HANDLING PROCEDURES AND PRECAUTIONS

Always observe the following items.
1. When using this product in pneumatic systems, always use

genuine KOGANEI parts or compatible parts (recommended parts).
When conducting maintenance and repairs, always use genuine
KOGANEI parts or compatible parts (recommended parts). Always
observe the required procedures.

2. Do not attempt inappropriate disassembly or assembly of the

product relating to basic configurations, or its performance or
functions. 
KOGANEI cannot be responsible if these items are not properly
observed.

OTHER

Installation

Precautions on Use

1. Before inspections, cleaning, or maintenance, be sure to switch off

power supply.

2. If the supply air to the Blow Type unit is suspended for some time, a

red indicator could turn on.

3. If the tube metal section of the Blow Type unit is connected to a

ground, the unit will automatically be powered down.

4. In case the unit turns faulty, it will have to be adjusted and repaired by

specialized personnel. Contact Koganei for such a service.

5. To replace the discharging needle of the Blow Type unit, a dedicated tool

has to be used. The dedicated tool (

DTRY-ELB21

) is used in combination

with a torque-screwdriver that accepts the bit-socket illustrated below.
The dedicated tool is designed to prevent the discharging needle
and screws of the main unit from being broken under excessive
force. Try to limit the tightening torque to 19.6 N

cm {2 kgf

cm} or

less. If the discharging needle or the main unit is damaged because
the discharging needle was replaced without using the dedicated tool,
it will not be covered under our warranty.

6. The service life of the discharging needle varies depending on

the environmental conditions where it is used. A poor operating
environment (e.g., very humid conditions) or failure to clean the pin
will lead to degraded performance of the discharging needle. Hence,
periodic maintenance is required.

7. Take care to wire correctly. When the + side and the –side of the

power supply wiring are reverse-connected to the main unit of the
ionizer, a failure will occur. 

8. When the power to the main unit of the ionizer is turned on immedi-

ately after being turned off, an abnormal output is produced. When
performing such an operation, be sure to allow at least 1 second or
longer after turning off.

ATTENTION

When considering the possibility of using this product in situations
or environments not specifically noted in the Catalog or Instruction
Manual, or in applications where safety is an important requirement,
such as in an airplane facility, combustion equipment, leisure
equipment, safety equipment and other places where human life or
assets may be greatly affected, take adequate safety precautions
such as applications with enough margins or fail-safe measures for
ratings and performance. Please consult KOGANEI with any
questions.

Always check the catalog and other reference materials for product
wiring and piping.

When handling the product, wear protective gloves, safety glasses,
safety boots, etc., to ensure safety.

When the product can no longer be used, or is no longer necessary,
dispose of it appropriately as industrial waste.

Do not use the Ionizer for any other purpose than the static
electricity removal.

1. For installation of the unit, pay attention to the contamination by oil or

water, high temperatures or high humidity. Especially, avoid a place
subject to dew condensation.

2. Install the ionizer in a place where ions can be sprayed on the charged

object, when the charged object is far from the other objects or is
suspended in the air. 

Reason: Even if ions are sprayed on the charged object when it is near

other objects or in contact with them, no electrostatic removal can be
made.

3. If the ionizer is not grounded properly, static electricity removal level

will be reduced. 

4. When mounting the fan, turbo-flow fan or wide-flow fan type ionizers,

do not thread mounting screws in 5mm or deeper; otherwise the
mounting screws may touch the inner circuit board.

5. When installing the fan, turbo-flow fan or wide-flow fan type ionizers,

ensure sufficient space so as not to block the suction opening, allow-
ing for the use of the airflow rate adjusting plate.

6.35

9

22

φ

4.5

Torque-screwdriver is sold separately.

Shape of the bit-socket

Содержание DTRY-ELB01

Страница 1: ...Catalog No BKC0010 DIN EN ISO 9001 JIS Z 9901 Certificate 09100 5919 Anlagentechnik GmbH ISO 14001 JIS Q 14001 Certificate No 09 104 8118 œœ TUV Rheinland Berlin Brandenburg i i t or ...

