![Koden CVG-200 Скачать руководство пользователя страница 129](http://html1.mh-extra.com/html/koden/cvg-200/cvg-200_operation-manual_1984714129.webp)
Chapter 6
CVG-200
Using the Menu
6-52
0093132802-05
Heading
Scan area
Own ship
Range
60degree
6.4.5.7
DEPTH LIMIT ALARM
This alarm (audio) is activated when the depth value of own ship’s position becomes shallower than
the set value.
Setting range (depth): 0 to 999 m, fm or ft
Initial setting: 5 m, fm or ft
6.4.5.8
GROUNDING ALARM
This alarm (audio) is activated when the danger of running aground is detected. This function has
been achieved by regularly scanning the map data forward of own ship’s position. The execution
interval of the scanning is 2 seconds. The Figure below shows the range of scanning.
Detected dangerous items are as follows.
shallow water, land, rocks, obstructions, shoreline constructions
When the alarm is activated, the source of the grounding can be confirmed by the GROUNDING
ALARM REPORT menu.
When the GROUNDING ALARM is set to ON, a warning message window is displayed. Operate it
after it agrees to the content of the warning.
Setting range (depth): 0 to 99 m, fm or ft
Initial setting: 5 m, fm or ft
Setting range (front distance): 0.25, 0.5, 1 nm or km
Initial setting: 0.25 nm or km
6.4.6
L
anguage
This function sets the language of the display text.
Selection: English, Spanish, French, Korean, Greek
6.4.7 Maintenance
This is the maintenance menu.
6.4.7.1
Simulation
This function allows the user to test and practice working with various functions such as the sounder
and plotter.
6.4.7.2
System Test
This function tests if the device is operational or not.
NOTE: The GROUNDING ALARM function only operates with the new C-CARDs. It also affects the
speed of the redraw of the screen. If this function is not used it maybe disabled.