K71000 Automatic PMCC Flash Point Analyzer 

Operation and Instruction Manual 

 
 

K71000-Manual

    

 

-

37-

 

 

Service 

 

Under  normal  operating  conditions  and  with 

routine  maintenance,  the  K71000  Automatic 
Pensky-Martens Flash Point Analyzer should not 
require  service.  Any  service  problem  can  be 
quickly  resolved  by  contacting  Koehler’s 
technical  service  department  either  by  letter, 
phone,  fax,  or  email.  In  order  to  assure  the 
fastest  possible  service,  please  provide  us  with 
the following information. 

 

Model Number:   

 

 

 

Serial Number:   

 

 

 

Date of Shipment:   

 

 

 

 

Storage 

 

This  laboratory  test  instrument  is  equipped 

with  electrical  components.  Storage  facilities 
should  be  consistent  with  an  indoor  laboratory 
environment.  This  testing  equipment  should  not 
be  subjected  to extremes of  temperature  and/or 
moisture.  This  equipment  was  shipped  from  the 
factory  in  a  corrugated  cardboard  container.  If 
long  term  storage  is  anticipated,  re-packing  the 
instrument  in  a  water-resistant  container  is 
recommended  to  ensure  equipment  safety  and 
longevity. 

 

Warranty 

 

Koehler  Instrument  Company  would  like  to 

thank you for your equipment purchase, which is 
protected by the following warranty. If within one 
(1)  year  from  the  date  of  receipt,  but  no  longer 
than  fifteen  (15)  months  from  the  date  of 
shipment,  Koehler  equipment  fails  to  perform 
properly  because  of  defects  in  materials  or 
workmanship,  Koehler  Instrument  Company, 
Inc.  will  repair  or,  at  its  sole  discretion,  replace 
the  equipment  without  charge  F.O.B.  its  plant, 
provided  the  equipment  has  been  properly 
installed,  operated,  and  maintained.  Koehler 
Instrument  Company  must be  advised  in  writing 
of the malfunction and authorize the return of the 
product  to the  factory.  The  sole  responsibility  of 
Koehler 

Instrument 

Company 

and 

the 

purchaser’s  exclusive  remedy  for  any  claim 
arising out of the purchase of any product is the 
repair or replacement of the product. In no event 
shall the cost of the purchaser’s remedy exceed 

the purchase price, nor shall Koehler Instrument 
Company  be  liable  for  any  special,  indirect, 
incidental, 

consequential, 

or 

exemplary 

damages. 

KOEHLER 

INSTRUMENT 

COMPANY,  INC.  DISCLAIMS  ALL  OTHER 
WARRANTIES,  EXPRESSED  OR  IMPLIED, 
INCLUDING  ANY  IMPLIED  WARRANTIES  OF 
FITNESS  FOR  A  PARTICULAR  PURPOSE. 
Please save the shipping carton in the event the 
equipment  needs  to  be  returned  to  the  factory 
for  warranty  repair.  If  the  carton  is  discarded,  it 
will  be  the  purchaser’s  responsibility  to  provide 
an appropriate shipping carton. 

 

10  Returned Goods Policy 

 

To  return  products  for  credit  or  replacement, 

please  contact  Koehler  Customer  Service  with 
your  purchase  order  number,  our  packing 
list/invoice  number,  the  item(s)  to  be  returned 
and the reason for the return. You will be issued 
a  Returned  Authorization  (RA)  number,  which 
must  be  prominently  displayed  on  the  shipping 
container  when  you  return  the  material  to  our 
plant.  Shipping  containers  without  an  RA 
number  prominently  displayed  with  will  be 
returned to the sender. Goods must be returned 
freight  prepaid.  Returns  will  be  subject  to  a 
restocking  charge,  the  application  of  which  will 
depend  upon  the  circumstances  necessitating 
the  return.  Some  returns  cannot  be  authorized, 
including  certain  products  purchased  from 
outside  vendors  for  the  convenience  of  the 
customer,  products  manufactured  on  special 
order,  products  shipped  from  the  factory  past 
ninety (90) days, and products which have been 
used or modified in such a way that they cannot 
be returned to stock for future sale. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание K71000

Страница 1: ...enue Bohemia New York 11716 1796 USA Toll Free 1 800 878 9070 US only Tel 1 631 589 3800 Fax 1 631 589 3815 http www koehlerinstrument com e mail info koehlerinstrument com Petroleum Testing Analysis...

