Symptom
Cause
Recommended Action
Only hot or cold water
from the shower.
Water inlets are reversed
(hot supply to cold supply).
Installation error, supply pipework
requires rework.
The shower temperature is
either too hot or too cold.
No hot or cold water
reaching the shower unit.
Check there is an adequate supply of
hot water. See
‘Specifications’
.
Check the filters for any blockage refer
to section ‘User Maintenance’.
Installation conditions outside
operating parameters, refer to
sections:
‘Specification’
and
‘Commissioning’
.
If the temperature is too cold and
you have a combination type boiler
it may not be producing sufficiently
hot water at desired flow rate (refer
to
‘Specification’
). Make sure flow
regulator is fitted. For more information,
See
‘Information on Flow Regulators’
or contact
Customer Service
.
Fluctuating or reduced
flow rate.
Hose, shower head or filter
blocked.
Remove and clean. Check hose
and replace if necessary. Check the
filters for any blockage. See
‘User
Maintenance’
.
The inlet pressures are
insufficient or unbalanced.
See
‘Specifications’
.
Air lock or partial blockage
in the pipework.
Flush inlet pipes.
Flow regulator fitted
incorrectly.
See Fittings Installation and User
Guide.
Low flow causing
combination boiler to cycle.
Incorrect flow reg fitted, blocked
showerhead, hose or filters.
Water leaking from the
shower head.
Normal for a short period
after shut off.
See
‘Specifications’
.
The inlet pressures exceed
the requirements for the
shower unit.
See
‘Specifications’
.
Damage to the shower unit
cartridge.
Renew the cartridge.
Movement of valve on the
wall.
Pressure spike in water
system.
Tighten the retaining screw.
Fault Diagnosis
Only use genuine Kohler Mira replacement parts.
If you require a Mira trained service engineer or agent, please see
“Customer Service”
on
the back cover of this guide.