Do not connect two or more devices at a time. The start-up of many
devices requires high power. Devices should be connected one at a
time according to their power rating.
ATTENTION – DANGER!
1. Check oil level.
2. For model KS 5500iEG S - set the fuel switch FUEL CHOICE to LPG.
The inverter generators KS 2100iG S, KS 3100iG S use smart fuel switching
system. In order to use LPG as fuel you need to connect a hose to the
corresponding connector on the generator panel and open the valve on
the gas cylinder. The solenoid valve will automatically shut off the gasoline
supply from the gasoline tank.
Disconnect the load from the generator before changing fuel. The
ECONOMY MODE switch must be in the “OFF” position. Gasoline re-
mains in the carburetor make it difficult to start the engine on LPG.
IMPORTANT!
Let the generator run out of gasoline until it stops. When switching from gasoline to LPG operation, the
generator may be unstable during the first 2-3 minutes and the low voltage protection may trip. If the red
indicator (overload indicator) lights up in 2-3 minutes after running the generator on LPG when it is
running stable, press the AC Reset BUTTON on a panel of generator to restore voltage supply. To do this,
close the fuel valve with the generator running and wait until the generator stops completely. To do this,
close the fuel valve while the generator is running (set the FUEL CHOICE knob to OFF) to stop the gasoline
supply to the fuel system for the KS 5500iE G, wait for the generator to come to a complete stop. Then
start the generator on LPG. You can also drain the remaining gasoline from the carburetor before starting
the generator on LPG.
3. Connect the LPG hose to the LPG input on the generator control panel (connect end
A
of a hose to the LPG input on the generator
control panel, as shown in Fig. 3.).
4. Connect the hose end with the reducer to the gas cylinder (connect end
B
of hose to the gas cylinder, as shown in Fig. 4).
5. Open the gas valve on the cylinder, making sure that no gas is leaking.
6. Press the pressure relief valve on the reducer 2-3 times (see Fig. 3).
7. When using for the first time, fill the gas line with gas by turning the key (pressing start button) to the “OFF” position and slowly pull
the starter handle to the full cord length 2 to 3 times.
8. For manual start KS 5500iE G model, press MAIN POWER button to “ON” position, pull the manual starter until a slight resistance is
felt, then pull it toward you relatively sharply. Slowly return the manual starter by hand, do not release it abruptly. For electric start -
press MAIN POWER button to “ON” position, then press the ELECTRIC START button. If the engine does not start on the first try, press the
ELECTRIC START button again in 3-5 seconds.
9. To start KS 2100iG S, KS 3100iG S models, turn the Multifunctional engine switch to the “START” position (fig. 2). Pull the handle of
manual starter until a slight resistance is felt, then pull it relatively sharply. Slowly return the handle manual starter by hand, do not
release it abruptly. Turn the Multifunctional engine switch to the “RUN” position (fig. 2).
A
B
Fig. 3
RUNNING GENERATOR ON LPG (KS 2100iG S, KS 3100iG S , KS 5500iEG S)
RUNNING GENERATOR ON LPG (KS 2100iG S, KS 3100iG S , KS 5500iEG S)
Useful tip: to ensure long-term operation of the generator engine, it is
important to observe the following tips:
- Before connecting the load, allow the engine to run for 1-2 minutes to warm it up.
- When disconnecting the load after lengthy operation, do not turn off the generator. Allow the generator
to run idle for 1-2 minutes so that it cools down.
IMPORTANT!
Fig. 1
Fig. 2
FOR MODEL
FOR MODEL
KS 5500
KS 5500iiES ATSR
ES ATSR
1. Check oil level.
2. Check fuel level.
3. Turn the fuel valve handle to the “ON” position (OPEN).
4. For manual start press MAIN POWER button to “ON” position, pull the handle of manual
starter until a slight resistance is felt, then pull it relatively sharply. Slowly return the manual
starter handle by hand, do not release it abruptly.
4.1. For electric start – press MAIN POWER button to “ON” position, then press the ELECTRIC
START button.
5. For manual start pull the manual starter until a slight resistance is felt,
then pull it toward you relatively sharply. Slowly turn the manual starter
by hand, do not release it abruptly.
6.
Turn the Multifunctional engine switch to the “RUN” position
.
www.ks-power.de/en
|
21
Содержание KS 2100i S
Страница 2: ...DEUTSCH 2 13 POLSKI 52 66 FRAN AIS 26 38 ENGLISH 14 25 67 79 ROM N 39 51 www ks power de 1...
Страница 68: ...KS 2100i S KS 2100iG S KS 3100i S KS 3100iG S KS 5500iES ATSR KS 5500iEG S UA www ks power de 67...
Страница 79: ...11 50 10 1 2 3 4 5 6 12 1 2 3 A5 RTC 4 0 7 0 8 5 13 14 1 2 3 4 15 www ks power com ua 78...
Страница 80: ...17 18 K nner S hnen 16 20 C 40 10 KS 5500iES ATSR KS 5500iEG S www ks power com ua 79...
Страница 81: ......