49
Max. radial force (20 mm from flange)
Nm
250
Maximum axial force
Nm
60
MRHX-3P04N-03C5
Torque
Nm
4.0
Power
W
110
Weight
kg
≈ 3.5 kg
Protection
IP
54
Operating temperature
O
C
-40
O
C / +40
O
C
Storage temperature
O
C
-40
O
C / +70
O
C
Dimensions
mm
85 x 85 x 97
Shaft dimension
mm
12
Cable length
M
0,3
Max. radial force (20 mm from flange)
Nm
250
Maximum axial force
Nm
60
MRHX-3P08N-03C5
Torque
Nm
8.0
Power
W
220
Weight
kg
≈ 5 kg
Protection
IP
54
Operating temperature
O
C
-40
O
C / +40
O
C
Storage temperature
O
C
-40
O
C / +70
O
C
Dimensions
mm
85 x 85 x 156
Shaft dimension
mm
12
Cable length
M
0,3
Max. radial force (20 mm from flange)
Nm
250
Maximum axial force
Nm
60
MRHX-3P014N-03C5
Torque
Nm
14.0
Power
W
690
Weight
kg
≈ 13,2 kg
Protection
IP
54
Operating temperature
O
C
-40
O
C / +40
O
C
Storage temperature
O
C
-40
O
C / +70
O
C
Dimensions
mm
134 x 134 x 170
Shaft dimension
mm
19
Cable length
M
0,3
Max. radial force (20 mm from flange)
Nm
250
Maximum axial force
Nm
60
The wire connecting the motor to the controller is supplied
with a pre-mounted 4-pole connector (Tyco MATE-N-LOK). The
other end of the wire is equipped with bushings and should be
connected to the drive motor terminals (U, V, W, PE).
Rys. Nr 39
Motor/regulator supply wire
For other information on power supply, Modbus control, register
list, first start and troubleshooting, see „Drives and electronics for
rotary exchangers” DTR_EVO_RR_CS_057.x.x.
4.7.2 Tension of the drive belt of the rotary exchanger
Tension the drive belt by pressing with a moderate finger
strap at a distance of about 100mm from the axis of the
pulley. The belt deflee should be 15-30mm – as in the dia-
gram below.
In case of deflection the belt should be shorten.
Fig. No 40
Drive belt adjustment
4.7.3 Operation of the rotary exchanger
The rotary exchanger should be inspected every 6/12
months. Aluminium laths get dirty.
Before cleaning rotary exchanger sections, the neighbo-
uring sections should be secured.
Clean with a vacuum cleaner with a soft suction nozzle on
the side of air inlets or blow through with air in the direc-
tion opposite to the airflow in the exchanger. The drive
belt of the rotary exchanger is an operating element and
should be replaced if an incorrect tension is noticed.
The rotary exchanger in the standard version of the unit is
equipped with a spare belt. If the exchanger design does
not include a spare rotor drive belt, contact service to de-
termine its type and proper length.
4.8 PR cross-flow exchanger / CPR high efficiency hybrid heat re-
covery system
The cross-exchanger allows heat recovery from the outlet
air with an efficiency of up to 75% and the high efficiency
hybrid kit up to 92%.
The main components are: cross-flow exchanger or hybrid
exchanger, by-pass, two-section damper, condensate tray
and condenser. The cross-flow exchanger is made of thin
extruded aluminium plates, which form ducts for supply
and exhaust air. The flow of warm air extracted from the
room, flows through the ducts of the exchanger, heating its
plates. The intake air stream flows in a perpendicular direc-
tion to the outlet air stream, taking heat from the exchanger
plates.
Heat recovery on the cross-flow exchanger does not require
any energy supply from outside, the exchanger has no mo-
ving parts, which ensures its high reliability. The intake and
outlet air streams are separated from each other. The inter-
nal tightness is determined at 99.5-99.9%
Содержание EVO-S COMPACT
Страница 2: ...SERWIS SERVICE 4858 7839950 51 48 510098081 serwis klimor com...
Страница 30: ...SERWIS SERVICE 48 587839950 51 48 510098081 seriws klimor com...
Страница 58: ...SERWIS SERVICE 48 587839950 51 48 510098081 serwis klimor com...
Страница 59: ...EVO S COMPACT KLIMOR...
Страница 65: ...63 7 8 9 10 11 50 DN40 11...
Страница 67: ...65 b 200x200 16 17 16 17 c 200x200 300x200 18 18 3 2 2 EVO 2000 5100 5610 19 13 M12 M12 M12 19...
Страница 68: ...66 EVO S CO CT 2900 a 50 20 b 150 21 c 22 2900 b c...
Страница 69: ...67 3 3 23 13 24 5100 0720 25 26 3 4 3 4 1 110 3 4 2 7 kW 3 3 15 15 30 30 P 11 P 16 P 21 P 29 3 4 8...
Страница 75: ...73 31 32 30 10 20 1 100 C 2 3 32 4 5 DX 0 03 4 5 2 12 12 4 5 3 DX...
Страница 76: ...74 EVO S CO CT CHA 4 5 4 34 4 5 5 35 4 5 6 DX 36 DX MHA...
Страница 81: ...79 5 6 6 1 KT 7 EVO wzgl dnie zmia 11 PN EN13779 2008 12 2000 24 4000 24 4000 6 12 plug fan 30 C 130 C 4...
Страница 82: ...80 EVO S CO CT 8 19 1 2 3 DX 4 5 6...
Страница 84: ...82 EVO S CO CT c IP54 d e 41 1 1 42 f A IP65...
Страница 85: ...83 11...
Страница 86: ...SERWIS SERVICE 48 587839950 51 48 510098081 serwis klimor com...
Страница 87: ......