5
1057616-W2-J
Note!
Should the supplies be reversed then
the mixing valve will not be able to control
temperature. This can be corrected by rotating
the thermostatic cartridge within the valve body,
refer to section:
‘Installation, Outlet Position/
Reversed Inlet Supplies’
.
All models can operate in any plane, and may
be inverted if necessary for pipework layout
convenience, provided hot and cold pipework
is connected to the appropriate inlets (hot - red,
cold - blue).
Inlet/Outlet Options:
inlets*
outlet*
215-t3 c
top,
bottom,
rear-fed
top
, bottom
215-t3 bc
side
top
, bottom
215-t3 dk
222-t3 dk
any
configuration
any
configuration
215-t3 oem
side
bottom,top
215-t3 zc
rear-fed
top
, bottom
*Products are supplied in the configuration shown