MDC-5000 Series
Chapter 4 Setup after installation
0092653004-00
4-23
4.4 Setup PRESET
4.4.1 Setup RAIN MIN and MAX mode
There are two modes of MAN and CFAR in anti-rain clutter mode.
Change method of MAN and CFAR.
Press the RAIN knob, or put a cursor on the indicator of MAN or CFAR upper right of the display and
press ENT key.
4.4.1.1 RAIN MIN (MAN and CFAR mode)
RAIN MIN is intended to adjust the preset minimum value of anti-rain clutter. This is a function even
when anti-rain clutter suppression knob is set at minimum.
This function has also effect to moderate the effect against turned angle of the knob and to make
adjustment easy. This setting can be applied to the entire range.
MAN mode
(1) Check MAN indication of RAIN mode from upper right of the display. If RAIN mode is CFAR,
change to MAN mode. If GAIN mode is AUTO, change to MAN mode. If SEA mode is AUTO,
change to MAN mode.
(2) Set RAIN at 0 by turning RAIN knob, set SEA at a moderate level by turning SEA knob, set GAIN
at 8 by turning GAIN knob and set BRILL at a maximum level by turning BRILL knob.
(3) Press MENU
key to display “Menu”.
Select [MAINTENANCE] => [PRESET] => [RAIN MIN] and highlight the last digit of the numerical
entry frame.
(4) Move the joystick up and down to change the value, and press ENT key when bondens and
seaway buoys have reduced small enough in size on the display.
Setting value is 0 to 4095: Initial setting is 0
CFAR mode
(1) Check CFAR indication of RAIN mode from upper right of the display. If RAIN mode is MAN,
change to CFAR mode. If SEA mode is AUTO, change to MAN mode.
(2) Set RAIN at 0 by turning RAIN knob, set SEA at a moderate level by turning SEA knob and set
BRILL at a maximum level by turning BRILL knob.
(3) Press MENU
key to display “Menu”.
Select [MAINTENANCE] => [PRESET] => [RAIN MIN] and highlight the last digit of the numerical
entry frame.
(4) Move the joystick up and down to change the value, and press ENT key when bondens and
seaway buoys have reduced small enough in size on the display.
Setting value is 0 to 4095: Initial setting is 0
Содержание MDC-5004
Страница 1: ......
Страница 2: ......
Страница 20: ...Chapter 3 installation method MDC 5000 Series 3 2 0092653004 00 RB808 RB809 Unit mm inch ...
Страница 88: ... This page intentionally left blank ...
Страница 114: ... This page intentionally left blank ...
Страница 130: ... This page intentionally left blank ...
Страница 150: ... This page intentionally left blank ...
Страница 151: ...0092653004 00 A 1 INTER CONNECTION DIAGRAM RB806 ...
Страница 152: ...A 2 0092653004 00 INTER CONNECTION DIAGRAM RB807 ...
Страница 153: ...0092653004 00 A 3 INTER CONNECTION DIAGRAM RB808 ...
Страница 154: ...A 4 0092653004 00 INTER CONNECTION DIAGRAM RB809 ...
Страница 155: ...0092653004 00 A 5 INTER CONNECTION DIAGRAM MRM 110 MRO 110 ...
Страница 156: ......