Страница 2: ......

Страница 3: ...e statement is given cataloging the items that require separation from the equipment along with basic information on subsequent processing or recycling prior to disposal of the equipment http www dpa...

Страница 4: ...As a minimum the following substances preparations and components have to be removed from any separately collected WEEE Mercury containing components such as switches or backlighting lamps compact fl...

Страница 5: ...Safety Considerations 8 2 2 Unit Design 8 2 3 Contaminated Samples 9 2 4 Safe Quick Test Method 9 2 5 Fire Detection Suppression and Draft Shield Dome System 9 2 6 Equipment Modification and Replacem...

Страница 6: ...ility for losses arising from the negligent or improper use of our equipment nor for losses arising from the improper use or use other than intended Only deliberate action or gross negligence are grou...

Страница 7: ...ng needs Our products are backed by our staff of technically knowledgeable trained specialists who are experienced in both petroleum products testing and instrument service to better understand your r...

Страница 8: ...The scope of the method covers the analysis of products in the temperature range of 40 to 360 C but this automated apparatus extends the range from dew point 10 C to 400 C Internet Link to Summary AST...

Страница 9: ...ange Ambient to 405 C 761 F Flash Detection System Differential Thermocouple Ionization Detection Stirring Speed 0 to 300 RPM Heating Rate In accordance to ASTM D93 procedure A B C Quick Test 12 C min...

Страница 10: ...fety problems associated with the use of this equipment It is the responsibility of any user of this equipment to investigate research and establish appropriate safety and health practices and determi...

Страница 11: ...prescribed end point prior to running a quick test The set maximum run temperature is solely at the user s discretion We recommend this method of screening for ALL samples 2 5 Fire Detection Suppress...

Страница 12: ...emoved WARNING Electrical hazards exist inside the instrument case Lethal voltages and current are present Only factory authorized or otherwise qualified personnel may repair or service this instrumen...

Страница 13: ...r claim if requested When submitting a claim for shipping damage request that the carrier inspect the shipping container and equipment Do not return goods to Koehler without written authorization 3 3...

Страница 14: ...results outside the above mentioned criteria Ventilation A fume hood or exhaust system is required after performing a test Flammable vapors and or steam are generated during operation and must not be...

Страница 15: ...K71000 Automatic PMCC Flash Point Analyzer Operation and Instruction Manual K71000 Manual 13 4 Descriptions 4 1 Front of Instrument Figure 1 Instrument Descriptions_Front...

Страница 16: ...load factory software updates 4 Touch Screen Control Panel Main control point of instrument Please refer to section _ _ for full operational details 5 Leveling Feet To make adjustments to instrument l...

Страница 17: ...K71000 Automatic PMCC Flash Point Analyzer Operation and Instruction Manual K71000 Manual 15 4 2 Back of Instrument Figure 2 Instrument Descriptions_Back...

Страница 18: ...reen control panel 15 USB Port For connection to Keyboard or Mouse 16 RS232 Port For connection to external PC 17 Ethernet Port For connection to LIMS system 18 CPU Port For programming of internal CP...

Страница 19: ...etection thermocouple will automatically detect this and initiate re lighting of the flame 27 Pilot Flame The pilot flame ensures the test flame is lit prior to each test dip 28 Electric Ignitor Alter...

Страница 20: ...orities Key The fourth or factory level is designed for administrative purposes only and specifically allows for access to the factory settings menu From this screen the user can also Change User Pass...

