4 .4 Basic Scanning Mode
138
Item
Functions
[THI]
THI settings for B- and M-mode
[Param . Disp .]
Sets whether to display parameters during dual mode (displaying images side-by-side) .
•
When it is set to [Off] or [Trans.], the ultrasound image is also displayed even in the parameter
display area .
• When it is set to [Trans .], both the ultrasound image and parameters are displayed .
[TD Guide]
Sets Show / Hide of the scale marked on the transducer on the screen .
• Enabled when the biopsy guide display is set to OFF .
• This is enabled when a linear transducer or MC10-3 transducer is equipped .
[Auxiliary Line]
Sets and displays an auxiliary line(s) in the depth direction .
• The interval between auxiliary lines varies depending on the display depth .
• Enabled when the biopsy guide display is set to OFF .
[Aux . Line Type]
Sets the display range for the auxiliary line .
[Sound Speed]
• Sets the velocity used for incoming data .
[B Filter]
Sets the internal parameters of B images .
[UD Flip]
Reverses the image in the vertical direction .
• M-mode is also simultaneously operated .
[B iXRET]
Sets a process to improve resolution for B-mode .
HINT
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
• [Dual Layout] can be assigned to the mode button area . In that case, you can select [L/R] or [U/D 1] only .
Refer to "[Mode Button] customize" in "Menu Customize Screen" of the "Operation Manual: Applications" .
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
Содержание SONIMAGE HS2
Страница 1: ...EN 01...
Страница 2: ......
Страница 6: ...6...
Страница 7: ...7 Introduction...
Страница 41: ...41 For all product inquiries contact your service representative Support...
Страница 42: ...42...
Страница 43: ...43 Chapter 1 Product Overview...
Страница 68: ...68...
Страница 69: ...69 Chapter 2 Before Examination...
Страница 84: ...84...
Страница 85: ...85 Chapter 3 Starting Examination...
Страница 122: ...122...
Страница 123: ...123 Chapter 4 Diagnosis Mode...
Страница 181: ...181 Chapter 5 Common Function in Ultrasound Images...
Страница 219: ...219 Chapter 6 Reviewing Printing and Transferring Images...
Страница 232: ...232...
Страница 233: ...233 Chapter 7 Maintenance Inspection...
Страница 243: ...243 Chapter 8 Transducer and Biopsy...
Страница 270: ...270...
Страница 271: ...271 Chapter 9 MI TI...
Страница 283: ...283 Chapter 10 Acoustic Output...
Страница 286: ...286...
Страница 287: ...287 Chapter 11 Others...
Страница 305: ...305...
Страница 306: ...306...
Страница 307: ......