Vers. 062721
23
Main Screen – Sequence Mode
(1)
Sequence (“SEQ”) currently selected
Touch to select a different sequence (A through H).
(2)
Screw count
Counter: screws successfully completed / number of screws in current program
Note: does not appear if NUMBER OF SCREWS parameter is set to zero. Number of
screws is also referred to as “batch size” in the industry.
(3)
Main Menu Button (
≡)
Tap
to enter the main menu
(4)
Angle value
Measured angle value for last screw, in degrees.
(5)
Angle target
Shows the target angle when in angle control mode, or the min/max angle bounds when
in torque control mode or timed rundown mode, for the current program, in degrees.
(6)
Menu lock status
White background means no password is required to access the configuration menu.
Red background means the configuration menu is password protected.
(7)
Reset (“RST”) button
Screw/Program/Sequence Reset (“RST”) button. Presence and function of this button
depend on the corresponding settings in the GENERAL SETTINGS menu.
(8)
Torque charts
Tap to display the Torque-time and torque-angle charts for last screw.
Содержание K-DUCER
Страница 1: ...KDU1 KDU1A Torque range 0 1 70 Nm OPERATOR MANUAL...
Страница 22: ...Vers 062721 22 Main Screen Program Mode navigation tree...
Страница 25: ...Vers 062721 25 Main Screen Sequence Mode navigation tree...
Страница 32: ...Vers 062721 32 PROGRAMS menu tree...
Страница 33: ...Vers 062721 33...
Страница 34: ...Vers 062721 34...
Страница 44: ...Vers 062721 44 SEQUENCE SETTINGS menu tree...
Страница 53: ...Vers 062721 53 USB menu tree...
Страница 59: ...Vers 062721 59...