11
1057616-W2-J
Rada 215-t3 c
1.
The inlet elbows are positioned to accept
falling supplies. Should the installation require
rising or rear entry supplies then the elbows
will need rotating:
(a)
Loosen the elbow grubscrew using a
2.5 mm hexagonal key.
(b)
Pull the elbow away from the valve body
and refit in the desired position, re-tighten
the grubscrew.
Note!
Make sure that the ‘O’ seal is
correctly fitted.
2.
Loosen the backplate grubscrews using
a 2.5 mm hexagonal key and pull off the
backplate.
3.
For solid walls drill the holes for the backplate
with a 6 mm drill and insert the wall plugs. For
other types of wall structure alternative fixings
may be required (not supplied).
4.
For rear entry supplies:
drill the holes for the
supply pipes at 153 mm centres and recess the
wall to allow for the concealing plates, Ø32 mm
x 10 mm deep.
Note!
Depth must be sufficient to prevent the
concealing plates fouling on the plumbing
elbows.
5. For falling supplies:
Mark the pipe positions
on the ceiling and set the 33 mm centres from
the finished wall.
For rising supplies:
Mark the pipe positions
and set the 33 mm centres from the finished
wall.
33 mm
6.
Fit the supply pipework (
Hot - Left, Cold -
Right
).
7.
For 15 mm compression inlet or outlet
connections: fit the compression nuts and
olives to the pipework.
For ½” BSP union inlet or outlet connections:
fit the flat-faced inserts, press in firmly.
Ø32 mm x 10 mm depth for
Concealing Plates
Apply Silicone Sealant
Backplate
Concealing Plates
12 mm from
finished wall
surface
Hot
Cold
153 mm
10 mm minimum
between elbow
and finished wall
surface
Ø 32 mm
12 mm
Elbow