34
1478624-W2-A
Alternative Installation procedure using the wallplate
a.
Loosely screw the backplate to the wallplate with the two backplate screws
provided.
b.
Place the wallplate and backplate assembly over the copper pipe.
c.
Mark the position of the wallplate and its fixing holes on the wall.
d.
Remove the screws and backplate from the wallplate.
e.
Drill the two backplate fixing holes, if necessary make a recess approximately
6mm deep to accept the wallplate. Plug the two fixing holes.
f.
Place the wallplate over the copper pipe and fix to the wall with the two wallplate
screws.
g.
Temporarily fit the two backplate screws to the wallplate. This will prevent the
holes from becoming blocked with plaster and grout.
h.
Finish the surface of the wall as required ensuring the pipework is protruding by
25mm ± 2mm.
i.
Remove the two backplate screws.
j.
Place the backplate against the finished wall surface and use the two backplate
screws supplied to fix the backplate to the wallplate.
k.
Follow steps
(e)
-
(i)
from previous section to complete the shower arm installation.
Backplate
Copper
Pipe
Screw
6mm Recess
Retaining Ring
Retaining Nut