2.
Turn the battery disconnect switch to OFF position (O).
3.
Remove battery cover (2) by using a small crane, etc.
4.
Remove bolt (3).
5.
Remove plastic sheet (4).
6.
When removing the battery cables, first remove the ground
cable (normally connected to the negative (-) terminal).
If any tool touches between the positive (+) terminal and
the chassis, there is a hazard of sparks being generated.
Loosen the terminal nut and disconnect the wiring from the
battery.
7.
After replacing the battery, secure it with the battery hold-
down fittings.
Tightening torque (4 places)
First nuts (A): 4 to 6 Nm{0.4 to 0.6 kgm}
Second nuts (B): 30 to 50 Nm{3.1 to 5.1 kgm}
8.
When installing the battery cables, connect the ground cable last.
Insert the terminal hole into the battery and tighten the nut.
Tightening torque: 9.8 to 11.8 Nm{1.0 to 1.2 kgm}
9.
Install battery cover (2) by using a small crane, etc.
10. Turn the battery disconnect switch to ON position (I).
11. Close inspection cover (1) on the left side of the battery cover.
TROUBLES AND ACTIONS
OPERATION
3-242
Содержание D155AX-8E0
Страница 2: ......
Страница 11: ...Do not repeatedly handle and lift loads FOREWORD VIBRATION LEVELS 1 9...
Страница 13: ...Evaluation height 1 2m above the ground Scale interval of the circles is 1 m FOREWORD INTRODUCTION 1 11...
Страница 24: ......
Страница 63: ...OPERATION Please read and make sure that you understand the SAFETY section before reading this section 3 1...
Страница 312: ......
Страница 313: ...MAINTENANCE Please read and make sure that you understand the SAFETY section before reading this section 4 1...
Страница 397: ...SPECIFICATIONS 5 1...
Страница 403: ...HANDLE HEADREST Keep the headrest inserted to the end ATTACHMENTS AND OPTIONS HANDLE HEADREST 6 5...
Страница 404: ......
Страница 405: ...REPLACEMENT PARTS 7 1...
Страница 420: ...D155AX 8E0 BULLDOZER Form No EENAM03780 2019 KOMATSU All Rights Reserved Printed in Belgium 04 2019...