Governor System
66
62 690 05 Rev. E
KohlerEngines.com
FIELD INSTALLED UPDATED DESIGN GCU Blink
Code Tests
A
B
A
Green LED Light
B
Yellow LED Light
Speed control issues can also be diagnosed utilizing
on-board Blink Code diagnostic lights equipped in GCU.
These GCUs store blink codes/trouble codes, that can
be quickly diagnosed using blink code charts.
FIELD INSTALLED UPDATED DESIGN GCU Blink Codes for Software Stored Codes - Activated when key
is turned to ON position.
Failure Condition
Possible Causes
Response
Response
Time
LED Diagnostics
Yellow LED Green LED
Speed Error
BLINKS
ON
Watchdog Interrupt RFI interference
Ground to kill,
close throttle plate
BLINKS
BLINKS
Overtemp
Software bug
Lightning
Overspeed (Over
4500 RPM for 0.5
seconds sustained)
External noise on ECU input
Ground to kill,
close throttle plate
1 second
delay
ON
ON
Frozen throttle plate
DLA failure
Mechanical bindage
Excessive Battery
Voltage (> 18v for
0.5 seconds)
Overcharging electrical system
>18 volts
Ground to kill,
close throttle plate
0.5
seconds
OFF
ON