15
Setup
15.1
Safety notes
Only specialist personnel with extensive knowledge in the areas of electrical engineering /
drive technology are allowed to commission the drive unit of servo amplifier and motor.
Deadly voltages can occur, up to 900V. Risk of electric shock! Check that
all live connection points are safe against accidental contact.
Never undo the electrical connections to the motor when it is live. Risk of
electric shock! The residual charge in the capacitors of the servo amplifier
can produce dangerous voltages up to 10 minutes after the mains supply
has been switched off.
Measure the DC-link voltage and wait until it has fallen below 40V. Even
when the motor is not rotating, control and power leads may be live.
The surface temperature of the motor can exceed 100°C in operation.
Danger of light burns! Check (measure) the temperature of the motor.
Wait until the motor has cooled down below 40°C before touching it.
The drive performing unplanned movements during commissioning
cannot be ruled out.
Make sure that, even if the drive starts to move unintentionally, no danger
can result for personnel or machinery.
The measures you must take in this regard for your task are based on the
risk assessment of the application.
English - 34
Servomotors VLM
Setup
01/2013
Kollmorgen
ENGLISH
Содержание VLM Series
Страница 8: ...Diese Seite wurde bewusst leer gelassen Deutsch 8 Servomotoren VLM 01 2013 Kollmorgen DEUTSCH...
Страница 65: ...This page has been deliberately left blank Servomotors VLM General 65 Kollmorgen 01 2013 Datos t cnicos...
Страница 77: ...36 2 EC Declaration of Conformity Servomotors VLM General 77 Kollmorgen 01 2013 Approvals...