Wand maintance
Wand and nozzle maintanance
Note:
mineral deposits in the water will block the nozzle, so it should be cleaned regularly. The interval of
cleansing is depend on the water quality. Clean nozzle when its performance is decreasing.
Nozzle
Wand
UV range
Nozzle
□
When unseated and cover is open, press Wand Clean function on APP and wand extends.
□
Manual clean wand.
□
Remove the wand spray tip by inserting a small thin object into the hole on the underside of the wand,
dismantle nozzle.
□
Inspect nozzle. If there is mineral buildup in the nozzle, remove the minerals by soaking the nozzle in a
cleaning solution until the minerals are gone.
□
Remove any mineral deposits from the spray tip opening in the cleansing wand.
□
Replace the spray tip if needed.
□
Reinstall nozzle after cleaning or replace new nozzle. Ensure the nozzle is below the upper plane of wand.
If the wand is higher than the upper level of wand, the nozzle may be damaged or influences the retraction
of wand.
□
After the completion of cleaning, press Wand Clean function on APP and wand retracts.