TP-6069 6/03
20
Section 6 Electrical System
Amps
Max.
Voltage
Number
of Poles
Model(s)
20
250
1
4EFOZ
20
600
3
8.5/11.5EFOZ, 14EOZ
22
250
2
4EFOZ, 5EOZ
25
250
2
5EOZ
250
1
6.5EFOZ
30
250
2
6.5EFOZ
30
600
3
11.5/17.5/20EFOZ,
14/20/24EOZ—3 phase
33
250
2
8EOZ
35
250
1
4EFOZ
35
250
2
8EOZ
250
1
5EOZ
40
600
3
11.5EFOZ,
14/20/24EOZ—3 phase
42
250
1
9EFOZ
42
250
2
9EFOZ, 8/10EOZ
240
1
11/13EFOZ
240
2
11/11.5/17.5EFOZ
50
250
2
9EFOZ, 10EOZ
480
3
20/23/27EFOZ,
20/28/32EOZ—3 phase
55
250
1
5EOZ
240
1
13EFOZ
240
2
11/13EFOZ, 13/14EOZ
60
250
1
6.5EFOZ
600
3
17.5/20EFOZ,
20/24/28/32EOZ—3 phase
240
1
16EFOZ
70
240
2
13/20EFOZ, 15.5EOZ
70
250
1
6.5EFOZ, 8EOZ
600
3
20/24EOZ—3 phase
1
16/19EFOZ
80
240
2
16EFOZ, 20EOZ—1 phase,
20/24EOZ—3 phase
80
250
1
8EOZ
480
3
23EFOZ—3 phase
85
250
1
9EFOZ, 10EOZ
1
19EFOZ
90
240
2
19EFOZ—1 phase
20/23EOZ
480
3
27EFOZ—3 phase
240
2
23EOZ
100
480
3
23/27EFOZ,
28/32EOZ—3 phase
125
600
2
23/27EFOZ, 28EOZ—
1 phase, 27EFOZ—3 phase
125
600
3
23/27EFOZ,
28/32EOZ—3 phase
150
600
2
28/32EOZ—1 phase,
32EOZ— 3 phase
175
600
2
32EOZ—1 phase
Figure 6-2
AC Circuit Breaker Ratings (4--27EFOZ
and 5--32EOZ Models), Listed By Amps
Amps
Max.
Voltage
Number
of Poles
Type
Model(s)
60
600
3
UL/IEC
33EFOZ, 40EOZ
70
600
3
UL/IEC
40EFOZ, 40EOZ
80
480
3
UL/IEC
40EFOZ, 50EOZ
100
480
3
UL/IEC
55EFOZ, 50/65EOZ
100--125
600
3
IEC
33/55EFOZ,
40/65EOZ
100--125
600
3
IEC
70EFOZ, 80EOZ
125
600
3
UL
33/55EFOZ,
40/65EOZ
125
600
3
UL
70EFOZ, 80EOZ
128--160
600
3
IEC
33/40EFOZ,
40/50EOZ
128--160
600
3
IEC
70/80EFOZ,
80/99EOZ
150
600
3
UL
33/40EFOZ,
40/50EOZ
150
600
3
UL
70/80EFOZ,
80/99EOZ
160--400
600
3
UL
70/80/100EFOZ,
80/99/125/150EOZ
160--400
600
3
IEC
70/80/100/125EFOZ,
80/99/125/150EOZ
200
600
3
UL
40/55EFOZ,
50/65EOZ
200
600
3
UL
100EFOZ,
99/125EOZ
200--250
600
3
IEC
40/55EFOZ,
50/65EOZ
200--250
600
3
IEC
70/100/125EFOZ,
80/125/150EOZ
240--600
600
3
UL
125EFOZ,
125/150EOZ
250
600
3
UL
55EFOZ, 65EOZ
250
600
3
UL
70/125EFOZ,
80/125/150EOZ
250--630
600
3
IEC
125EFOZ,
125/150EOZ
Figure 6-3
AC Circuit Breaker Ratings (33--150 kW
Models), Listed By Amps
Accidental starting.
Can cause severe injury or death.
Disconnect the battery cables before
working
on
the
generator
set.
Remove the negative (--) lead first
when
disconnecting
the
battery.
Reconnect the negative (--) lead last
when reconnecting the battery.
WARNING
Содержание 100EFOZ
Страница 2: ......
Страница 4: ......
Страница 10: ...TP 6069 6 03 VI Safety Precautions and Instructions Notes ...
Страница 12: ...TP 6069 6 03 2 Section 1 Introduction Notes ...
Страница 14: ...TP 6069 6 03 4 Section 2 Location and Mounting Notes ...
Страница 20: ...TP 6069 6 03 10 Section 3 Cooling System Notes ...
Страница 26: ...TP 6069 6 03 16 Section 4 Exhaust System Notes ...
Страница 37: ...TP 6069 6 03 27 Section 6 Electrical System Figure 6 10 Remote Controller and Harness Options 33 150 kW Models ...
Страница 38: ...TP 6069 6 03 28 Section 6 Electrical System Notes ...
Страница 41: ...TP 6069 6 03 31 Section 7 Installation Drawings ADV 6652B B Figure 7 3 Remote Options 3 5EFOZ 4EOZ ...
Страница 84: ...TP 6069 6 03 74 Section 8 Reconnection Adjustments Notes ...
Страница 89: ......