Страница 2: ...n of electrical noise due to low voltage output EMI locator reacts at 1mm position from the tip of a discharging needle Alarm output when abnormality occurs in high voltage section where generating ion Ensures prevention of producing defective products caused by faulty removal of static electricity Controller is available The controller includes an in line filter PLF100 and a regulator The former ...

Страница 3: ...plications Possible to remove static electricity on 1005 class electronic parts DTRY NZR04 100mm DTRY NZR05 200mm DTRY NZR06 300mm DTRY NZR07 400mm DTRY NZR08 500mm Nozzle with a conductive tube 500mm DTRY NZR03 Nozzle with a flexible tube DTRY NZR04 08 Nozzle with a stainless steel tube 120mm DTRY NZR02 Standard nozzle DTRY NZR01 取 Caution Please always read the Safety Precautions on p 5 before u...

Страница 4: ...t you can make fine adjustment of the direction of the airflow By using the flow direction adjusting plate at the fan outlet you can make fine adjustments of the horizontal direction airflow Turbo flow fan type Application examples Static electricity removal for circuit boards etc You can make static electricity removal for relatively wide objects Static electricity removal for packaging films etc...

Страница 5: ...ricity Removing Characteristics Static electricity removal Time sec Supply Air Pressure MPa Main Unit DTRY ELB01 Nozzle DTRY NZR02 Static electricity removal characteristics obtained when Nozzle with Stainless Steel Pipe is used 0 0 2 0 4 0 6 0 8 1 0 1 2 0 0 05 0 1 0 15 0 2 0 25 0 3 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 4 5 5 0 0 0 05 0 1 0 15 0 2 0 25 0 3 0 1 2 3 4 5 6 7 8 0 0 05 0 1 0 15 0 0 2 0 4 0...

Страница 6: ...k of the area of machine operation Careless supply of air or electricity could possibly result in electric shocks or in injury caused by contact with moving parts Do not touch the discharging needles the terminals and the miscellaneous switches etc while the device is plugged in There is the possibility of electric shock and abnormal operation Do not allow the product to be thrown into fire The pr...

Страница 7: ...e main unit of the ionizer a failure will occur 8 When the power to the main unit of the ionizer is turned on immedi ately after being turned off an abnormal output is produced When performing such an operation be sure to allow at least 1 second or longer after turning off ATTENTION When considering the possibility of using this product in situations or environments not specifically noted in the C...

Страница 8: ...10 Miniaturized AC high voltage high frequency type 300 with 12 VDC power supply 150 with 24 VDC power supply Approx 2 POWER LED green on the top of the main unit turns on while the power is supplied ALARM LED red on the top of the main unit turns on when abnormality occurs Provides an abnormal contact signal and alarm signal in the case of abnormality in high voltage section ALARM LED on the top ...

Страница 9: ...11 100 mm opening type 137 204 L 90 W 46 H 762 0 22 DTRY ELW12 200 mm opening type 154 304 L 90 W 46 H 1039 0 7 Wide flow fan type ionizer Item Model Power supply Operating high voltage power supply Consumption current mA Output voltage kV Indicator lamp Power safety circuit Outer dimensions mm Mass g Ion balance V Ozone generation amount ppm m3 min Fan capacity Operating environmental temperature...

Страница 10: ...be manufactured on order Note Bit at the tip part alone will be available for purchase DTRY ELB21 Shape of the bit socket Controller For Blow Type DTRY ELB01 02 DTRY ELC11 2 head type DTRY ELB02 The main unit cannot be operated alone Always use it with a nozzle Caution The main unit cannot be operated alone Always use it with a nozzle Caution Dedicated for blow type DTRY ELB01 02 Caution Flexible ...

Страница 11: ...ter for the turbo flow fan type and the wide flow fan type DTRY ELC03 AC adapter for the turbo flow fan type and the wide flow fan type DTRY ELC03 Optional bracket for the turbo flow fan type Rating Input AC100V to AC240V 50 60 Hz 40VA Output DC24V 750mA Flow rate adjusting plate Flow direction adjusting bracket for the wide flow fan type DTRY NZB11 100 mm opening type DTRY NZB12 200 mm opening ty...

