12
Technical Description
12.1
General technical data
Ambient temperature
5...+40°C for site altitude up to 1000m amsl
(at rated values)
It is vital to consult our applications department for
ambient temperatures above 40°C and encapsulated
mounting of the motors.
Permissible humidity
95% rel. humidity, no condensation
(at rated values)
Power derating
1% / K in range 40°C...50°C up to 1000m amsl
(currents and torques)
for site altitude above 1000m amsl and 40°C
6%
up to 2000m amsl
17% up to 3000m amsl
30% up to 4000m amsl
55% up to 5000m amsl
No derating for site altitudes above 1000m amsl
with temperature reduction of 10K / 1000m
Ball-bearing life
³
20.000 operating hours
Technical data for every motor type can be found in chapter "Technical Data" from p. 66.
12.2
Standard features
12.2.1
Style
The basic style for the VLM motors is style IM B5 according to EN 60034-7.
12.2.2
Flange
Flange dimensions to NEMA standard (NEMA ICS 16 Metric, NEMA ICS 19 Inch),
fit h7/ j6
Accuracy:
Shaft extension concentricity: 0,05 mm
Concentricity of the flange: 0,1 mm
Runout tolerances : 0,1 mm
Maximally permissible flange temperature in continuous operation: 65°C
Servomotors VLM
English - 29
Kollmorgen
01/2013
Technical Description
ENGLISH
Содержание VLM Series
Страница 8: ...Diese Seite wurde bewusst leer gelassen Deutsch 8 Servomotoren VLM 01 2013 Kollmorgen DEUTSCH...
Страница 65: ...This page has been deliberately left blank Servomotors VLM General 65 Kollmorgen 01 2013 Datos t cnicos...
Страница 77: ...36 2 EC Declaration of Conformity Servomotors VLM General 77 Kollmorgen 01 2013 Approvals...