Unvented Mains Pressure System:

The thermostatic mixer can be installed with an unvented, stored hot water system.

Pumped System:

The thermostatic mixer can be installed with an inlet pump (twin impeller). The pump 

must be installed in a suitable location and in accordance with its instructions.

Installation

General

1.

   Installation of the shower must be carried out in accordance with these instructions 

by qualified, competent personnel.

2.

   The plumbing installation must comply with all national or local water regulations 

and all relevant building regulations, or any particular regulation or practice 

specified by the local water supply company.

3.

   Make sure all pressures and temperatures comply with the requirements of the 

shower. See 

‘Specifications’

. For Type 2 Valves, refer to supply conditions given 

in the 

TMV2 Requirements Manual (

this is available to view or download from 

our website www.mirashowers.com)

.

4.

   Full bore/non restrictive servicing valves must be fitted in a readily accessible 

position adjacent to the shower to facilitate maintenance of the shower.

  DO NOT

 use a valve with a loose washer plate (jumper) as this can lead to a 

build up of static pressure.

5.

 

 DO  NOT

 apply excessive force to plumbing connections; always provide 

mechanical support when making plumbing connections. Any soldered joints 

should be made before connecting the shower.

6.

  Pipework dead-legs should be kept to a minimum.

7.

 

DO NOT 

install the shower unit in a position where access for maintenance is 

restricted.

8.

   The shower must be fitted to a waterproof, flat and even wall surface. The two 

screws and wall plugs supplied are suitable for most solid wall installations. Alternative 

fixing screws for panel structures are not supplied. Use both fixing points to secure 

the shower, be sure to use fixings appropriate for the chosen wall structure.

9.

  When pipework enters the product from the rear through a hole in the wall, 

provision must be made to prevent water ingress back into the wall structure.

10.

   Position the shower unit where the controls are at a convenient height for the 

user. Position the showerhead so that the water sprays in line with the bath or 

across the opening of a shower cubicle. The installation must not cause the 

shower hose to be kinked during normal use.

11.

  The water supplies to this product should be isolated if the product is not to be 

used for a long period of time. If the product or pipework is at risk of freezing 

during this period they should also be drained of water.

Содержание Mira Agile ERD+

Страница 1: ...Mira Agile S Mira Agile ERD Mira Agile Sense ERD Mira Agile Store EV Mira Agile EV These instructions must be left with the user Installation and User Guide For SPARES ADVICE or REPAIRS please call u...

Страница 2: ...as reached the end of its serviceable life please take it to a recognised facility such as your local civic amenity site for recycling Your local authority or retailer will be able to advise you of yo...

Страница 3: ...672 257 2 710 194 DE FR GB IT NL SE USA 8 167 215 8 517 282 Pack Contents 2 x Screws 2 x Wall Plugs 2 x Flow Reg 2 x Hex Key 1 x Grease Sachet 1 x Shower Unit Agile S Agile S Eco Agile EV 1 x Wallplat...

Страница 4: ...x Guarantee Card Documents 1 x Shower Unit 1 x Wallplate Pack 2 x Screws 2 x Wall Plugs 2 x Hex Key 1 x Grease Sachet 2 x Grubscrew 1 as a spare 1 x Component Pack 1 x First Fix Pipe Guide Agile ERD...

Страница 5: ...E OBSERVE THE FOLLOWING TO REDUCE THE RISK OF INJURY INSTALLING THE SHOWER 1 Installation of the shower must be carried out in accordance with these instructions by qualified competent personnel Read...

Страница 6: ...ce to the shower unit without supervision 10 Always check the water temperature is safe before entering the shower 11 DO NOT adjust the temperature control rapidly while using the shower 12 Use cautio...

Страница 7: ...he maximum hot water temperature is limited to 65 C Cold Water Range up to 25 C Minimum Recommended Differential between Hot Supply and Outlet Temperature 12 C Thermostatic Shut down For safety and co...

Страница 8: ...to a build up of static pressure 5 DO NOT apply excessive force to plumbing connections always provide mechanical support when making plumbing connections Any soldered joints should be made before con...

