Specifications
Standards and Approvals
The KOHLER Digital Valve complies with all relevant directives for CE marking. The KOHLER Digital Valve is a type 1
electronic, independently mounted control for surface mounting. The KOHLER Digital Valve is a thermostatic water
mixing valve.
General
Pollution Degree
2
Rated Impulse Voltage
2.5 kV
Connections
22 mm brass (inlet), 15 mm plastic (outlets)
Suitability for Drinking Water Applications
Not suitable
Solenoid Type
Pilot operated
Water Connection Type
Permanent
Pressures
Thermostatic Standard
TMV 2 - HP (BS EN 1111 Type 2)
Maximum Static Pressure
1000 kPa (10 bar)
Maximum Maintained Pressure
500 kPa (5 bar)
Minimum Maintained Pressure
100 kPa (1 bar)
Supply Pressure Differential
Nominally equal
Temperatures
Maximum Temperature (setting range)
95°F - 118°F (35°C - 48°C) (Factory Preset 113°F (45°C))
Minimum Temperature
Thermostatic control down to 59°F (15°C)
Full Cold also selectable
Hot Water Range - Supply
131°F - 149°F (55°C - 65°C)
Cold Water Range - Supply
34°F - 68°F (1°C - 20°C)
Temperature Stability at Valve Outlet
± 1.8°F (± 1°C) at recommended supply conditions
Ambient Temperature
34°F - 122°F (1°C - 50°C)
Maximum Relative Humidity
95% noncondensing at 86°F (30°C)
NOTE: Valve operating outside of the manufactures recommended conditions of use cannot be guaranteed to operate as
TMV2 Type 2 valves.
Kohler Co.
7
1430528-W2-
A