WOOD BURNING BOILER COOKER ALTEA 110 SICURO TOP
14
EN - Rev. 1.2
The outlet height (where height refers to the top of the flue, regardless of any chimney stacks) must be outside of the so-
called reflux zone, in order to prevent the formation of counter-pressures preventing the free discharge of combustion
by-products into the atmosphere.
It is therefore necessary that the minimum heights - indicated in the following diagrams - are observed:
ELECTRICAL CONNECTION
The electric connection must only be performed by
qualified staff,
in compliance with all general and local safety
standards.
Check that the power supply voltage and frequency correspond to 230V
–
50 Hz.
The appliance's safety is ensured when it is properly connected to an efficient earthing system.
In the electric connection to the mains power supply, include a 6 A
–
Id 30 mA differential trip-switch with suitable
breaking load. The electric connections, including the earth connection, must be made after shutting off the electrical
system.
When completing the system, bear in mind that the cables must be laid in an unmovable manner and far from parts
subject to high temperatures. During the final wiring of the circuit,
only use components with a suitable electrical
protection rating. Do not pass electric cables in the immediate vicinity of the flue gas pipe, unless they are insulated with
suitable materials. Connection to the mains power supply should only be carried out after the wires have been connected
to the terminal board.
KLOVER srl declines all responsibility for injury to persons and animals or damage to objects due to failure to
connect the appliance to earth or to comply with IEC specifications.
Electronic control unit
The electric control unit installed on the appliance controls the heating pump, switches the motorised three-way valve
fitted on the water system, switches the heat generator ON and OFF (if installed) and starts any additional pumps.
It is composed of:
-
Master switch
(used to supply power to the control unit itself);
-
Pump adjustable thermostat
(used to activate or deactivate the pump on reaching, or not, the temperature we set
on the thermostat itself);
-
Valve adjustable thermostat
(used to exchange any motorised valve on reaching, or not, the temperature we set on
the thermostat itself. It is normally used for DHW in combination with another heat generator);
-
AUX adjustable thermostat
(used to control whether or not the heat generator reaches the temperature set on the
thermostat);
-
SERV adjustable thermostat
(used to activate or deactivate an additional pump on reaching, or not, the
temperature set on the thermostat);
Содержание ALTEA 110
Страница 1: ...ENGLISH Wood burning boiler cooker ALTEA 110 SICURO TOP INSTALLATION USE MAINTENANCE AND HELPFUL TIPS ...
Страница 2: ......
Страница 11: ...WOOD BURNING BOILER COOKER ALTEA 110 SICURO TOP 8 EN Rev 1 2 Overall dimensions ...
Страница 39: ...WOOD BURNING BOILER COOKER ALTEA 110 SICURO TOP 36 EN Rev 1 2 ...
Страница 40: ...Cod CS IST ALT110TOP EN KLOVER Srl Via A Volta 8 37047 San Bonifacio VR VAT No 02324280235 www klover it ...