Страница 9: ...pressure for the appliance and must not be fitted For Fluid Category 5 double checkvalves are not suitable 12 The position of the shower and shower fittings must provide a minimum air gap of 25mm bet...

Страница 10: ...the boundaries listed step 6 below the wall plate may not conceal drilled holes The shower fittings should be positioned at a convenient height for all the family Position the fittings to spray acros...

Страница 11: ...onnection to the valve DO NOT use any other pipe sizes 4 Ensure you have enough pipework through the wall to allow it to be cut to the specified length when wall is finished refer to the instruction o...

Страница 12: ...O NOT drill through the pipe guide Mark these two Holes First Fix Pipe Guide b Make sure the holes drilled through the noggin are square and level to the mounting surface SIDE VIEW TOP VIEW 50 mm Min...

Страница 13: ...es may damage the seals in the mixer valve Note De burr the pipework if necessary IMPORTANT Use 15 mm copper pipe to valve Min 18 mm to Max 28 mm from finished wall surface Plasterboard 1 5 m m 1 5 m...

Страница 14: ...ugh them into the finished wall surface Drill through the 2x holes in the shroud 3 4 Pipe Shroud Drill holes here 6 mm Wall Plug Fit the wallplate over the pipes ensuring they do not push back into th...

Страница 15: ...revent the possibility of property water damage the screws MUST be tightened YOU MUST FULLY TIGHTEN the pipe retaining screws to clamp the pipes Failure to do so may result in water damage to your pro...

Страница 16: ...hexagonal wrench Tighten securely Retaining Screw Retaining Screw 11 12 Backplate Retaining Screw Orientation markers always on top DO NOT USE POWER TOOLS TO TIGHTEN THE RETAINING SCREW Grease the pip...

Страница 17: ...water supplies and check for leaks Refer to separate guide for instructions on how to fit the shower fittings Note The shower must be commissioned before first use see section Commissioning and Inform...

Страница 18: ...s very low to a combination boiler a 9 l min flow regulator may be required to improve the hot water performance Contact Mira Customer Service Note The 6 l min flow regulator may affect the performanc...

Страница 19: ...rty of the homeowner Note For Type 2 installations the maximum temperature is determined by application refer to the TMV2 Requirements Manual If you experience any difficulty with the operation of you...

Страница 20: ...approximately 1 C Warmer Cooler 3 5 4 Turn the shower off again Refit the control lever Red Stopper Handle Drive Ensuring correct orientation OFF at the top refit the stop assembly and the retaining...

Страница 21: ...use a single sequential control for on off and temperature control Allow a few seconds for any temperature adjustment to take effect Allow temperature to stabilise before making a new adjustment Alwa...

Страница 22: ...stop assembly and the retaining screw to the body 2 1 User Maintenance WARNING PLEASE OBSERVE THE FOLLOWING TO REDUCE THE RISK OF INJURY OR PRODUCT DAMAGE DO NOT allow children to clean or perform any...

Страница 23: ...Important The showerhead must be descaled regularly Keeping the shower spray clean and free from limescale will ensure that your shower continues to give the best performance In service Tests The prin...

Страница 24: ...Service Fluctuating or reduced flow rate Hose shower head or filter blocked Remove and clean Check hose and replace if necessary Check the filters for any blockage See User Maintenance The inlet press...

Страница 25: ...2 Wall Plate Assembly Agile S Agile S Eco Agile EV 1736 950 Cartridge Assembly 1736 986 Screw Pack A 1736 949 Control Assembly 1736 980 Backplate 1736 706 Outlet Nipple A A A 1736 990 Pipe Guide 1736...

Страница 26: ...36 962 Wall Plate Assembly Agile ERD Agile Sense ERD Agile Store EV 1736 950 Cartridge Assembly 1736 986 Screw Pack A 1736 949 Control Assembly 1736 980 Backplate A 1736 990 Pipe Guide 1736 984 Headnu...

Страница 27: ...27 1285246 W2 D Notes...

Страница 28: ...for loss of use of the product or consequential or indirect loss of any kind Damage or defects caused if the product is repaired or modified by persons not authorised by us or our appointed represent...

Отзывы: