4.2.3 Set up Heading interfaces
4.2.3.1 Connection of KODEN GPS compass
Connect GPS compass to the J6 port.
Press MENU key to display
“Menu” and set as follows with the joystick.
(1) [MAINTENANCE] => [I/O] => [HDG] => [HDG] => [AUTO], and press ENT key.
Initialize GPS compass (DATA 1 or DATA 2 in KGC-222, DATA 2 in KGC-1 and J6 port of the radar are
optimally reset.)
(1) [MAINTENANCE] => [I/O] => [KGC SET] => [INITIAL] => [GO], and press ENT key.
Note: With this initialization, port connected to the radar of GPS compass is set at 38400 bps, 50 ms for
signal cycle, and HDT, GGA, VTG, DTM and ZDA for signal type.
Compensate angles of GPS compass
When mounting direction of GPS compass has been out of alignment, compensation of the
misalignment allows GPS compass to output HDT signals as follows.
(1) [MAINTENANCE] => [I/O] => [KGC SET] => [BRG CORR] => [0.0°], and then select the last digit of
entry frame for a numerical value and set with ENT key after pointing at the angle to be
compensated by moving the joystick up and down.
4.2.3.2 Connection of other device
In case of a gyro with analogue signal output such as step signal or synchronous signal (Refer to
“3.4.5
Connecting a Gyro converter unit or THD), insert a gyro converter unit between them, convert the
analogue signal into that of the NMEA signal of 38400bps, and then input the signal into the J3, J5 or
J6 port of this device.
When a THD (a gyro with output based on IEC 61162-2) or a GPS compass from another manufacturer
is connected (Refer to
“3.4.4 Connecting a Gyro converter unit or THD”), connect the output based on
IEC 61162 directly to the J3, J5 or J6 port of this radar. Setting can be performed with pressing MENU
key as follows:
(1) [MAINTENANCE] => [I/O] => [HDG] => [HDG] => [AUTO], and press ENT key.
Set values: AUTO, THS, HDT, HDG, HDM, VTG, RMC, RMA, MAN
Caution: In case of either HDG, HDM, VTG, RMC, RMA or Manual is selected, TT (ATA) function
and true trail will not always work properly.
Содержание MDC-5004
Страница 1: ......
Страница 2: ......
Страница 20: ...Chapter 3 installation method MDC 5000 Series 3 2 0092653004 00 RB808 RB809 Unit mm inch ...
Страница 88: ... This page intentionally left blank ...
Страница 114: ... This page intentionally left blank ...
Страница 130: ... This page intentionally left blank ...
Страница 150: ... This page intentionally left blank ...
Страница 151: ...0092653004 00 A 1 INTER CONNECTION DIAGRAM RB806 ...
Страница 152: ...A 2 0092653004 00 INTER CONNECTION DIAGRAM RB807 ...
Страница 153: ...0092653004 00 A 3 INTER CONNECTION DIAGRAM RB808 ...
Страница 154: ...A 4 0092653004 00 INTER CONNECTION DIAGRAM RB809 ...
Страница 155: ...0092653004 00 A 5 INTER CONNECTION DIAGRAM MRM 110 MRO 110 ...
Страница 156: ......