WOOD BURNING BOILER COOKER ALTEA 110 SICURO TOP
15
EN - Rev. 1.2
-
Thermometer
(indicates the temperature of the water inside the boiler unit);
-
Acoustic alarm
(activated whenever the boiler water temperature reaches 90-95°C);
-
Level switch
(indicates that water is not up to level inside the boiler).
Two cables exit the control unit, one of which has no plug. The cable with the plug should be connected to a mains
socket with the specifications detailed above. The insulated cable with 4 wires should be connected to the motorised
three-way valve installed in the domestic water system
(see section “
Control of a possible three-way motorised valve for
the DHW system”
).
The control unit has an internal fuse
T 3,15A.
DESCRIPTION OF THE KEYS
-
P1 ON/OFF
this button, when pressed for two consecutive seconds, switches the control unit on/off, depending on whether it is off or
on respectively.
During normal operation of the appliance, the control unit must ALWAYS be switched on.
-
P2 DECREASE TEMPERATURE
Depending on which thermostat is selected, it decreases the value set.
If pressed at the same time as P3, it activates the
DHW
function.
-
P3 INCREASE TEMPERATURE
Depending on which thermostat is selected, it increases the value set.
If pressed at the same time as P2, it activates the
DHW
function.
-
P4 SET/MENU
Provides access to the set thermostat values signalled by the associated PUMP / VALVE / AUX / SERV LEDs flashing.
It also allows you to save changes made to the values for each thermostat.
P1
P2
P3
P4
L1
L2
L3
L4
L7
L8
L5
L6
Содержание ALTEA 110
Страница 1: ...ENGLISH Wood burning boiler cooker ALTEA 110 SICURO TOP INSTALLATION USE MAINTENANCE AND HELPFUL TIPS ...
Страница 2: ......
Страница 11: ...WOOD BURNING BOILER COOKER ALTEA 110 SICURO TOP 8 EN Rev 1 2 Overall dimensions ...
Страница 39: ...WOOD BURNING BOILER COOKER ALTEA 110 SICURO TOP 36 EN Rev 1 2 ...
Страница 40: ...Cod CS IST ALT110TOP EN KLOVER Srl Via A Volta 8 37047 San Bonifacio VR VAT No 02324280235 www klover it ...