224
416739/A
13
For each channel:
a
Start raw data recording.
b
Allow the data recording to run approximately five minutes.
c
Stop raw data recording.
d
Use a file manager, and verify that the recorded file(s) have been saved on the
chosen disk.
e
Verify that the playback is operational.
14
Select
Help
on the top bar.
a
Make sure that the online help opens on its start page.
b
Close the online help.
Result
Requirements
Results
The latest software version is installed.
Each transducer is installed with the correct parameters.
Each transceiver channel is operational.
The ES80 detects and displays a bottom echo in each echogram.
Date and signature:
Related topics
Test procedures, page 221
Setting to work, page 153
Measuring noise in passive operating mode
Low noise is a key factor for high quality and reliable measurements. The performance of
the ES80 will always be limited by different noise sources. The noise is measured while the
ES80 operates in
Passive
mode with the transmit pulses disabled.
Prerequisites
The ES80 hardware units are installed as specified in this manual.
• The ES80 system is turned on and operates normally.
Caution
You must never set the ES80 to "ping" unless the transducer is submerged in water. The
transducer may be damaged if it transmits in open air.
Simrad ES80 Installation Manual
Содержание Simrad ES80
Страница 1: ...kongsberg com simrad Simrad ES80 INSTALLATION MANUAL ...
Страница 2: ......
Страница 25: ...416739 A 23 Related topics Scope of supply page 21 Simrad ES80 page 11 Simrad ES80 ...
Страница 278: ...276 416739 A 201575 Transducer connector assembly and wiring Simrad ES80 Installation Manual ...
Страница 309: ......
Страница 310: ... 2020 Kongsberg Maritime ISBN 978 82 8066 187 6 ...
Страница 311: ......
Страница 312: ...Installation Manual Simrad ES80 ...