Vers. 062721
66
INPUT SIDE (PINS 1-22)
The input signals must be driven by a +24VDC potential with respect to pin 22 (GND).
A +24VDC potential is provided for convenience at pin 21 (24V DC).
When driving the inputs via an automated machine or PLC, it is recommended to
program a delay of at least 30ms between each change of input signals.
Pulse signals (IN AGN, IN RST, ESC-EXT, OK-EXT) should be kept active for at least
30ms in order to be properly processed.
PIN
NAME
FUNCTION
1
NOT USED
2
NOT USED
3
BIT1 SEQ
Least significant bit to select the Sequence (see charts below)
4
BIT2 SEQ
REMOTE SEQ setting (General Settings >
) must be
ON to enable sequence selection via input pins 3-4-5
5
BIT3 SEQ
Most significant bit to select the Sequence (see binary tables below)
6
BIT1 PR
Least significant bit to select the Program (see binary tables below)
7
BIT2 PR
REMOTE PR setting (General Settings >
) must be ON to
enable program selection via input pins 6-7-8-9-10-11
8
BIT3 PR
9
BIT4 PR
10
BIT5 PR
11
BIT6 PR
Most significant bit to select the Program (see binary tables below)
12
NOT USED
13
STOP
MOTOR
Remote motor stop.
When active, the screwdriver stops running and remains disabled.
The message “STOP MOTOR ON” appears on the display.
This signal disables the screwdriver and is prioritized over any other
signal: START and REVERSE signals as well as the physical lever on
the screwdriver will be ignored when STOP MOTOR is active.
14
START
Remote motor start.
This pin serves the same function as the physical lever on the
screwdriver. Activating it initiates the screwdriver motor.
The signal must be maintained active for the motor to continue
running.
The motor will continue running until this signal is removed or until
the rundown completes according to the current program
parameters (for example, when reaching torque).
As soon as the rundown completes, the screwdriver motor stops and
this signal will be ignored until it is pulled down (for a
recommended minimum of 30ms).
15
REVERSE
Remote motor reverse start.
Содержание K-DUCER
Страница 1: ...KDU1 KDU1A Torque range 0 1 70 Nm OPERATOR MANUAL...
Страница 22: ...Vers 062721 22 Main Screen Program Mode navigation tree...
Страница 25: ...Vers 062721 25 Main Screen Sequence Mode navigation tree...
Страница 32: ...Vers 062721 32 PROGRAMS menu tree...
Страница 33: ...Vers 062721 33...
Страница 34: ...Vers 062721 34...
Страница 44: ...Vers 062721 44 SEQUENCE SETTINGS menu tree...
Страница 53: ...Vers 062721 53 USB menu tree...
Страница 59: ...Vers 062721 59...