Vers. 062721
71
Binary tables for sequence and program selection
Refer to the tables below for sequence or program selection via CN3, where “1” refers to an
24VDC signal with respect to the GND pin and “0” refers to no signal.
The REMOTE PR or REMOTE SEQ setting (General Settings >
) must be active for the input selection to work.
The outputs pins 25-33 will always be active irrespective of the REMOTE PR/SEQ setting,
following the same binary code pattern for the input side reported below.
Sequence
BIT3 SEQ
PIN 5
BIT2 SEQ
PIN 4
BIT1 SEQ
PIN 3
-
0
0
0
A
0
0
1
B
0
1
0
C
0
1
1
D
1
0
0
E
1
0
1
F
1
1
0
G
1
1
1
H