1. Flush the water supply pipes thoroughly to remove debris.

 Faucet is designed for tap water or potable water.

2. Do not apply excessive force to the product as doing so 

may cause damage.

3. Do not damage the surface of sensing window when

installing or cleaning the faucet.

4. When installing DC type faucets, pay special attention 

to the directions of battery electrodes. Tighten the battery 

cover to prevent its exposure to moisture.

5. When installing AC type faucets, strictly follow indicated 

instructions to perform electric connection. Do not turn on 

AC power supply before installation is completed. 

6. One AC power supply can power no more than two 

faucets at a time.

7. General power supply must be protected by proper fuse.

8. Do not put the faucet near strong ultraviolet or

electromagnetic field.

9. Cover the sensing window with black tape when 

repairing lavatory.

1

. 一定要先彻底冲洗供水管以清除管道中的杂

,

使用水源为自来水或可供饮用水。

2

.请勿将强力及冲击施于产品,以免造成故障,

引起漏水。

3

.安装、清洁龙头时,切勿损伤感应窗口表面,

以免造成故障。

4.

 

对于直流龙头, 安装时注意电池的正负极不

能装反,电池盒盖要拧紧,防止电池受潮。

5.

对于交流龙头,安装时务必按照说明书的要

求正确连接导线,龙头安装完毕后才可向电源盒

供电。

6.

一个交流电源盒最多可供两个感应龙头。

7.

交流电的总电源必须有合适熔断丝加以保护。

8.

请勿使产品感应窗口靠近强紫外线或电磁场。

9. 

修理面盆时,用黑色电工胶布粘住感应窗口。

10.

维修交流龙头时,必须断开交流电源并关闭

水源。

萝瑞入墙式单冷交流感应龙头(不带交流电源盒)
萝瑞入墙式单冷直流感应龙头

98452T-CP
98453T-CP

10.Turn off AC power supply and water supply before repairing 

faucet.

安装之前

NOTES:

上海科勒电子科技有限公司

中国上海浦东新区金滇路

18

E

 

邮编:

201206

BEFORE YOU BEGIN

注意事项

安装说明书

萝瑞

LOURE

Wallmount Sensor Faucet

1205259-2-A

1

Содержание LOURE 98452T-CP

Страница 1: ...When installing DC type faucets pay special attention to the directions of battery electrodes Tighten the battery cover to prevent its exposure to moisture 5 When installing AC type faucets strictly f...

Страница 2: ...rs Under Counter Lavatory K 2661T Forefront Vessel K 14800T Chalice Vessel NOTE To prevent water from splashing out users are recommended to use lavatories as recommended above OPERATION INSTRUCTIONS...

Страница 3: ...more than 2 0L s at 0 3MPa Timeout Setting 1 minute OperationTemperature 1 55 Water Temperature 0 5 71 Water Pressure 0 05 0 86MPa 41 2 54 31 75 226 66 5 72 54 Output DC3V 3V Input AC220V 220V ROUGH I...

Страница 4: ...owed to enter or reflected into the sensing window where no objects susceptible to reflection are placed in front of the sensor e g mirror polished stainless steel and other objects with mirrored surf...

Страница 5: ...Make faucet water pipe and wire through mounting bracket screw and secure spout to the mounting bracket make sure the spout forwarding to vessel 3 Insert the escutcheon 3 into the spout and secure it...

Страница 6: ...fix the control box on the wall by screws 8 keep the control box parallel to the wall 5 6 7 10 11 1 2 3 12 13 2 5 14 13 12 Outlet Inlet 12 13 14 15 16 10 9 11 Round Hole Hex Hole Take out the battery...

Страница 7: ...tomatic adjusting sensing distance about 2minutes The faucet will not work during this period U 7 5 6 1 5 6 17 U 2 2 Connect AC DC transformer How to Install the Drain 18 19 18 19 Screw off the drain...

Страница 8: ...Connect to electrical Source AC220V DC Connect to Faucet Connect to electrical Source Connect to Faucet Note Not allowed connect AC 220V electrical source to DC wire connector of AC DC transformer Fa...

Страница 9: ...ove 2 After wire layout finished check and repair if needed Then connect AC connector of AC DC transformer to electrical source from the control box and DC connector of AC DC transformer to faucet Tur...

Страница 10: ...read check valve G1 2 MIN 50mm 10 1205259 2 A Wall Wall Tee hot Outlet Tee cold G1 2 Please user prepare external thread check valve G1 2 G1 2 Please user prepare external thread check valve G1 2 Tee...

Страница 11: ...faucet is in the period of adjusting sensing distance after power on for 2 minutes During these 2 minutes please do not put objects in the sensing range 2 The indicator flashes every 2 seconds As for...

Страница 12: ...27 3 Remove and clean the filters 25 then reinstall them 3 15 3 Intelligent Stopping Flowing Water will flow out when object are putted into the sensing range If the objects hold still for 15 seconds...

Страница 13: ...r 2 minutes Open the connector assemblies Check the batteries Check the power supply and the conncetion Remove the object Clean the sensing window Check the connector 2 1 No water flow Indicator not f...

Страница 14: ...5611 SP CP Drain 2 5mm Hex Wrench 2 5mm 1 5mm Hex Wrench 1 5mm 16306T NA AC DC Transformer Only for 98452T CP 98452T CP 1068120 SP Connection Wire Kit Battery Alkaline Largess 2013 2013 18 E 201206 14...