K
w
●
Enables the removal of static electricity with pinpoint accuracy and where a high density is
present such as in textile fabrics.
Enables the removal of static electricity on a narrow part and large ion quantity per unit area.
●
Enables the removal of static electricity on moving sections such as in robotic applications.
Use of a flexible tube can be used on the moving section.
Various applications are possible by replacing the choice of nozzle.
●
Removal of static electricity in a pipe
(
φ
50 or less)
By inserting the tube inside a pipe enables
removal of static electricity.
●
Allows removal of static electricity on
precision parts with pinpoint accuracy,
such as in part feeder applications.
Possible to remove static electricity on 1005
class electronic parts.
DTRY-NZR04
(100mm)
DTRY-NZR05
(200mm)
DTRY-NZR06
(300mm)
DTRY-NZR07
(400mm)
DTRY-NZR08
(500mm)
Nozzle with a conductive tube.
(500mm)
DTRY-NZR03
Nozzle with a flexible tube.
DTRY-NZR04
〜
08
Nozzle with a stainless steel tube.
(120mm)
DTRY-NZR02
Standard nozzle
DTRY-NZR01
取
Caution
Please always read the “Safety Precautions” on p.5 before use.
50/60Hz
68kHz
0V
Voltage (+)
Voltage (-)
Voltage
Voltage
About -2kV
About +2kV
→Time
→Time
0V
Conventional method (commercial frequency)
High frequency method
+
+
+
+
−
−
−
−
+
+
+
+
+ − + − + − + − + − + − + − + − + − + − + − + −
AC
AC
●This enables to carry ions through a pipe or tube allowing
you to make pinpoint static electricity removal for distant
work pieces.
●Ions are generated uniformly and corona discharges
occur in a short time, allowing you to create a stable
high-ion-density environment.
●No high voltage wiring is required, thereby improving safety.