background image

Bolt

 Mark symbol

Hole(two sides)

305mm

3/8

10mm

Fig.#9

 D.

Drill two holes and insert plastic inserts and T-bolts (Purchased by customer)

Fig.#10

2.

3.

 

Confirm the toilet drain hole center and  mark down the centerline  on Front, back, left and 

right outside of toilet.
Make sure the toilet  side mark symbol is align to  the drain hole centerline on the finished

floor.Mark down the left and right holes.

C. 1.

 Confirm the drain hole center and mark down the“+”centerline perpendicular to the finished 

 wall.  

Fig.#8

Unit: mm

250

10

330

10

250

10

200

5

85

5

305

150

10

150

10

100

10

Kohler Co.

7

1373184-IN01-A

Содержание K-5401IN-0

Страница 1: ...T K 5401IN 0 Kohler China Investment Co Ltd No 158 Jiangchangsan Road Jing An District Shanghai PRC Post Code 200436 Manufacturer Shanghai Kohler Electronics Ltd No 1955 Fengxiang Road Baoshan Area Shanghai PRC Post Code 200444 1373184 IN01 A ...

Страница 2: ...et Fully turn on the tee valve Firstly flush three times and test Fill the bucket with water into the bucket for 10 seconds The mininum water volume is advised to be above 5 7L Pre arrange enough space for toilet installation Make sure it will not affect the opening and closing of the door When install the product in the room a stop valve shall be installed in a close proximity For emergency circu...

Страница 3: ...e t y t i c a p a c y l p p u s r e t a w d e t a c i d e d e s u t s u m n o i t n e t t A flush three times and test The minimum dynamic pressure for the testing device is advised to be above 0 046Mpa 6 7 psi Observe all local plumbing and building codes Carefully inspect the new toilet for damage Water and electrical supplies may be wall mounted There is a wiring schematic on the inside of the ...

Страница 4: ...ght of product Inlet water temp Operation Environment NOTE See Homeowner s Guide for detailed specifications of the bidet seat Fig 3 Kohler reserves the right to change marked dimensions without prior notice Remote control Unit mm 160 Finished Wall 438 900 533 100 150 250 Water Outlet Finished Floor 330 58 670 Tee valve G1 2 Need customer to purchase Bidet inlet hose G3 4 G1 2 Toilet inlet hose Te...

Страница 5: ...urn it off Press Warm Wind button to start the warm wind function Press the button to enter Rear Wash mode Light sensing area Press the button to enter Front Wash mode Press it again to turn it off Press the button to turn off the night light function long tone hint Press the button to turn off the power long tone hint Press it again to turn it off Press it again to turn on short tone hint PREPARA...

Страница 6: ...ted on the wall a GFCI or ELCB protected and water proof receptacle is required Fig 7 A INSTALLATION To Remove Existing Toilet Turn off the water supply Flush the toilet and use a sponge to remove the remaining water from the tank and bowl Disconnect the supply shut off valve if present and remove the old tank and bowl B Place an 800mmX800mm cushion on the floor take out the toilet from the carton...

Страница 7: ...down the centerline on Front back left and right outside of toilet Make sure the toilet side mark symbol is align to the drain hole centerline on the finished floor Mark down the left and right holes C 1 Confirm the drain hole center and mark down the centerline perpendicular to the finished wall Fig 8 Unit mm 250 10 330 10 250 10 200 5 85 5 305 150 10 150 10 100 10 Kohler Co 7 1373184 IN01 A ...

Страница 8: ...lectrical supply connect only to a a Class A Ground Fault Circuit Interrupter GFCI or Earth eakage Circuit Breaker ELCB NOTE This product is designed for installation with the electrical supply attached to the wall Both types are illustrated Refer to the dimensional information for your chosen installation Follow the dimensional information exactly when installing the hardwire electrical supply Si...

Страница 9: ...en the trap way will not be properly aligned Make all adjustments gently reference the toilet side mark symbol and the drain hole centerline on the finished floor until the trapway is properly seated Use nut and washer to fasten the bolts and fix up the toilet CAUTION Risk of product damage Do not move the toilet after the trap way is properly seated to avoid the wax seal invalidated Change the wa...

Страница 10: ...e B NOTE Please do not reuse the old hose K Connect the Water IMPORTANT The supplied hoses must be used for this installation Bidet inlet Valve B G1 2 Back view Toilet hose Toilet inlet Valve A G3 4 supply stop 250 10 330 10 100 10 150 10 Close by rotating the handle clockwise and open counterclockwise Handle of angle valve Tee valve Decorative cover Connect to grey water G3 4 Connect to tap water...

Страница 11: ...s down left button for about 2 seconds then press down right button for about 3 seconds and again press down left button for about 6 seconds to complete water flushing M Caulk along the toilet bottom except for the side plates Finish installation by fixing the side plates Side plate two sides Fig 17 Fig 18 Kohler Co 11 1373184 IN01 A ...

Страница 12: ...le Choose a mounting location for the remote holder that is easily accessible while sitting on the seat Drill two holes with depth larger than 45mm on the wall by drill with a diameter of 6mm in accordance with the position of screw holes on the remote control holder Install the expansion tube into the holes Peel off the release paper of the double sided tape at the back of holder Expansion pipe E...

Страница 13: ...ing sound of the motor and bicker When the lighting stops flickering the self check is completed When it is used for the first time product will be in default stage Front Water temp mid Pressure mid Position level 3 Rear Water temp mid Pressure mid Position level 3 Spiral Water temp mid Pressure mid Pressure mid Seat temp mid Wind temp mid Night light On Energy saving mode On Function of auto cove...

Страница 14: ...h In that case adjust the hoses G Flush again after this flushing in progress seated The wash mode when people are not Dryer fan stops in the process of may work even A Water failure B Tee valve for water supply is closed or not opened completely C Product is at standby mode D Not yet seated or current sitting posture unable to be sensed by the seat E Filter screen is blocked F Water pressure is i...

Страница 15: ... toilet body Check the section of Communication between remote controller and this machine and connect the toilet and the remote controller Touch the screen of remote controller Sit near to the toilet or be seated Press Wake up key of remote controller A Replace by new battery B Reinstall properly C A The seat is covered by foreign matters or the seat is wet B The toilet cover is interfered by peo...

Страница 16: ...le installing the toilet Thermalexpansion of hard setting material cement mortar will damage or crash the feet of toilet Kohler will not be responsible for any damage because of using hard setting material cement mortar for toilet installation WARNING Risk of product damage Do not throw into the toilet what that will cause the toilet to block such as newspapers and sanitary towel Do not bump the v...

Отзывы: