2
.
Exit the SERVICE PROGRAM.
Press BACKSPACE twice
Select QUIT ML2000 SERVICE MODE ............................................... press ENTER
Select Quit the program ............................................................................ press ENTER
5. DISABLE INTERFACE (ML2000 P only)
Purpose:
NOTE
Use this PARAMETER during service only.
It allows to run the ML2000 P with the FILM CHUTE out. This feature is important when you
want to observe the function of the FILM POCKET.
ML2000 P with FILM CHUTE in place ....................................................00h
ML2000 P without FILM CHUTE ..............................................................AAh
1
.
Disable the FILM CHUTE.
Start the SERVICE PROGRAM
Select SERVICE MODE from the GLOBAL MENU .......................... press ENTER
ENTER SERVICE MODE MESSAGE is displayed ............................ press ENTER
UNIT DATA are displayed....................................................................... press ENTER
Select CHANGE ML2000 DATA from the MAIN MENU ............... press ENTER
Select CHANGE PARAMETER .............................................................. press ENTER
Select DISABLE INTERF ....................................................................... press ENTER
Key in AA .................................................................................................... press ENTER
Select STORE PARAMETER .................................................................. press ENTER
2
.
Exit the SERVICE PROGRAM.
Press BACKSPACE twice
Select QUIT ML2000 ERVICE MODE ................................................. press ENTER
Select Quit the program ............................................................................ press ENTER
NOTE
Do not forget to set this PARAMETER to 00 before you hand over the ML2000 P to the customer.
6. CASS OPEN RETURN
Purpose:
It can be selected if an empty CASSETTE is returned opened or closed. The preferred
setting is CLOSED.
Empty CASSETTE returned closed.............................................................00H
Empty CASSETTE returned open ...............................................................01H
SM 3477
PARAMETER
KODAK AG, Stuttgart
4-5
6/1997
Содержание Miniloader 2000 P
Страница 6: ...TABLE OF CONTENTS SM 3477 6 1997 IV KODAK AG Stuttgart ...
Страница 10: ...TOOLS SM 3477 4 1997 1 2 KODAK AG Stuttgart ...
Страница 46: ...REPLACEMENTS SM 3477 6 97 2 36 KODAK AG Stuttgart ...
Страница 104: ...PARAMETER SM 3477 6 1997 4 10 KODAK AG Stuttgart ...
Страница 112: ......