 5500iEG S UA www ks power de 67...
Страница 79: ...11 50 10 1 2 3 4 5 6 12 1 2 3 A5 RTC 4 0 7 0 8 5 13 14 1 2 3 4 15 www ks power com ua 78...
Страница 80: ...17 18 K nner S hnen 16 20 C 40 10 KS 5500iES ATSR KS 5500iEG S www ks power com ua 79...
Страница 81: ......