416739/A
173
echo data that you export. If you do not have a computer keyboard connected to your
ES80 system, select the
Keyboard
button to open an on-screen keyboard.
7
Select mounting method.
8
Specify the orientation of the transducer beam.
• If the transducer has been installed with the transducer face in a horizontal position,
the beam is pointing straight down. You must then select
Vertical
orientation.
• Set
Orientation
to
Horizontal
if the transducer has been mounted with its face
upright for horizontal beams.
9
If relevant for your transducer installation, provide the accurate physical location of the
transducer with reference to the vessel’s coordinate system.
Use the centre of the transducer face as reference, and define the offset values related
to the
Ship Origin
.
a
Select the offset value on the X axis (fore-and-aft direction) from the
Ship Origin
.
Adjust with a positive value for X if the transducer is located ahead of the ship
origin.
b
Select the offset value on the Y axis (athwartship) from the
Ship Origin
. Adjust
with a positive value for Y if the transducer is located on the starboard side
of the ship origin.
c
Select the offset value on the Z axis (vertical) from the
Ship Origin
. Adjust with a
positive value for Z if the transducer is located under the ship origin.
10
Optional
: Select
Connected as single beam transducer
.
A split-beam transducer with four sectors can be physically connected to the transceiver
to work as a single-beam transducer. If you have made this connection, you must tick
this box to make the ES80 operate accordingly. The relevant wiring is described in
the ES80
Installation Manual
.
This option is only available when you are installing a split-beam transducer.
11
Select
Add
to save the information you have provided.
The transducer is added to the list in the
Installed Transducers
box.
12
Repeat for each transducer that you wish to install.
13
Continue your work in the
Installation
dialog box, or select
OK
to close it.
Result
Once a transducer has been installed, it is listed in the
Installed Transducers
box. To see the
information you have collected about the transducer, select the relevant transducer in the list.
The
Edit
functionality on the
Transducer Installation
page makes it possible to change
the information you have provided for the transducer. You cannot change the model
Содержание Simrad ES80
Страница 1: ...kongsberg com simrad Simrad ES80 INSTALLATION MANUAL ...
Страница 2: ......
Страница 25: ...416739 A 23 Related topics Scope of supply page 21 Simrad ES80 page 11 Simrad ES80 ...
Страница 278: ...276 416739 A 201575 Transducer connector assembly and wiring Simrad ES80 Installation Manual ...
Страница 309: ......
Страница 310: ... 2020 Kongsberg Maritime ISBN 978 82 8066 187 6 ...
Страница 311: ......
Страница 312: ...Installation Manual Simrad ES80 ...