Страница 21: ...t the which operations they want a particular user level to have access to The user can choose to turn on or off access to the Diagnostics Calibration and Custom Test Menus Click Save when complete Fi...

Страница 22: ...eset all global parameter settings back to the factory default Figure 7 Last Global Parameter Pop Up 5 Main Home Screen After clicking Yes or No to the Last Global Parameter pop up the user will be br...

Страница 23: ...d to a Laboratory LIMS system by clicking this button Print This function is only accessible when the user is in the results database screen Data can be sent to a printer by clicking this button Save...

Страница 24: ...dard Test Parameters Change Save minimum temperature in which the instrument lift can open safely and the temperature in which the cooling fan can be turned off Inst ID Setup Change Save Instrument ID...

Страница 25: ...Graph Tools The Graph screen features the following functions a Zoom In b Zoom Out c Pan XY Provides cursor that can be moved along graph and display data d Restore Resets X and Y Axis to default posi...

Страница 26: ...Dip Home Brings flame dip mechanism to home position b Find Lift Home Brings mechanical lift to Home Position also considered test position c Clean Position Brings mechanical lift to Clean Position h...

Страница 27: ...med Two Point Calibration RTD Correction Table User CRM Calibration Two Point Calibration as shown in Figure 14 below is performed using an external PT100 Simulator Box Available as an Additional Acce...

Страница 28: ...in which the user can input offset values for any of temperature values shown This table is particularly convenient for those with Certified Digital Contact Thermometers or Certified Liquid in Glass...

Страница 29: ...Material CRM samples using a Gas Ignition source 1 Input the certified flash point value from the CRM bottle label or test certificate into the first column titled CRM Flash Value 2 Perform a series...

Страница 30: ...erial CRM samples using the Electrical Ignition Source 1 Input the certified flash point value from the CRM bottle label or test certificate into the first column titled CRM Flash Value 2 Perform a se...

Страница 31: ...ric Pressure Correction Feature As pictured in Figure 18 below the user can Enter Atmospheric Pressure in Kilopascals kPa into the empty field The Measured Barometric Pressure is determined by the ana...

Страница 32: ...C value as pictured in Figure 19 below This method of calibration is useful when a material of known flash point is tested and the analyzer is displaying a value greater than the known value e g know...

Страница 33: ...RPM Heating Rate C min End Test Temperature EFP X C Fan Off Temperature C Pre Heat Limit Temperature C Pre Heat Ramp Rate C min Open Lift Temperature C Soak Temperature C Typically used only for Aspha...

Страница 34: ...parameter data will automatically be sent to the database Each test is listed in a single row with the information separated by column The user also has the option to delete or update the database lis...

Страница 35: ...and clicking on the Print button will cause a temporary Print Result Screen to appear followed by a Printer Options Menu See Figures 22 and 23 below Once the appropriate printer is selected click the...

Страница 36: ...n the user first enters this menu the display screen will be blank Clicking on the Monitor Traffic box will begin displaying the data communication At this time a screenshot can be taken of the curren...

Страница 37: ...for a Test Dip The Dip On Off Switch will activate or deactivate the dipping mechanism b Adjust Lift Mechanism Pressing the Up and Down Arrows will adjust the level at which the Lift Mechanism will b...

Страница 38: ...d See Figure 26 below The corrected flash point value is prominently displayed at the center of the screen Additionally the Type of Ignition used to perform the test is displayed as well as the Sensor...

Страница 39: ...authorize the return of the product to the factory The sole responsibility of Koehler Instrument Company and the purchaser s exclusive remedy for any claim arising out of the purchase of any product i...

Страница 40: ...K71000 Automatic PMCC Flash Point Analyzer Operation and Instruction Manual K71000 Manual 38 Notes...

Страница 41: ...K71000 Automatic PMCC Flash Point Analyzer Operation and Instruction Manual K71000 Manual 39 Notes...

Страница 42: ...K71000 Automatic PMCC Flash Point Analyzer Operation and Instruction Manual K71000 Manual 40 Notes...

Отзывы: