6. PREVENTIVE MAINTENANCE
NOTE
This procedure is only for the Miniloader part. For PROCESSOR Preventive Maintenance see
PROCESSOR Service Manual.
PREPARATION:
Ask the operator for any problems.
Remove all MAGAZINES to avoid fogging of customer films.
Remove all PANELS.
Override INTERLOCK SWITCHES.
Connect the Lap Top and start the Service Program.
GENERAL ACTIVITIES:
1
.
Analyse the last 100 malfunctions .Check all error codes that occurred very often
and ask the operator for details
(i.e., C-74, C-88, C92, C-94 etc.)
Start the SERVICE PROGRAM
Select TROUBLE SHOOTING from the GLOBAL MENU............... press ENTER
Select Malfunctions of ML2000 ............................................................... press ENTER
Use for each code the description in the Service Software or Diagnostic
Manual and step through the described actions for the possible causes.
_
Check the less frequent error codes too, they may have been created because of lost
films.
NOTE
Working through the error code list is the most essential activity of the MULTILOADER
preventive maintenance. Always follow the activities mentioned in the Diagnostics Manual
or Service Software, even if it seems to be an operator caused malfunction.
2
.
Exit the SERVICE PROGRAM
Press Escape until the Main Menu Trouble Shooting is reached
Select Quit Trouble Shooting ................................................................... press ENTER
Select Quit the program ............................................................................ press ENTER
SM 3477
PREVENTIVE MAINTENANCE
KODAK AG, Stuttgart
6-1
6/1997