When the ambient temperature drops, the capacity of the battery will also drop. Maintain the battery charging
rate as close as possible to 100%. Insulate it against cold temperature to ensure that the machine can be
started easily in the next morning.
REMARK
Measure the gravity of the electrolyte and calculate the charging rate from the following conversion table.
Electrolyte Temper-
ature
Charging Rate (%)
20 °C
0 °C
–10 °C
–20 °C
100
1.28
1.29
1.30
1.31
90
1.26
1.27
1.28
1.29
80
1.24
1.25
1.26
1.27
75
1.23
1.24
1.25
1.26
• When the ambient temperature is low, the capacity of the battery considerably drops. Cover it, or remove it
from the machine to place it in the warm place. Restore it again before the operation.
• If the electrolyte level is low, add distilled water in the morning before beginning the work. Do not add water
after the day's work to prevent diluted electrolyte in the battery from freezing during the night.
PRECAUTIONS AFTER DAILY WORK COMPLETION
To prevent mud, water, or the undercarriage from freezing and making it impossible for the machine to move on
the following morning, observe the following precautions.
• Remove all the mud and water from the machine body. In particular, wipe the hydraulic cylinder rods clean
to prevent damage to the seal caused by mud, dirt, or drops of water on the rod from getting inside the seal.
• Place the machine on a firm, dry ground.
If this is impossible, park the machine on boards.
The boards prevent the tracks from freezing to the ground, and allow the machine to move the next morn-
ing.
• Open the drain valve at the bottom of the fuel tank to drain the water accumulated in the fuel system and
prevent it from freezing.
• In cold weather condition, add DEF to the defined level strictly. If adding more than the defined level, it may
expand to break the devices in the tank when it freeze.
If DEF tank level is lower than the defined level for the cold weather, DEF may freeze easily to damage the
parts in DEF system. If the filler cap freeze, de freeze and open.
• The battery function decreases remarkably at low temperature.
Cover it, or remove it from the machine to place it in the warm place. Restore it again before the operation.
• If the electrolyte level is low, add distilled water in the morning before beginning the work.
Do not add water after the day's work to prevent diluted electrolyte in the battery from freezing during the
night.
AFTER COLD WEATHER SEASON
When the season changes and the weather becomes warmer, do as follows.
Replace the fuel and oil for all equipment with the ones of the specified viscosity. For details, see “RECOM-
MENDED FUEL, COOLANT, AND LUBRICANT (7-4)”.
If the machine is parked for long time in the cold weather condition, quality of DEF may be affected by repeated
freeze, ask your Komatsu distributor to inspect.
OPERATION
COLD WEATHER OPERATION
3-245
Содержание HM400-5
Страница 2: ......
Страница 23: ...LOCATION OF SAFETY LABELS SAFETY SAFETY LABELS 2 5 ...
Страница 24: ...SAFETY LABELS SAFETY 2 6 ...
Страница 60: ......
Страница 61: ...OPERATION Please read and make sure that you understand the SAFETY section before reading this section 3 1 ...
Страница 322: ......
Страница 323: ...MAINTENANCE Please read and make sure that you understand the SAFETY section before reading this section 4 1 ...
Страница 409: ...SPECIFICATIONS 5 1 ...
Страница 411: ...SPECIFICATIONS SPECIFICATIONS 5 3 ...
Страница 412: ......
Страница 413: ...ATTACHMENTS AND OP TIONS Before reading this chapter read and understand the SAFETY 6 1 ...
Страница 430: ......
Страница 431: ...REPLACEMENT PARTS 7 1 ...
Страница 446: ...HM400 5 ARTICULATED DUMP TRUCK Form No EENAM03380 2015 KOMATSU All Rights Reserved Printed in Belgium 09 2015 ...