AKD2G-S Installation, Safety 1 | 8 Electrical Installation
8.14.6.5 Digital-Out 9, Relay contacts
Digital-Out 9 is programmable with the setup software (for more information refer to
WorkBench).
By default, the output function is defined as ready to operate output by action keyword.
Technical characteristics
Relay output, max. 30 VDC or 42 VAC, 1 A
Time to close: max. 10 ms
Time to open: max. 10 ms
110
Kollmorgen | kdn.kollmorgen.com | Beta, December 2018