2. ADDITIONAL STEPS
PURPOSE:
To achieve good contact between MAGAZINE SUCKERS and the top FILM in the
MAGAZINE. This PARAMETER gives the number of additional steps after the FILM PIN
reached the top FILM in the MAGAZINE. This ensures that the SUCKERS are in close
contact with the top FILM.
NOTE
If too many ADDITIONAL STEPS are used PRESSURE MARKS on the FILM may show up.
1 increment = 0.09mm
RANGE: ...........................................................................................................0h...1Eh
DEFAULT: ......................................................................................................0Ah
1
.
Change the PARAMETER ADDITIONAL STEPS.
Start the SERVICE PROGRAM
Select SERVICE MODE from the GLOBAL MENU .......................... press ENTER
ENTER SERVICE MODE MESSAGE is displayed ............................ press ENTER
UNIT DATA are displayed....................................................................... press ENTER
Select CHANGE ML2000 DATA from the MAIN MENU ............... press ENTER
Select CHANGE PARAMETER .............................................................. press ENTER
Select ADDITIONAL STEPS ................................................................ press ENTER
Key in the new value.................................................................................. press ENTER
Select STORE PARAMETER .................................................................. press ENTER
2
.
Exit the SERVICE PROGRAM.
Press BACKSPACE twice
Select QUIT ML2000 SERVICE MODE ............................................... press ENTER
Select Quit the program ............................................................................ press ENTER
3. LOWER POCKET
PURPOSE:
To place the unexposed FILM correctly into the CASSETTE.
Additional down-steps for the FILM POCKET SUCKER BAR into the CASSETTE. It prevents
the unexposed FILM from floating out of the CASSETTE.
1 increment = 0.09mm
RANGE: ...........................................................................................................0h...64h
DEFAULT: ......................................................................................................2Ah
1
.
Change the PARAMETER LOWER POCKET ST.
Start the SERVICE PROGRAM
Select SERVICE MODE from the GLOBAL MENU .......................... press ENTER
SM 3477
PARAMETER
KODAK AG, Stuttgart
4-7
6/1997
Содержание Miniloader 2000 P
Страница 6: ...TABLE OF CONTENTS SM 3477 6 1997 IV KODAK AG Stuttgart ...
Страница 10: ...TOOLS SM 3477 4 1997 1 2 KODAK AG Stuttgart ...
Страница 46: ...REPLACEMENTS SM 3477 6 97 2 36 KODAK AG Stuttgart ...
Страница 104: ...PARAMETER SM 3477 6 1997 4 10 KODAK AG Stuttgart ...
Страница 112: ......