![Koganei DTRY-ELB01 Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/koganei/dtry-elb01/dtry-elb01_manual_1986815009.webp)
●
i
Item
Model
Power supply
Operating high-voltage power supply
Consumption current
mA
Output voltage
kV
Indicator lamp
Power safety circuit
Outer dimensions
mm
Mass
g
Ion balance
V
Ozone generation amount
ppm
m
3
/min
Fan capacity
Operating environmental temperature
℃
Accessories
Power supply
Abnormality
Max. flow rate
Adjusting
DC24V ±10%
Miniaturized AC high-voltage high-frequency type
About 2
When the supply power is turned on, POWER LED (green) on the front of the main unit lights up.
When the supply power is turned on, POWER LED (green) on the front of the main unit lights up.
When an abnormal high-voltage condition occurs, the warning signal is output (open collector output: DC24V, 10mA Max)
±20
0.05 (200 mm away from the front of the flow outlet)
Switching is performed using the flow rate selector switch.
0 to 40 for indoor
1 power and signal cable (2 m), 1 ground wire (2 m), and mounting bracket
DTRY-ELW11
(100 mm opening type)
137
204
(L)
×90
(W)
×46
(H)
762
0.22
DTRY-ELW12
(200 mm opening type)
154
304
(L)
×90
(W)
×46
(H)
1039
0.7
■
Wide-flow fan type ionizer
Item
Model
Power supply
Operating high-voltage power supply
Consumption current
mA
Output voltage
kV
Indicator lamp
Power safety circuit
Outer dimensions
mm
Mass
g
Ion balance
V
Ozone generation amount
ppm
m
3
/min
Fan capacity
Operating environmental temperature
℃
Accessories
Power supply
Abnormality
Max. flow rate
Adjusting
DC24V ±10%
Miniaturized AC high-voltage high-frequency type
207
About 2
When the supply power is turned on, POWER LED (green) on the front of the main unit lights up.
When an abnormal condition occurs, ALARM LED (red) on the front of the main unit lights up.
When an abnormal high-voltage condition occurs, the warning signal is output (open collector output: DC24V, 10mA Max)
102 (L) × 114 (W) × 37 (H)
455
±20
0.05 (200 mm away from the front of the flow outlet)
0.26
Adjustments are made using the flow rate adjusting plate.
0 to 40 for indoor
1 power and signal cable (2 m), 1 ground wire (2 m), and 1 flow rate adjusting plate
DTRY-ELT11
■
Turbo-flow fan type ionizer
Содержание DTRY-ELB01
Страница 18: ... 7 memo memo ...