Страница 12: ...IS C 3306 Power and signal connector molex 5557 04R Dimensions Unit mm BLOW TYPE MADE IN JAPAN DTRY ELB02 KOGANEI 5569 04A1 molex 12 68 12 92 6 80 6 62 11 40 11 14 2 14 2 32 15 48 33 18 15 32 15 54 39 5 10 A 2000 A 67 5 For power and signal connection TVS6 01 Throttle valve Ground terminal Nut M3 Power and signal cable VCTF 0 3mm 2 4 wires JIS C 3306 Power and signal connector molex 5557 04R Disch...

Страница 13: ...01M Fitting 538 500 φ6 31 Tube holder DTRY NZR31 BLOW TYPE Nozzles Standard nozzle DTRY NZR01 Conductive tube DTRY NZR03 Stainless steel pipe DTRY NZR02 Flexible pipe DTRY NZR Model DTRY NZR04 DTRY NZR05 DTRY NZR06 DTRY NZR07 DTRY NZR08 A 100 200 300 400 500 L 127 227 327 427 527 Mass g 32 37 42 47 52 M3 0 5 two 10 mm long bolts 2 peices included with the main unit φ22 18 9 25 5 φ6 5 30 5 16 5 φ15...

Страница 14: ...voltage Connector pin location and lead wire colors Section A A POWER SIGNAL H V FAN ALARM POWER DTRY ELF01 KOGANEI MADE IN JAPAN OUTPUT INPUT Signal output 5557 04N1 molex Power LED Green ON at supplying power FAN L H Fan capacity selector switch For power and signal connection Power and signal connector molex 5557 04R Power and signal cable VCTF 0 3 mm 2 4 wires JIS C 3306 Power and signal cable...

Страница 15: ...hite Abnormal output 2 black Output GND 3 red Input power DC 24V 4 green Power GND Pin location of molex 5557 04R female Power and signal cable Accessory Input power DC 24V Connector pin location and lead wire colors View from A A Flow direction adjusting plate 4 pcs Note Notes After mounting the turbo flow fan type by using the optional bracket DTRY ELQO1 the flow direction adjusting plate allows...

Страница 16: ...olts included φ9 100 70 16 9 10 71 22 6 18 11 32 24 2 φ4 2 2 pcs M4 0 7 10 mm length bolts included Dimensions Unit mm Optional Bracket for the fan type DTRY ELF31 2pcs M3 0 5 8 mm length bolts included 8 2 φ3 4 φ6 5 counter bore depth 3 3 φ9 60 45 11 9 8 71 22 6 18 11 32 24 2pcs M4 07 10mm length bolts included 2 φ4 2 ...

Страница 17: ... Pin location of molex 5557 04R female Power and signal cable Accessary Input power DC 24V Connector pin location and lead wire colors View from A Air flow rate selector switch Ground terminal Connector male molex 5569 04A1 Power indication LED Green Abnormality indication LED Red 15 1 4 φ4 5 mounting hole provided bracket 75 60 4 5 4 5 10 10 204 101 5 106 22 28 5 10 2000 Power and signal connecto...

Страница 18: ... 7 memo memo ...

Страница 19: ...和文カタログ No C2152 w ...

Страница 20: ... 3 21 Ohkubo Shinjuku ku Tokyo 169 0072 Japan Tel 03 5272 8781 Fax 03 5286 2763 LOS ANGELES REPRESENTATIVE OFFICE 3838 CARSON STREET SUITE 329 TORRANCE CA 90503 U S A Tel 310 792 0471 Fax 310 792 0462 SINGAPORE REPRESENTATIVE OFFICE Block 1001 Jalan Bukit Merah 06 08 Singapore 159455 Tel 2736461 Fax 2752551 URL http www koganei co jp E mail overseas koganei co jp ...

Отзывы: