6.2 Ambient Conditions, Ventilation, and Mounting Position
Storage, Transport
Normal operation
Environmental class 3K3 according to IEC 61800-2
Surrounding tem-
perature in operation
Internal regen resistor used:
0 to +40 °C under rated conditions
+40 to +60 °C with current derating 3 % per Kelvin
Internal regen resistor not used:
0 to +50 °C under rated conditions
+50 to +60 °C with current derating 2 % per Kelvin
Humidity in operation
Relative humidity 5 to 85%, no condensation, IEC 61800-2 class
3K3
Site altitude
Up to 1000 m above mean sea level (AMSL): no restriction
1,000 to 2,000 m AMSL: power derating 1.5%/100 m
Maximum altitude: 2000 m AMSL
Pollution level
Pollution level 2 as per IEC 60664-1
Vibration
Class 3M1 according to IEC 61800-2
Shock
Class L according to IEC 61800-2
Drive protection
IP 20 according to IEC 60529
Drive EMC immunity
Increased immunity according to EN 61800-5-2
Mounting
Vertical position, in a cabinet with protection of at least IP 54
Ventilation
Built-in fan in all drive variants
The drive shuts down in case of excessively high temperature in
the control cabinet. Make sure sufficient forced ventilation is sup-
plied within the control cabinet.
6.3 Mechanical Data
AKD2G-Sxx-
Units
6V03S,
6V06S,
6V12S
7V03S,
7V06S,
7V12S
6V03D,
6V06D
7V03D,
7V06D
Weight (with X22 and X23)
kg
2.6
2.9
2.6
2.9
Width
mm
76
75
76
75
Height, without connectors
front/back
mm
220/235
255/272
220/235
255/272
Height, with connectors
mm
303
340
303
340
Depth, without connectors
mm
221
221
221
221
Depth, with connectors
mm
<235
<235
<235
<235
Dimension Drawing see section Mechanical Installation (
AKD2G-S Installation, Safety 1 | 6 Technical description and data
Kollmorgen | kdn.kollmorgen.com | Beta, December 2018
33