5. Make the Connections
O-Rings
Retention Clips
Filters
15 mm Plastic Pushfit Connectors
(Outlet only)
22 mm Brass Connectors
(Inlet Only)
CAUTION: Risk of product damage. Do not apply excessive heat near the valve or apply flux or acids directly onto
the valve. This valve contains plastic and rubber components that will melt if heat is directly applied.
NOTE: If any outlets are not used, they must be capped or isolated using appropriate fittings.
NOTE: Do not use ammoniac flux types for soldering joints as these can cause corrosion.
NOTE: Do not use any type of jointing paste or compound on any pipework or fittings supplying the digital shower
valve. These can build up within the product and reduce the performance or cause early failure.
4-Outlet Valve
6-Outlet Valve
Zone 1
Outlet 1 and 2
Outlet 1, 2 and 3
Zone 2
Outlet 3 and 4
Outlet 4, 5 and 6
NOTE: Connectors are designed for push fit fittings and do not need to be removed to make the connection. Inlet
connectors are brass and can be soldered if desired. To solder inlet connectors please follow these steps:
Unthread the screws securing the cover to the valve. Remove the cover and set aside.
Lift and remove the retention clips.
Remove the inlet connectors.
Remove the O-rings.
Use needlenose pliers to remove the debris filters from the hot and cold valves.
Kohler Co.
17
1430528-W2-
A